Reliable™ R1425 Upright Sprinkler | SR | 5.6K | Brass | 212F | 516A114299

SKU:
R1425BR212
Manufacturer Part Number:
516A114299
$86.16
Data Sheet Product Data Sheet

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
R1425BR212
Manufacturer Part Number:
516A114299
Manufacturer:
Reliable™
SIN:
R1425
Model:
G Upright Intermediate
Head Type:
Upright
Finish:
Brass
Finish Detail:
Bronze
Size:
1/2 in.
Size Detail:
1/2 in. NPT Sprinkler
K Factor:
5.6K
Response Type:
Standard Response (SR)
Temperature:
212F
Heat Element:
Fusible Link
Coverage:
Standard Coverage
Material:
Brass Frame, Brass Deflector
Corrosion Resistant:
No
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
Yes
Maximum Working Water Pressure:
175 PSI
Sourced Location:
USA
Length:
3 in. (76.2 mm)
Width:
3.25 in. (82.55 mm)
Height:
3 in. (76.2 mm)
Weight:
0.59 lbs. (0.27 kg)
System Type:
Wet

Reliable™ R1425 Upright Sprinkler | SR | 5.6K | Brass | 212F | 516A114299

Reliable™ R1425 Upright Sprinkler | SR | 5.6K | Brass | 212F | 516A114299
Reliable™ R1425 Upright Sprinkler | SR | 5.6K | Brass | 212F | 516A114299
Reliable™ R1425 Upright Sprinkler | SR | 5.6K | Brass | 212F | 516A114299
Reliable™ R1425 Upright Sprinkler | SR | 5.6K | Brass | 212F | 516A114299
Overview

Reliable™ 516A114299 Product Description

Reliable™ Model G Upright Intermediate Fire Sprinkler Head
Sprinkler Identification Number (SIN): R1425

This Upright sprinkler features a Brass finish and a 212°F (100°C) temperature.

This Reliable™ Model G Upright Intermediate Fire Sprinkler is a standard response, standard coverage sprinkler, activating at 212°F with a 5.6 K-Factor. Each upright head features a fusible link heat element, Standard 1/2 in. NPT threads, and a brass frame with brass deflector.

This is a standard response, standard coverage, upright sprinkler with a maximum working water pressure of 175 PSI. Using a fusible link, this automatic fire sprinkler opens when ambient temperatures reach 212°F.

The R1425 is installed in the upright position. Refer to the manufacturer data sheet for installation instructions and orientation-specific limitations.


Reliable™ Upright Fire Sprinkler (R1425) Sprinkler Head Listings and Approvals

Each sprinkler head is made by Reliable™, a manufacturer with a long-standing history of fire protection solutions. When installed properly, this R1425 maintains the following listings and approvals: UL Listed and FM Approved.

The Reliable™ Upright Sprinkler R1425 is designed for NFPA 13. Apply the listed areas of coverage and minimum water supply requirements as shown in the datasheet. This Upright sprinkler head has a maximum working pressure of 175 PSI (12.1 BAR) and connects to wet pipe fire protection systems.


Reliable™ R1425 Automatic Fire Sprinkler Installation and Accessories

During installation, be aware that over-tightening may cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinkler itself. Use the manufacturer-approved installation wrench and tighten according to the specifications provided in the data sheet.

Listed R1425 Accessories include:
Guards and Shields:

  • Factory Water Shield (cULus, FM)

Sprinkler Wrench:

  • Model W2


Available Sprinklers in R1425 Family

  • Brass, 135°F

  • Brass, 165°F

  • Brass, 212°F

  • Brass, 286°F

Reviews
No reviews yet
Product Alternatives