*OBSOLETE*Tyco™ TY3151 Upright Sprinkler | SR | 5.6K | Chrome | 200F | 57-570-9-200

SKU:
TY3151CH200
Manufacturer Part Number:
57-570-9-200
$22.79

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
TY3151CH200
Manufacturer Part Number:
57-570-9-200
Manufacturer:
Tyco™
SIN:
TY3151
Model:
TY-B
Head Type:
Upright
Finish:
Chrome
Finish Detail:
Chrome Plated
Size:
1/2 in.
Size Detail:
1/2 in. NPT
K Factor:
5.6K
Response Type:
Standard Response (SR)
Temperature:
200F
Heat Element:
Glass Bulb
Coverage:
Standard Coverage
Material:
Bronze Frame, Copper Deflector
Corrosion Resistant:
No
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
Yes
Other Listings:
EAC Approved, LPCB, VdS Approved
Maximum Working Water Pressure:
175 PSI
Sourced Location:
USA
Length:
1.69 in. (42.926 mm)
Width:
1.69 in. (42.926 mm)
Height:
2.25 in. (57.15 mm)
Weight:
0.16 lbs. (0.07 kg)

Tyco™ TY3151 Chrome 200F SR Upright 57-570-9-200 Hero Image | QRFS™

Tyco™ TY3151 Chrome 200F SR Upright 57-570-9-200 Hero Image | QRFS™
Tyco™ TY3151 Chrome 200F SR Upright 57-570-9-200 Side Image | QRFS™
Tyco™ TY3151 Chrome 200F SR Upright 57-570-9-200 Alt Side Image | QRFS™
Tyco™ TY3151 Chrome 200F SR Upright 57-570-9-200 Deflector Image | QRFS™
Overview

The TY3151 is now obsolete. It has been replaced by the TY315.

Tyco Model TY-B Upright Fire Sprinkler Head

Sprinkler Identification Number (SIN): TY3151

This Upright sprinkler features a Chrome finish and a 200°F (93°C) temperature.

This Tyco Model TY-B Upright Fire Sprinkler is a standard response, standard coverage sprinkler, activating at 200°F with a 5.6 K-Factor. Each upright head features a heat-sensitive 5 mm glass bulb, Standard 1/2 in. NPT threads, and a Bronze frame with Copper deflector.

This is a standard response, standard coverage, upright sprinkler with a maximum working water pressure of 250 PSI. Using a heat-activated glass bulb, this automatic fire sprinkler opens when ambient temperatures reach 200°F, effectively containing the spread of fire.

The TY3151 is installed in the upright position. Refer to the manufacturer data sheet for installation instructions.

Tyco Upright Fire Sprinkler (TY3151) Sprinkler Head Listings and Approvals

Each sprinkler head is made by Tyco, a global leader in fire protection manufacturing for nearly 100 years. When installed properly, this TY3151 maintains the following listings and approvals: UL, C-UL, FM, LPCB, EAC
Refer to the datasheet for listings and approvals in specific temperatures and/or applications.

The Tyco Upright Sprinkler TY3151 is designed for NFPA 13. Apply the listed areas of coverage and minimum water supply requirements as shown in the datasheet. This Upright sprinkler head has a maximum working pressure of 250 PSI (17.2 BAR) and connects to wet pipe fire protection systems.

Tyco TY3151 Automatic Fire Sprinkler Installation and Accessories

During installation, be aware that over-tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer-approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional installation and storage information.

Listed TY3151 Accessories include:

Sprinkler Wrenches:

  • W-Type 6 Standard Sprinkler Wrench

Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These are available in the corresponding product category sections.