Ball Drip Valve | 3/4 in. | Brass | 200 PSI

SKU:
73-LN-BALD-120000
Manufacturer Part Number:
700-150-00080
$28.71

Select Variation

  • Buy 10 - 99 and get 3% off
  • Buy 100 or above and get 10% off

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
73-LN-BALD-120000
Manufacturer:
Lansdale™
Valve Type:
Ball Drip Valve
Number of Connections:
2 Connections
Connection Type:
Iron Pipe Size (IPS)
Body Material:
Cast Brass
Other Material:
Stainless Steel Ball
Size:
3/4 in.
Size Detail:
3/4 in. IPS x 3/4 in. IPS
UL Listed:
No
FM Approved:
No
Rated Working Water Pressure:
200 PSI
Finish:
Brass
Length:
3.15 in. (80.01 mm)
Width:
1.4 in. (35.56 mm)
Height:
1.4 in. (35.56 mm)
Weight:
0.46 lb. (0.21 kg)

Ball Drip Valve | 3/4 in. | Brass | 200 PSI | Hero Image | QRFS™

Ball Drip Valve | 3/4 in. | Brass | 200 PSI | Hero Image | QRFS™
Ball Drip Valve | 3/4 in. | Brass | 200 PSI | Side Image | QRFS™
Ball Drip Valve | 3/4 in. | Brass | 200 PSI | Vertical Image | QRFS™
Ball Drip Valve | 3/4 in. | Brass | 200 PSI | Ball Image | QRFS™
Play Button
Overview

Ball Drip Valves 3/4 in. for Fire Protection Systems

This 3/4 in. IPS durable cast brass Ball Drip Valve provides reliable defense against system damage caused by ice in water-based systems, specifically fire protection/fire sprinkler systems and standpipes. With a rated working water pressure of 200 PSI, this gravity-operated valve drains the lowest system point between the Fire Department Connection (FDC) and check valve in fire protection systems, in order to prevent moisture from accumulating on the dry side of the FDC.  It features two 3/4 in. IPS connections, with a stainless-steel ball that closes the valve under pressure and prevents leaks during system activation. Gravity returns the ball to the open position as water flow stops.

Fire Protection Ball Drip Valve Options & Additional Information

This Ball Drip Valve is available in a Brass finish in 1/2 in. and 3/4 in. IPS. Visit the “product options” on this page to view all available sizes. This valve should only be installed in the horizontal position.

This product is not specifically listed by cULus, FM, or any other listing(s) organization – we recommend consulting with your local fire marshal or other authority having jurisdiction before installing.

Reviews
No reviews yet
Product Alternatives