Reliable™ RA1425 Upright Sprinkler | QR | 5.6K | Brass | 155F | F1FR56U1BN

SKU:
RA1425BR155
Manufacturer Part Number:
F1FR56U1BN
$19.50
Data Sheet Product Data Sheet

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
RA1425BR155
Manufacturer Part Number:
F1FR56U1BN
Manufacturer:
Reliable™
SIN:
RA1425
Model:
F1FR56
Head Type:
Upright
Finish:
Brass
Finish Detail:
Brass
Size:
1/2 in.
Size Detail:
1/2 in. NPT Sprinkler
K Factor:
5.6K
Response Type:
Quick Response (QR)
Temperature:
155F
Heat Element:
Glass Bulb
Coverage:
Standard Coverage
Material:
Brass Frame, Brass Deflector
Corrosion Resistant:
No
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
Yes
Occupancy Type:
Light/Ordinary Hazard
Maximum Working Water Pressure:
250 PSI
Sourced Location:
USA
Length:
1.26 in. (32.004 mm)
Width:
1.26 in. (32.004 mm)
Height:
2.3 in. (58.42 mm)
Weight:
0.16 lbs. (0.07 kg)
System Type:
Wet

Reliable™ RA1425 Upright Sprinkler | QR | 5.6K | Brass | 155F | F1FR56U1BN

Reliable™ RA1425 Upright Sprinkler | QR | 5.6K | Brass | 155F | F1FR56U1BN
Reliable™ RA1425 Upright Sprinkler | QR | 5.6K | Brass | 155F | F1FR56U1BN
Reliable™ RA1425 Upright Sprinkler | QR | 5.6K | Brass | 155F | F1FR56U1BN
Reliable™ RA1425 Upright Sprinkler | QR | 5.6K | Brass | 155F | F1FR56U1BN
Overview

Reliable™ Model F1FR56 Quick Response Upright (RA1425) Fire Sprinkler Head

Sprinkler Identification Number (SIN): RA1425

This Upright sprinkler features a Brass finish and 155F (68C) temperature.

This Reliable™ Model F1FR56 Upright Fire Sprinkler is a standard coverage Upright fire sprinkler head, activating at 155F (68C) with a 5.6 K-Factor, and is rated for Light and Ordinary Hazard occupancies. Each Upright head features a heat-sensitive glass bulb assembly, standard 1/2 in. NPT threads, and a brass frame with a brass/bronze deflector.

This is a quick response, standard coverage, Upright sprinkler with a maximum working water pressure of 250 PSI (17 BAR) (cULus only). The RA1425 Model F1FR56 Sprinkler features a low profile and compact design. Using a heat-activated glass bulb assembly, this automatic fire sprinkler opens when ambient temperatures reach the sprinkler’s listed activation temperature, drenching the area surrounding a fire to keep it in its place of origin.

Reliable™ Model F1FR56 Fire Sprinkler RA1425 Sprinkler Head Listings and Approvals

Each F1FR56 sprinkler is made by Reliable™, a global leader in fire protection manufacturing for over 100 years. When installed properly, this RA1425 fire sprinkler head maintains listings and approvals:

cULus Listed
FM Approved
LPCB
VdS
EC
WM
UKCA: 0832-UKCA-CPR-S5045

Refer to the datasheet for listings and approvals in specific temperatures and/or applications.

When using Reliable™ Upright Sprinkler RA1425 for systems designed to NFPA 13, apply the listed areas of coverage and minimum water supply requirements shown in the manufacturer datasheet. This Upright sprinkler head has a maximum working pressure of 250 PSI (17 BAR) and connects to wet piping systems.

Reliable™ F1FR56 (RA1425) Upright Sprinkler Installation and Other Information

The RA1425 Upright Sprinkler is installed exposed in the Upright orientation. Refer to the manufacturer data sheet for installation instructions with the approved Reliable™ accessories. During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional installation and storage information.

Available finish options include Brass, Chrome, and White.
White Polyester Finish (White) is UL Listed as corrosion resistant.

Temperature options include 135F (57C), 155F (68C), 175F (79C), 200F (93C), and 286F (141C). Finish and temperature combinations available in the “Options” section at the top of this product page.

The RA1425 listed wrenches include the approved Reliable™ Model W2, Model W14 (New frame with guard installed), and Model W13 (Legacy frame with guard installed). Add the correct wrench for your RA1425 installation. Sprinklers with Legacy frames require an alternative W13 wrench for proper installation.

Other listed accessories include Reliable™ sprinkler head guards and water shields, listed below and available at the top of this page. Prevent accidental activation or damage to your RA1425 sprinkler by installing the appropriate head guard and ensure the timely activation of your intermediate Upright sprinkler head by installing an appropriate water shield. Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page.

Available Reliable™ RA1425 Upright Sprinklers & Listed Accessories:

Brass Finish
Reliable™ RA1425 Upright Sprinkler | QR | 5.6K | Brass | 155F | F1FR56U1BN
Reliable™ RA1425 Upright Sprinkler | QR | 5.6K | Brass | 135F | F1FR56U0BN
Reliable™ RA1425 Upright Sprinkler | QR | 5.6K | Brass | 175F | F1FR56U5BN
Reliable™ RA1425 Upright Sprinkler | QR | 5.6K | Brass | 200F | F1FR56U2BN
Reliable™ RA1425 Upright Sprinkler | QR | 5.6K | Brass | 286F | F1FR56U3BN

Chrome Finish
Reliable™ RA1425 Upright Sprinkler | QR | 5.6K | Chrome | 135F | F1FR56U0CN
Reliable™ RA1425 Upright Sprinkler | QR | 5.6K | Chrome | 155F | F1FR56U1CN
Reliable™ RA1425 Upright Sprinkler | QR | 5.6K | Chrome | 175F | F1FR56U5CN
Reliable™ RA1425 Upright Sprinkler | QR | 5.6K | Chrome | 200F | F1FR56U2CN
Reliable™ RA1425 Upright Sprinkler | QR | 5.6K | Chrome | 286F | F1FR56U3CN

White Finish
Reliable™ RA1425 Upright Sprinkler | QR | 5.6K | White | 135F | F1FR56U0WN
Reliable™ RA1425 Upright Sprinkler | QR | 5.6K | White | 155F | F1FR56U1WN
Reliable™ RA1425 Upright Sprinkler | QR | 5.6K | White | 175F | F1FR56U5WN
Reliable™ RA1425 Upright Sprinkler | QR | 5.6K | White | 200F | F1FR56U2WN
Reliable™ RA1425 Upright Sprinkler | QR | 5.6K | White | 286F | F1FR56U3WN

Wrenches:

W-2 Fire Sprinkler Wrench | WW2 | Upright
W-14 Fire Sprinkler Wrench | W14 | New frame with guard installed
W-13 Fire Sprinkler Wrench | W13 | Legacy frame with guard installed

Guards & Shields (New Frames):

Factory Water Shield (cULus, FM) F-1 Guard (cULus, FM)
F-3 Guard with Shield (cULus, FM)

Guards & Shields (Legacy Frames):
Factory Water Shield
C-1 Guard (FM)
C-3 Guard with Shield (cULus, FM)
D-1 Guard (cULus)
D-3 Guard with Shield (cULus)

Reviews
No reviews yet
Product Alternatives