Solo 461 Cordless Heat Detector Test Kit
The Solo 461 Kit includes the 460 Head Unit, the 770 battery Batons, and the 727 Battery Charger – everything you need to be fully operational.
The Solo 460 Cordless Heat Detector Tester head unit, when paired with the Solo 770 batteries and Solo 727 battery charger, is a quick, simple, and reliable way to test the functionality of most heat detectors, including fixed-temperature, rate-of-rise, and combination detectors. Cordless heat detector testers provide free-range use with no cables, leads, or wires getting in the way. The head unit can be applied at an angle and/or paired with Solo Access Poles for heights.
The Solo 770 Battery Baton is a rechargeable 3000 mAh NiMH battery that works as a power source for the Solo 460. The 3000 mAh battery is power is comparable to those found in common smartphones and has a fast-charge time of just 90 minutes when charged with the Solo 727 Battery Charger. It has an operating temperature of 50-95F, a discharge temperature of 14-113F, and should be stored in an area with RH non-condensing 0-90% humidity at 14-120F. For optimum battery life, it is recommended that the battery is fully charged before first use, then used until completely discharged. Repeat this process for the first few uses.
The Solo 727 is a 220/240v fast battery charger for the Solo 770 Battery Batons. Using nominal 110/240VAC mains or 12VDC in-vehicle power, this product will charge a fully depleted Solo battery in 60-90 minutes. The Solo 727 has an operating temperature of 32-95F and should be stored at a humidity of RH non-condensing 0-90% at 14-120F. This charger is designed only for the Solo 760 and 770 NiMH battery batons. Do not connect other types of batteries – danger of explosion.
