Reliable™ RA2625 Upright Sprinkler | QR | 5.6K | Chrome | 135F | BF132132S9

SKU:
RA2625CH135
Manufacturer Part Number:
BF132132S9
$21.84
Data Sheet Product Data Sheet

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
RA2625CH135
Manufacturer Part Number:
BF132132S9
Manufacturer:
Reliable™
SIN:
RA2625
Model:
F1FR56-300
Head Type:
Upright
Finish:
Chrome
Finish Detail:
Chrome
Size:
1/2 in.
Size Detail:
1/2 in. NPT Sprinkler
K Factor:
5.6K
Response Type:
Quick Response (QR)
Temperature:
135F
Heat Element:
Glass Bulb
Coverage:
Standard Coverage
Material:
Brass Frame, Brass Deflector
Corrosion Resistant:
No
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
No
Other Listings:
cULus Listed
Maximum Working Water Pressure:
300 PSI
Sourced Location:
USA
Length:
2.25 in. (57.15 mm)
Width:
1 in. (25.4 mm)
Height:
2.25 in. (57.15 mm)
Weight:
0.14 lbs (0.06 kg)
System Type:
Wet

Reliable™ RA2625 Upright Sprinkler | QR | 5.6K | Chrome | 135F | BF132132S9

Reliable™ RA2625 Upright Sprinkler | QR | 5.6K | Chrome | 135F | BF132132S9
Reliable™ RA2625 Upright Sprinkler | QR | 5.6K | Chrome | 135F | BF132132S9
Reliable™ RA2625 Upright Sprinkler | QR | 5.6K | Chrome | 135F | BF132132S9
Reliable™ RA2625 Upright Sprinkler | QR | 5.6K | Chrome | 135F | BF132132S9
Overview

Reliable™ RA2625CH135 Product Description

Reliable™ Model F1FR56-300 Upright Fire Sprinkler Head

Sprinkler Identification Number (SIN): RA2625

This Upright sprinkler features a Chrome finish and a 135°F (57°C) temperature.

This Reliable™ Model RA2625 Upright Fire Sprinkler is a quick response, standard coverage sprinkler, activating at 135°F with a 5.6 K-Factor. Each upright head features a heat-sensitive glass bulb, standard 1/2 in. NPT threads, and a brass frame with brass deflector.

This is a quick response, standard coverage, upright sprinkler with a maximum working water pressure of 300 PSI. Using a heat-activated glass bulb, this automatic fire sprinkler opens when ambient temperatures reach 135°F, effectively containing the spread of fire.

The RA2625 is installed in the upright position in accordance with manufacturer instructions and NFPA 13 guidelines. Refer to the manufacturer data sheet for installation instructions with approved accessories.

Reliable™ Upright Fire Sprinkler (RA2625) Sprinkler Head Listings and Approvals

Each sprinkler head is made by Reliable™, a long-standing manufacturer of fire protection equipment. When installed properly, this RA2625 maintains the following listings and approvals: UL, cULus
Note: Listings and approvals may vary depending on installation method and orientation. Always refer to the datasheet for installation-specific approvals.

The Reliable™ Upright Sprinkler RA2625 is designed for NFPA 13 fire protection systems. Apply the listed areas of coverage and minimum water supply requirements as shown in the datasheet. This Upright sprinkler head has a maximum working pressure of 300 PSI (20.7 BAR) and connects to wet pipe fire protection systems.

Reliable™ RA2625 Automatic Fire Sprinkler Installation and Accessories

During installation, be aware that over-tightening may cause permanent damage to the 1/2 in. NPT threads or the sprinkler itself. Use the manufacturer-approved installation wrench. Refer to the datasheet for additional installation and handling guidelines.

Listed RA2625 Accessories include:

Guards & Shields (New Frames):
F-1 Guard
F-3 Guard with Shield

Guards & Shields (Legacy Frames):
C-3 Guard with Shield
D-1 Guard
D-3 Guard with Shield

Sprinkler Wrenches:
Model W2
Model W14 (new frame with guard installed)
Model W13 (legacy frame with guard installed)

Available Sprinklers

This upright sprinkler head is also available in Brass and White Polyester finishes and in 155°F, 175°F, 200°F, and 286°F temperature options.