CPVC Cement | Pint | Spears | FS5-020

SKU:
51-SP-CMNT-P
Manufacturer Part Number:
FS5-020
$35.99
  • Buy 12 - 119 and get 5% off
  • Buy 120 or above and get 10% off

FAST SHIPPING: In stock items ship SAME DAY if ordered before 3PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
51-SP-CMNT-P
Manufacturer Part Number:
FS5-020
Manufacturer:
Spears
Fitting:
Cement
Size:
Pint
Size Detail:
1 Pint
UL Listed:
Yes
FM Approved:
Yes
Rated Working Water Pressure:
175 PSI
Rated Working Temperature:
150F
Length:
3.5 in. (88.9 mm)
Width:
3.5 in. (88.9 mm)
Height:
4.5 in. (114.3 mm)
Weight:
1.5 lb. (0.68 kg)

Spears FlameGuard™ CPVC Pint Hero Image | QRFS™

Spears FlameGuard™ CPVC Pint Hero Image | QRFS™
Spears FlameGuard™ CPVC Pint Label 1 | QRFS™
Spears FlameGuard™ CPVC Pint Label 2 | QRFS™
Spears FlameGuard™ CPVC Pint Top Image | QRFS™
Play Button
Overview

Spears FlameGuard™ CPVC One-Step Cement

CPVC Glue forms a water-tight seal between CPVC pipes, fittings, couplings, elbows, and other components used in the construction of fire sprinkler systems. This one-step solvent cement softens the surface of CPVC pipe and fittings to form a secure and reliable bond.

Spears FlameGuard™ CPVC cement should only be used with Spears FlameGuard™ pipe and fittings. Intermixing CPVC brands can void the manufacturer’s warranty or pose a serious fire hazard. Review the Spears Compatible Products List below or visit Spears website to ensure compatibility with other products. Only install in accordance with the Spears Installation Guide linked below.

For best results, choose an applicator with a width about half the size of the pipe's diameter. This solvent cement is listed by NSF for use in potable water systems.

Curing times vary with the selected pipe size, ambient temperature, and test pressure.

This CPVC Cement is available in a Pint or a Quart. You can select your preferred size from the “Options” section at the top of this product page.

Spears is a leader in the CPVC fire sprinkler pipe market. Their fire sprinkler CPVC products provide a clean, consistent connection for optimal water flow when used with Spears FlameGuard™ pipe.

Spears FlameGuard™ CPVC One-Step Cement Listings, Approvals, and Installation

This One-Step CPVC Cement is made in the USA by Spears, a California-based manufacturer of plumbing and fire sprinkler pipe fittings with over 50 years’ experience. This cement has a working pressure rating of 175 PSI at 150F (65C). It is intended for use in light hazard NFPA 13 occupancies, residential NFPA 13R occupancies, and home fire sprinkler systems in accordance with NFPA 13D, when approved by the local Authority Having Jurisdiction. This product is UL, FM, and LPCB approved.

Spears FlameGuard™ CPVC One-Step Cement Warnings and Other Information

DO NOT expose Spears FlameGuard™ CPVC Fire Sprinkler Products to edible oils, esters, ketones, or petroleum-based products, such as cutting oils, packing oils, traditional pipe thread pastes or dopes, and some lubricants. Do not store or install CPVC products in direct contact with plasticizer containing materials such as electrical tape or certain wire and cable insulations. Consult with the chemical manufacturer for compatibility with CPVC or Spears before use. Contact with incompatible chemicals could cause serious personal injury, property damage, and product damage.

Spears FlameGuard™ CPVC Fire Sprinkler Products should be stored indoors with a maximum storage temperature of 110° F (43° C). If storing outdoors, the products must be covered with a non-transparent material to prevent extended exposure to sunlight. Brief exposure to direct sunlight on the job site may result in color fade, but it will not affect the physical properties. Spears FlameGuard™ CPVC Fire Sprinkler Fittings should be stored indoors in their original containers to keep them free from dirt and to help reduce the possibility of damage.

Spears FlameGuard™ CPVC Fire Sprinkler Products must no­t be subjected to prolonged sunlight exposure. The use of pipe and fittings that have been damaged due to improper storage could cause serious personal injury, property damage, and product damage.

Spears FlameGuard™ are registered trademarks of the Spears Manufacturing Company. All rights reserved.

Reviews
No reviews yet
Product Alternatives