Looking for the right fire sprinkler escutcheon for your sprinkler? Check out this FREE guide.

Everlux Photoluminescent EXIT Sign | Red on White | 16″ x 9″ | C0012 | UL-Listed

SKU
C0012
Everlux’s self-illuminated aluminum exit sign features red letters on a white 16″ x 9″ background. This sign is coated with a photoluminescent pigment, and comes standard with four mounting holes, mounting equipment, and self-adhesive directional arrows.
$109.95
  • Buy 2 for $106.65 each and save 3%
  • Buy 10 for $104.45 each and save 5%
  • Buy 50 for $98.96 each and save 10%
SKU Construction Finish
C0012 1 /32″ Thick Aluminum (1mm) Photoluminescent Pigment (Red on White)
Dimensions Accessories Included
15-3/4″ x 9-3/8″ (400 mm x 240 mm) Directional Chevrons, Four Plugs, and Four Bolts
Listings & Approvals Everlux Part No. Availability
UL924, ASTM E2072 C0012 Usually Ships Within 48 Hours

16″ x 9″ Everlux Photoluminescent Exit Sign (Red Text on White Back)

The Red-on-White Everlux Photoluminescent Exit Sign supplies commercial, industrial, and large residential buildings with an alternative to powered exit signage. This code-compliant, listed sign does not require electricity and can guide occupants to safety during a power outage or natural disaster.

This Everlux sign features photoluminescent red text on a white plate measuring approximately 16″ x 9″ (400 mm x 240 mm). Molded from aluminum and coated in a glow-in-the-dark pigment, this sign provides a minimum of 90 minutes’ illumination visible at a distance of 50 feet.

How does this sign work?

This red-and-white exit sign glows after sufficient exposure to light. Note, however, that the “reliable light source” required by life safety codes typically can’t be natural lighting. Every photoluminescent sign needs illumination from an external charging light. Local fire codes may require that the charging light is on 24/7, while the building is occupied, or at other times. Always check with your local AHJ.

In compliance with UL 924, this sign will provide a minimum of 20 millicandelas per square meter (mcd/m²) when charged—enough light to be seen and understood from 50 feet away.

Each sign can fully charge in 60 minutes when provided with a light source delivering:

  • 54 lux (or 5 footcandles) of light
  • A cool white source color (4000K)

These required levels of light may be provided by fluorescent and LED lights with a cool-white color temperature. These lights are bright and typically reserved for indoor walkways and workspaces. Other types of lighting—even very bright incandescent (traditional) bulbs or neon signs—shouldn’t be used as external charging lights.

When can I use a photoluminescent exit sign?

Modern building codes require exit signs in schools, commercial structures, and a variety of other structures where a power outage may impede the safe and swift exit of occupants. NFPA 101: Life Safety Code and the International Building Code permit the use of photoluminescent signs so long as they comply with:

  • UL 1994: Standard for Luminous Egress Path Marking Systems
  • ASTM E 2072: Standard Specification for Photoluminescent (Phosphorescent) Safety Markings
  • Local rules established by the authority having jurisdiction (AHJ), in NFPA 101-compliant facilities

This red-and-white Everlux exit sign also complies with NFPA 101 by providing:

  • Letters at least 6″ tall and 3/4″ wide
  • Chevron-type directional indicators
  • UL 1994-compliant illumination

These signs are often mounted in locations where electricity is inaccessible. Local codes may also require door-mounted markers that supplement traditional exit signs, particularly in high-rise buildings.

How can I install this exit sign?

This single-sided Everlux red-on-white exit sign is designed for surface mounting on a wall, ceiling, or “flag”. To complete this, the sign is supplied with four mounting holes, four plugs, and four bolts to safely and firmly plant the sign into the wall.

The red letters and white background are visible from 45 degrees to the left or right of the sign’s center, for a total viewing area of 90 degrees. This sign includes four self-adhesive directional chevrons (arrows) that allow installers to indicate the exit path.

Contractors can also purchase one of Everlux’s 16″ x 9″ aluminum frames (available by special order at 888-361-6662), including:

  • Standard slide-in aluminum frames with screws, plugs, and hardware for ceiling or wall-mounting (L 06 11)
  • Self-adhesive wall-mounted aluminum frames (L 60 21)
  • Pre-fitted slim aluminum frames – must supply your own adhesive/double-sided tape (L 60 22)

Documentation

Click here to view the manual for this Everlux Photoluminescent EXIT Sign (16″ x 9″).

Write Your Own Review
You're reviewing:Everlux Photoluminescent EXIT Sign | Red on White | 16″ x 9″ | C0012 | UL-Listed
Your Rating