Reliable™ RA1325 Upright Sprinkler | SR | 5.6K | Chrome | 175F | F56U5CN

SKU:
RA1325CH175
Manufacturer Part Number:
F56U5CN
$17.65
Data Sheet Product Data Sheet

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
RA1325CH175
Manufacturer Part Number:
F56U5CN
Manufacturer:
Reliable™
SIN:
RA1325
Model:
F1-56 Upright
Head Type:
Upright
Finish:
Chrome
Finish Detail:
Chrome
Size:
1/2 in.
Size Detail:
1/2 in. NPT Sprinkler
K Factor:
5.6K
Response Type:
Standard Response (SR)
Temperature:
175F
Heat Element:
Glass Bulb
Coverage:
Standard Coverage
Material:
Brass Frame, Brass/Bronze Deflector
Corrosion Resistant:
No
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
Yes
Occupancy Type:
Light/Ordinary Hazard
Maximum Working Water Pressure:
250 PSI
Sourced Location:
USA
Length:
1.25 in. (31.75 mm)
Width:
1.25 in. (31.75 mm)
Height:
2.30 in. (58.42 mm)
Weight:
0.16 lbs. (0.07 kg)
System Type:
Wet

Reliable™ RA1325 Upright Sprinkler | SR | 5.6K | Chrome | 175F | F56U5CN | QRFS™ | Hero

Reliable™ RA1325 Upright Sprinkler | SR | 5.6K | Chrome | 175F | F56U5CN | QRFS™ | Hero
Reliable™ RA1325 Upright Sprinkler | SR | 5.6K | Chrome | 175F | F56U5CN | QRFS™ | Front
Reliable™ RA1325 Upright Sprinkler | SR | 5.6K | Chrome | 175F | F56U5CN | QRFS™ | Deflector
Overview

Reliable™ Model F156 Standard Response Upright (RA1325) Fire Sprinkler Head

Sprinkler Identification Number (SIN): RA1325

This upright sprinkler features a Chrome finish and 175F (79C) temperature.

This Reliable™ Model F156 Upright Fire Sprinkler is a standard coverage upright fire sprinkler head, activating at 175F (79C) with a 5.6 K-Factor, and is rated for Light and Ordinary Hazard occupancies. Each upright head features a heat-sensitive glass bulb assembly, standard 1/2 in. NPT threads, and a brass frame with a brass/bronze deflector.

This is a standard response, standard coverage, upright sprinkler with a maximum working water pressure of 250 PSI (17 BAR). The RA1325 Model F156 Sprinkler features a durable and low-profile appearance.

Using a heat-activated glass bulb assembly, this automatic fire sprinkler opens when ambient temperatures reach 175F (79C), drenching the area surrounding a fire to keep it in its place of origin. The RA1325 is installed upright or intermediate upright. Refer to the manufacturer data sheet for installation instructions with the approved Reliable™ accessories.

Reliable™ Model F156 Fire Sprinkler RA1325 Sprinkler Head Listings and Approvals

Each F156 sprinkler is made by Reliable™, a global leader in fire protection manufacturing for over 100 years. When installed properly, this RA1325 fire sprinkler head maintains listings and approvals: cULus Listed, FM Approved, LPCB, VdS, EC, UKCA
Refer to the datasheet for listings and approvals in specific temperatures and/or applications.

When using Reliable™ Upright Sprinkler RA1325 for systems designed to NFPA 13, apply the listed areas of coverage and minimum water supply requirements shown in the manufacturer datasheet. This upright sprinkler head has a maximum working pressure of 250 PSI (17 BAR) and connects to wet piping systems.

Reliable™ F156 (RA1325) Upright Sprinkler Installation and Other Information

During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional installation and storage information.

Available finish options include Brass, Chrome, and White. White Polyester Finish (White is UL Listed as corrosion resistant. Temperature options include 135F (57C), 155F (68C), 175F (79C), 200F (93C), 286F (141C), 360F (182C), and 500F (260C). Finish and temperature combinations available in the “Options” section at the top of this product page.

The RA1325 listed wrenches include the approved Reliable™ Model W2, Model W14 (New frame with guard installed), and Model W13 (Legacy frame with guard installed). Add the correct wrench for your RA1325 installation. Sprinklers with Legacy frames require an alternative W13 wrench for proper installation.

Other listed accessories include Reliable™ sprinkler head guards and water shields, listed below and available at the top of this page. Prevent accidental activation or damage to your RA1325 sprinkler by installing the appropriate head guard and ensure the timely activation of your intermediate upright sprinkler head by installing an appropriate water shield. Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page.

Available Reliable™ RA1325 Upright Sprinklers:

Brass:
RA1325 Upright Sprinkler | SR | 5.6K | Brass | 135F | F56U0BN
RA1325 Upright Sprinkler | SR | 5.6K | Brass | 155F | F56U1BN
RA1325 Upright Sprinkler | SR | 5.6K | Brass | 175F | F56U5BN
RA1325 Upright Sprinkler | SR | 5.6K | Brass | 200F | F56U2BN
RA1325 Upright Sprinkler | SR | 5.6K | Brass | 286F | F56U3BN
RA1325 Upright Sprinkler | SR | 5.6K | Brass | 360F | F56U6BN

Chrome:
RA1325 Upright Sprinkler | SR | 5.6K | Chrome | 135F | F56U0CN
RA1325 Upright Sprinkler | SR | 5.6K | Chrome | 155F | F56U1CN
RA1325 Upright Sprinkler | SR | 5.6K | Chrome | 175F | F56U5CN
RA1325 Upright Sprinkler | SR | 5.6K | Chrome | 200F | F56U2CN
RA1325 Upright Sprinkler | SR | 5.6K | Chrome | 286F | F56U3CN
RA1325 Upright Sprinkler | SR | 5.6K | Chrome | 360F | F56U6CN

White:
RA1325 Upright Sprinkler | SR | 5.6K | White | 135F | F56U0WN
RA1325 Upright Sprinkler | SR | 5.6K | White | 155F | F56U1WN
RA1325 Upright Sprinkler | SR | 5.6K | White | 175F | F56U5WN
RA1325 Upright Sprinkler | SR | 5.6K | White | 200F | F56U2WN
RA1325 Upright Sprinkler | SR | 5.6K | White | 286F | F56U3WN
RA1325 Upright Sprinkler | SR | 5.6K | White | 360F | F56U6WN

Wrench:

W-2 Fire Sprinkler Wrench | WW2
W-14 Fire Sprinkler Wrench | W14 | New frame with guard installed
W-13 Fire Sprinkler Wrench | W13 | Legacy frame with guard installed

Guards & Shields (New Frames):
Factory Water Shield (cULus, FM)
F-1 Guard (cULus, FM)
F-3 Guard with Shield (cULus, FM)

Guards & Shields (Legacy Frames):
Factory Water Shield
C-1 Guard (FM)
C-3 Guard with Shield (cULus, FM)
D-1 Guard (cULus)
D-3 Guard with Shield (cULus)

Reviews
No reviews yet
Product Alternatives