*OBSOLETE*Tyco™ TY3251 Pendent Sprinkler | SR | 5.6K | Chrome | 200F | 57-571-9-200

SKU:
TY3251CH200
Manufacturer Part Number:
57-571-9-200
$12.98
Data Sheet Product Data Sheet

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
TY3251CH200
Manufacturer Part Number:
57-571-9-200
Manufacturer:
Tyco™
SIN:
TY3251
Model:
TY-B
Head Type:
Pendent
Finish:
Chrome
Finish Detail:
Chrome Plated
Size:
1/2 in.
Size Detail:
1/2 in. NPT
K Factor:
5.6K
Response Type:
Standard Response (SR)
Temperature:
200F
Heat Element:
Glass Bulb
Coverage:
Standard Coverage
Material:
Bronze Frame, Copper Deflector
Corrosion Resistant:
No
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
Yes
Other Listings:
EAC Approved, LPCB, VdS Approved
Maximum Working Water Pressure:
175 PSI
Sourced Location:
USA
Length:
1.25 in. (31.75 mm)
Width:
1.25 in. (31.75 mm)
Height:
2.25 in. (57.15 mm)
Weight:
0.13 lbs. (0.06 kg)

Tyco™ TY3251 Chrome 200F SR Pendent 57-571-9-200 Hero Image | QRFS™

Tyco™ TY3251 Chrome 200F SR Pendent 57-571-9-200 Hero Image | QRFS™
Tyco™ TY3251 Chrome 200F SR Pendent 57-571-9-200 Side Image | QRFS™
Tyco™ TY3251 Chrome 200F SR Pendent 57-571-9-200 Alt Side Image | QRFS™
Tyco™ TY3251 Chrome 200F SR Pendent 57-571-9-200 Deflector Image | QRFS™
Overview

This sprinkler head is now obsolete and is no longer being manufactured. It has been replaced by the Tyco TY325, which is a functional equivalent.

 

Tyco™ Model TY-B Pendent Fire Sprinkler Head

Sprinkler Identification Number (SIN): TY3251

This Pendent sprinkler features a Chrome finish and a 200°F (93°C) temperature.

This Tyco™ Model TY-B Pendent Fire Sprinkler is a standard response, standard coverage sprinkler, activating at 200°F with a 5.6 K-Factor. Each pendent head features a heat-sensitive 5 mm glass bulb, Standard 1/2 in. NPT threads, and a Bronze frame with Copper deflector.

This is a standard response, standard coverage, pendent sprinkler with a maximum working water pressure of 250 PSI. Using a heat-activated glass bulb, this automatic fire sprinkler opens when ambient temperatures reach 200°F, effectively containing the spread of fire.

The TY3251 is installed as a pendent using Tyco™’s approved Style 10 recessed escutcheon (if recessed installation is required). Refer to the manufacturer data sheet for installation instructions with the approved Tyco™ escutcheon(s).

Tyco™ Pendent Fire Sprinkler (TY3251) Sprinkler Head Listings and Approvals

Each sprinkler head is made by Tyco™, a global leader in fire protection manufacturing for nearly 100 years. When installed properly, this TY3251 maintains the following listings and approvals: UL, C-UL, FM, LPCB, EAC
Refer to the datasheet for listings and approvals in specific temperatures and/or applications.

The Tyco™ Pendent Sprinkler TY3251 is designed for NFPA 13. Apply the listed areas of coverage and minimum water supply requirements as shown in the datasheet. This Pendent sprinkler head has a maximum working pressure of 250 PSI (17.2 BAR) and connects to wet pipe fire protection systems.

Tyco™ TY3251 Automatic Fire Sprinkler Installation and Accessories

During installation, be aware that over-tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer-approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional installation and storage information.

Listed TY3251 Accessories include:

Recessed Escutcheons:

  • Style 10

Sprinkler Wrenches:

  • W-Type 6 Standard Sprinkler Wrench
  • W-Type 7 Recessed Sprinkler Wrench

Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These are available in the corresponding product category sections.

Available Sprinklers

This pendent sprinkler head is also available in Brass and White finishes and in 135F, 155F, 175F, 286F, and 360F temperature options.

Reviews
No reviews yet
Product Alternatives