SALE

Glow-in-the-Dark Fire Hose Sign | White Arrow and Pictogram on Red | 16 in. x 4 in.

SKU:
L1112
$12.48
$8.74
6 UNITS IN STOCK
Special Pricing
  • Buy 10 - 99 and get 5% off
  • Buy 100 or above and get 15% off

FAST SHIPPING: In stock items ship SAME DAY if ordered before 3PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications

Glow-in-the-Dark Fire Hose Sign | White Arrow and Pictogram on Red | 16 in. x 4 in.

Glow-in-the-Dark Fire Hose Sign | White Arrow and Pictogram on Red | 16 in. x 4 in.
Glow-in-the-Dark Fire Hose Sign | White Arrow and Pictogram on Red | 16 in. x 4 in.
Overview
SKU Construction Finish
L1112 Vinyl Photoluminescent Pigment (White on Red)
Dimensions Listings & Approvals
15-3/4in. x 3-15/16in. (400 mm x 100 mm) ASTM E2072
Everlux Part No. Availability
L1112 Usually Ships Within 48 Hours

Everlux Glow-in-the-Dark Fire Hose Arrow Sign

This White-on-Red Fire Hose Arrow sign guides a building's occupants to the location of indoor fire hoses used with standpipe systems. These signs glow in the dark without electricity using photoluminescent white text and symbols on a vertical vinyl signmeasuringapproximately16 in.x4 in.(400mmx100mm).

Each of these glow-in-the-dark fire hose arrow signs provides:

  • A minimum of 90 minutes' illumination
  • A universal pictogram (symbol) of a fire hose
  • The text ‚àö√⬨¬¢fire hose‚àö√⬨¬¢
  • One long vertical arrow designed for installation above the hose

Manufactured by Everlux, a world-renowned maker of safety signage, this glow-in-the-dark sign features a photoluminescent body, clear symbols, and high-contrast text. The pigment provides 90 minutes' illumination after sufficient exposure to light in accordance with ASTM-E2072, ASTM International's testing standard for photoluminescent markings.

How does this fire hose sign work?

Everlux's white-on-red fire hose arrow sign glows after sufficient exposure to light. Note, however, that the âreliable light sourceâ required by life safety codes typically can't be natural lighting. Every photoluminescent sign needs illumination from an external charging light to glow in accordance with their standards or listings.

This sign will provide a minimum of 5.5 millicandelas per square meter (mcd/m²) when charged. Each sign can fully charge in 60 minutes when provided with a light source delivering:

  • 11 lux (or 1 footcandle) of light
  • A cool white source color (4000K)

These required levels of light may be provided by fluorescent and LED lights with a cool white color temperature. These lights are bright and typically reserved for indoor walkways and workspaces. Other types of lighting,¬ùeven very bright incandescent (traditional) bulbs or neon signs,¬ùshouldn't be used as external charging lights.

Where and how should I install this fire hose arrow?

This single-sided, low-maintenance Everlux white-on-red fire hose arrow sign is designed for surface mounting on a wall. With this standalone sign, installers can either:

  • Place heavy-duty, double-sided sign tape (or a similar adhesive) on the back of the sign
  • Use drywall screws or other sign-mounting hardware, mounting along the sign's border as needed
Reviews
No reviews yet