Solo 330 | Aerosol Dispenser | Test Smoke & CO Detectors Up to 4″ in Diameter

SKU
SOLO330
Designed for detectors up to 4″ in diameter, the Solo 330 helps contractors clean or test smoke detectors and carbon monoxide (CO) sensors in hard-to-reach areas. When paired with Solo-brand access poles and aerosol testing products (sold separately), this tool makes it possible to spray control sprays from 10 to 30 feet away.
$299.99
SKU Design Detector Diameter
SOLO330 Spring-Loaded, UL-Listed Smoke Detector Accessory Up to 4″ (101.6 mm)
Compatible Extension Poles Solo Model Availability
Solo 100, Solo 101, Solo 108 Solo 330 Usually Ships Within 48 Hours

Solo 330 Aerosol Dispenser for Tests of Smoke Detectors and CO Sensors (Up to 4″ in Diameter)

The Solo 330 helps contractors clean or test smoke detectors and carbon monoxide (CO) sensors in hard-to-reach areas. When paired with Solo-brand access poles and aerosol testing products (sold separately), this tool makes it possible to discharge a controlled spray from 10 to 30 feet away.

Designed for detectors up to 4″ in diameter (101.6 mm), this tool uses a clear cup that surrounds sensors to introduce synthetic smoke or other materials into sensing chambers. This spring-loaded device features a hinged connection that facilitates use even with electronics mounted on sloped or angled ceilings. Each Solo 330 is listed to UL 77TL, an internationally-recognized standard for emergency signaling products and accessories.

This tool can dispense a variety of aerosols, including:

Is this a standalone tool?

No. The Solo 330 discharges aerosols using a Solo-brand extension pole. Depending on the attachments used, this tool can grasp detectors from distances of 14 to 30 feet. Available extension poles include:

These telescopic, no-climb extension poles provide convenience and safety, eliminating the need for ladders or climbing equipment.

To test smoke and CO detectors larger than 4″, consider the Solo 332, which fits devices as large as 7″ across. Additional products from Solo’s line of access and testing equipment include:

How do I use the Solo 330?

The Solo 330 slides into the end of a Solo 100, Solo 101, or Solo 108 extension pole. To attach it, follow these steps:

  • Unscrew and remove the red retainer cup at the base of the Solo 33o.
  • Place a Solo or Smoke Centurion aerosol canister into the retainer cup.
  • Thread the retainer cup and canister back into the Solo 330 until the aerosol activates—then unscrew slightly.
  • Slide the pole on the Solo 330’s handle into the extension pole. Make sure that the button on the Solo 100 springs up from the locking hole.

To clean or test detectors:

  • Use the extension pole to guide the Solo 330 to the detector.
  • Place the detector inside the dispenser’s see-through cup. 
  • Push up to discharge the aerosol.

Aerosols used to test smoke detector and carbon monoxide (CO) detectors should typically be discharged in one-second bursts. Repeat every ten seconds as needed. If the detector does not activate after five sprays, inspect and/or clean your detector and testing equipment (and replace the detector as needed).

Remember to:

  • Stand with one foot slightly in front of the other to reduce strain and improve balance.
  • Share the load with others—and take regular breaks.
  • Occasionally switch the position of the pole, holding it either on the right-hand or the left-hand side of the body.
  • Hold the pole perpendicular to the ground and stand directly under the top of the pole.
  • If this product must be held at an angle, stand no more than 5 feet away from a point directly beneath the detector.

Documentation

Learn more about Solo-brand testing equipment.

Write Your Own Review
You're reviewing:Solo 330 | Aerosol Dispenser | Test Smoke & CO Detectors Up to 4″ in Diameter