Reliable™ R1344 Extended Coverage Institutional Pendent Sprinkler | QR | 5.6K | Chrome | 165F | XLEPC

SKU:
R1344CH165
Manufacturer Part Number:
XLEPC
$122.60

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
R1344CH165
Manufacturer Part Number:
XLEPC
Manufacturer:
Reliable™
SIN:
R1344
Model:
Model XL
Head Type:
Extended Coverage Institutional Pendent
Finish:
Chrome
Finish Detail:
Chrome
Size:
1/2 in.
Size Detail:
1/2 in. NPT Sprinkler
K Factor:
5.6K
Response Type:
Quick Response (QR)
Temperature:
165F
Heat Element:
Fusible Link
Coverage:
Extended Coverage
Material:
CDA Alloy Frame, Brass Deflector
Corrosion Resistant:
No
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
No
Occupancy Type:
Light Hazard
Maximum Working Water Pressure:
175 PSI
Escutcheon Type:
Recessed or Surface Mounted
Sourced Location:
USA
Length:
in. (0 mm)
Width:
in. (0 mm)
Height:
in. (0 mm)
Weight:
lbs. (0 kg)
System Type:
Wet

Reliable™ R1344 Extended Coverage Institutional Pendent Sprinkler | QR | 5.6K | Chrome | 165F | XLEPC | QRFS™ | Hero

Reliable™ R1344 Extended Coverage Institutional Pendent Sprinkler | QR | 5.6K | Chrome | 165F | XLEPC | QRFS™ | Hero
Reliable™ R1344 Extended Coverage Institutional Pendent Sprinkler | QR | 5.6K | Chrome | 165F | XLEPC | QRFS™ | Assembled
Reliable™ R1344 Extended Coverage Institutional Pendent Sprinkler | QR | 5.6K | Chrome | 165F | XLEPC | QRFS™ | Side
Reliable™ R1344 Extended Coverage Institutional Pendent Sprinkler | QR | 5.6K | Chrome | 165F | XLEPC | QRFS™ | Deflector
Overview

Reliable™ Model XL EC Institutional Pendent QR Fire Sprinkler Head

Sprinkler Identification Number (SIN): R1344

This Extended Coverage  Institutional Pendent sprinkler features a Chrome finish and a 165°F (73°C) activation temperature.

This Reliable™ Model XL Flush EC Institutional Pendent Fire Sprinkler is a quick response, extended coverage sprinkler, activating at 165°F with a 5.6K K-Factor, and is rated for light hazard occupancies. Each Pendent head features a heat-sensitive fusible link assembly, extended 1/2 in. NPT threads, and a CDA Alloy frame with Brass deflector.

This is a quick response, extended coverage, EC Institutional sprinkler with a maximum working water pressure of 175 PSI. The Reliable™ EC Institutional Sprinkler features a tamper-resistant design, making it a safe and effective choice for use with concealed piping in various EC Institutional mental health occupancies, correctional facilities, or other settings where flush, tamper-resistant sprinklers may be required.

Using a heat-activated fusible link assembly, this automatic fire sprinkler opens when ambient temperatures reach 165°F, effectively containing the spread of fire. The R1344 is installed flush using the corresponding flush escutcheon, leaving exposed only a small portion of the fusible link assembly to ensure the timely activation of the fire sprinkler. Refer to the manufacturer data sheet for installation instructions with the approved Reliable™ escutcheon(s).

Reliable™ Flush EC Institutional Fire Sprinkler (R1344) Sprinkler Head Listings and Approvals

Each EC Institutional sprinkler is made by Reliable™, a global leader in fire protection manufacturing for nearly 100 years. When installed properly, this R1344 maintains the following listings and approvals:

cULus (Light Hazard)

Refer to the datasheet for listings and approvals in specific temperatures and/or applications.

The Reliable™ EC Institutional Pendent Sprinkler R1344 is designed for NFPA 25. Apply the listed areas of coverage and minimum water supply requirements as shown in the datasheet. This Pendent sprinkler head has a maximum working pressure of 175 PSI (12.1 BAR) and connects to wet fire protection systems.

Reliable™ R1344 EC Institutional Fire Sprinkler Head Listings and Approvals

During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional installation and storage information.

The listed R1344 accessories include the approved Reliable™ ZX-Pendent Wrench (PN. WZXP) and the approved Reliable™ Escutcheon(s). Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page.