Reliable™ R1013 Model G Pendent Sprinkler | SR | 4.2K | Chrome | 135F | GP07C

SKU:
R1013CH135
Manufacturer Part Number:
GP07C
$91.19
Data Sheet Product Data Sheet

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
R1013CH135
Manufacturer Part Number:
GP07C
Manufacturer:
Reliable™
SIN:
R1013
Model:
G Pendent
Head Type:
Pendent
Finish:
Chrome
Finish Detail:
Chrome
Size:
1/2 in.
Size Detail:
1/2 in. NPT Sprinkler
K Factor:
4.2K
Response Type:
Standard Response (SR)
Temperature:
135F
Heat Element:
Fusible Link
Coverage:
Standard Coverage
Material:
Brass Frame, Brass Deflector
Corrosion Resistant:
No
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
No
Occupancy Type:
Ordinary/Extra Hazard
Maximum Working Water Pressure:
175 PSI
Escutcheon Type:
Recessed or Surface Mounted
Sourced Location:
USA
Length:
1.25 in. (31.75 mm)
Width:
1.25 in. (31.75 mm)
Height:
2.25 in. (57.15 mm)
Weight:
0.16 lbs. (0.07 kg)
System Type:
Wet

Reliable™ R1013 Model G Pendent Sprinkler | SR | 4.2K | Chrome | 135F | GP07C | QRFS™ | Hero

Reliable™ R1013 Model G Pendent Sprinkler | SR | 4.2K | Chrome | 135F | GP07C | QRFS™ | Hero
Reliable™ R1013 Model G Pendent Sprinkler | SR | 4.2K | Chrome | 135F | GP07C | QRFS™ | Front
Reliable™ R1013 Model G Pendent Sprinkler | SR | 4.2K | Chrome | 135F | GP07C | QRFS™ | Deflector
Reliable™ R1013 Model G Pendent Sprinkler | SR | 4.2K | Chrome | 135F | GP07C | QRFS™ | Temperature Label
Overview

Reliable™ Model G Standard Response Pendent (R1013) Fire Sprinkler Head

Sprinkler Identification Number (SIN): R1013

This Pendent sprinkler features a Chrome finish and 135F (68C) temperature.

This Reliable™ Model G Pendent Fire Sprinkler is a standard coverage Pendent fire sprinkler head, activating at 135F (57C) with a 4.2 K-Factor, and is rated for Light Hazard occupancies. Each Pendent head features a heat-sensitive fusible link assembly, standard 1/2 in. NPT threads, and a brass frame with a brass deflector.

This is a standard response, standard coverage, Pendent sprinkler with a maximum working water pressure of 175 PSI (12 BAR). The R1013 Model G Sprinkler features a low profile and compact design. Using a heat-activated fusible link assembly, this automatic fire sprinkler opens when ambient temperatures reach the sprinkler’s listed activation temperature, drenching the area surrounding a fire to keep it in its place of origin.

Reliable™ Model G Fire Sprinkler R1013 Sprinkler Head Listings and Approvals

Each G sprinkler is made by Reliable™, a global leader in fire protection manufacturing for over 100 years. When installed properly, this R1013 fire sprinkler head maintains listings and approvals:
UL

Refer to the datasheet for listings and approvals in specific temperatures and/or applications.

When using Reliable™ Pendent Sprinkler R1013 for systems designed to NFPA standards, apply the listed areas of coverage and minimum water supply requirements shown in the manufacturer datasheet. This Pendent sprinkler head has a maximum working pressure of 175 PSI (12 BAR) and connects to wet piping systems.

Reliable™ (R1013) G Pendent Sprinkler Installation and Other Information

The R1013 Pendent Sprinkler is installed exposed, surface mounted, or recessed in the Pendent orientation. Refer to the manufacturer data sheet for installation instructions with the approved Reliable™ accessories. During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional installation and storage information.

Notes (From Manufacturer Datasheet):
1. 286°F (141°C) temperature rated sprinklers not approved for recessed installations.
2. FM Approval of Model G Recessed sprinkler for ordinary and extra hazard occupancies is limited to wet pipe systems only.
3. Not suitable for recessed installations.

Model G Series standard spray upright and pendent sprinklers having K-factors of 5.6 (80) and higher are permitted to be used in all occupancy classifications and building construction types unless otherwise noted. Model G Series standard spray upright and pendent sprinklers having K-factors less than 5.6 (80) are limited to light hazard occupancies.

Available finish options include Brass and Chrome.

Temperature options include 135F (57C), 165F (74C), 212F (100C), and 286F (141C). Finish and temperature combinations available in the “Options” section at the top of this product page.

The R1013 listed wrenches include the approved Reliable™ Model W2 and Reliable™ Model RC1 (recessed). Add the correct wrench for your R1013 installation.

Other listed accessories include Reliable™ sprinkler head guards and water shields, listed below and available at the top of this page. Prevent accidental activation or damage to your R1013 sprinkler by installing the appropriate head guard and ensure the timely activation of your intermediate Pendent sprinkler head by installing an appropriate water shield. Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page.

Available Reliable™ R1013 Pendent Sprinklers & Listed Accessories:

Brass Finish
Reliable™ R1013 Model G Pendent Sprinkler | SR | 4.2K | Brass | 135F | GP07B
Reliable™ R1013 Model G Pendent Sprinkler | SR | 4.2K | Brass | 165F | GP17B
Reliable™ R1013 Model G Pendent Sprinkler | SR | 4.2K | Brass | 212F | GP27B
Reliable™ R1013 Model G Pendent Sprinkler | SR | 4.2K | Brass | 286F | GP37B

Chrome Finish
Reliable™ R1013 Model G Pendent Sprinkler | SR | 4.2K | Chrome | 135F | GP07C
Reliable™ R1013 Model G Pendent Sprinkler | SR | 4.2K | Chrome | 165F | GP17C
Reliable™ R1013 Model G Pendent Sprinkler | SR | 4.2K | Chrome | 212F | GP27C
Reliable™ R1013 Model G Pendent Sprinkler | SR | 4.2K | Chrome | 286F | GP37C
Wrenches:
W-2 Fire Sprinkler Wrench | WW2 | Pendent
RC1 Fire Sprinkler Wrench | RC1 | Recessed Pendent

Recessed Escutcheons:
G (cULus, all SIN)
F1 (cULus, all SIN)

Guards & Shields:
D-1 Guard (UL)
C-1 Guard (FM)

Reviews
No reviews yet
Product Alternatives