Reliable™ R1026 Model G Upright Sprinkler | SR | 8.0K | Chrome | 135F | GU0LHC

SKU:
R1026CH135
Manufacturer Part Number:
GU0LHC
$52.19
Data Sheet Product Data Sheet

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
R1026CH135
Manufacturer Part Number:
GU0LHC
Manufacturer:
Reliable™
SIN:
R1026
Model:
G Upright
Head Type:
Upright
Finish:
Chrome
Finish Detail:
Chrome
Size:
1/2 in.
Size Detail:
1/2 in. NPT Sprinkler
K Factor:
8.0K
Response Type:
Standard Response (SR)
Temperature:
135F
Heat Element:
Fusible Link
Coverage:
Standard Coverage
Material:
Brass Frame, Brass Deflector
Corrosion Resistant:
No
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
Yes
Occupancy Type:
Light, Ordinary, Extra Hazard
Maximum Working Water Pressure:
175 PSI
Sourced Location:
USA
Length:
1.25 in. (31.75 mm)
Width:
1.25 in. (31.75 mm)
Height:
2.25 in. (57.15 mm)
Weight:
0.16 lbs. (0.07 kg)
System Type:
Wet

Reliable™ R1026 Model G Upright Sprinkler | SR | 8.0K | Chrome | 135F | GU0LHC | QRFS™ | Hero

Reliable™ R1026 Model G Upright Sprinkler | SR | 8.0K | Chrome | 135F | GU0LHC | QRFS™ | Hero
Reliable™ R1026 Model G Upright Sprinkler | SR | 8.0K | Chrome | 135F | GU0LHC | QRFS™ | Front
Reliable™ R1026 Model G Upright Sprinkler | SR | 8.0K | Chrome | 165F | GU1LHC | QRFS™ | Deflector
Overview

Reliable™ Model G Standard Response Upright (R1026) Fire Sprinkler Head

Sprinkler Identification Number (SIN): R1026

This Upright sprinkler features a Chrome finish and 135F (57C) temperature.

This Reliable™ Model G Upright Fire Sprinkler is a standard coverage Upright fire sprinkler head, activating at 135F (57C) with a 8.0 K-Factor, and is rated for All Hazard occupancies (Light, Ordinary, Extra). Each Upright head features a heat-sensitive fusible link assembly, standard 1/2 in. NPT threads, and a brass frame with a brass deflector.

This is a standard response, standard coverage, Upright sprinkler with a maximum working water pressure of 175 PSI (12 BAR). The R1026 Model G Sprinkler features a low profile and compact design. Using a heat-activated fusible link assembly, this automatic fire sprinkler opens when ambient temperatures reach the sprinkler’s listed activation temperature, drenching the area surrounding a fire to keep it in its place of origin.

Reliable™ Model G Fire Sprinkler R1026 Sprinkler Head Listings and Approvals

Each G sprinkler is made by Reliable™, a global leader in fire protection manufacturing. When installed properly, this R1026 fire sprinkler head maintains listings and approvals:

UL, FM

Refer to the datasheet for listings and approvals in specific temperatures and/or applications.

When using Reliable™ Upright Sprinkler R1026 for systems designed to NFPA standards, apply the listed areas of coverage and minimum water supply requirements shown in the manufacturer datasheet. This Upright sprinkler head has a maximum working pressure of 175 PSI (12 BAR) and connects to wet piping systems.

Reliable™ (R1026) G Upright Sprinkler Installation and Other Information

The R1026 Upright Sprinkler is installed exposed in the Upright orientation. Refer to the manufacturer data sheet for installation instructions with the approved Reliable™ accessories. During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional installation and storage information.

Model G Series standard spray upright and pendent sprinklers having K-factors of 5.6 (80) and higher are permitted to be used in all occupancy classifications and building construction types unless otherwise noted. Model G Series standard spray upright and pendent sprinklers having K-factors less than 5.6 (80) are limited to light hazard occupancies.

Available finish options include Brass and Chrome.
Only frame and deflector are coated, operating parts are chrome plated.

Temperature options include 135F (57C), 165F (74C), 212F (100C), and 286F (141C). Finish and temperature combinations available in the “Options” section at the top of this product page.

The R1026 listed wrenches include the approved Reliable™ Model W2. Add the correct wrench for your R1026 installation.

Other listed accessories include Reliable™ sprinkler head guards and water shields, listed below and available at the top of this page. Prevent accidental activation or damage to your R1026 sprinkler by installing the appropriate head guard and ensure the timely activation of your intermediate Upright sprinkler head by installing an appropriate water shield. Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page.

Available Reliable™ R1026 Upright Sprinklers & Listed Accessories:

Brass Finish
Reliable™ R1026 Model G Upright Sprinkler | SR | 8.0K | Brass | 135F | GU0LHB
Reliable™ R1026 Model G Upright Sprinkler | SR | 8.0K | Brass | 165F | GU1LHB
Reliable™ R1026 Model G Upright Sprinkler | SR | 8.0K | Brass | 212F | GU2LHB
Reliable™ R1026 Model G Upright Sprinkler | SR | 8.0K | Brass | 286F | GU3LHB

Chrome Finish
Reliable™ R1026 Model G Upright Sprinkler | SR | 8.0K | Chrome | 135F | GU0LHC
Reliable™ R1026 Model G Upright Sprinkler | SR | 8.0K | Chrome | 165F | GU1LHC
Reliable™ R1026 Model G Upright Sprinkler | SR | 8.0K | Chrome | 212F | GU2LHC
Reliable™ R1026 Model G Upright Sprinkler | SR | 8.0K | Chrome | 286F | GU3LHC

Wrenches:
W-2 Fire Sprinkler Wrench | WW2 | Upright

Guards & Shields:
D-1 Guard (UL)
C-1 Guard (FM)
C-3 Guard with Shield (UL, FM on R1026, R1026, and R1027 only)

Reviews
No reviews yet
Product Alternatives