Reliable™ RA2625 Upright Sprinkler | QR | 5.6K | White | 155F | BF158732S9

SKU:
RA2625WH155
Manufacturer Part Number:
BF158732S9
$22.19
Data Sheet Product Data Sheet

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
RA2625WH155
Manufacturer Part Number:
BF158732S9
Manufacturer:
Reliable™
SIN:
RA2625
Model:
F1FR56-300
Head Type:
Upright
Finish:
White
Finish Detail:
White Polyester
Size:
1/2 in.
Size Detail:
1/2 in. NPT Sprinkler
K Factor:
5.6K
Response Type:
Quick Response (QR)
Temperature:
155F
Heat Element:
Glass Bulb
Coverage:
Standard Coverage
Material:
Brass Frame, Brass Deflector
Corrosion Resistant:
Yes
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
No
Other Listings:
cULus Listed
Maximum Working Water Pressure:
300 PSI
Sourced Location:
USA
Length:
2.25 in. (57.15 mm)
Width:
1 in. (25.4 mm)
Height:
2.25 in. (57.15 mm)
Weight:
0.14 lbs (0.06 kg)
System Type:
Wet

Reliable™ RA2625 Upright Sprinkler | QR | 5.6K | White | 155F | BF158732S9

Reliable™ RA2625 Upright Sprinkler | QR | 5.6K | White | 155F | BF158732S9
Reliable™ RA2625 Upright Sprinkler | QR | 5.6K | White | 155F | BF158732S9
Reliable™ RA2625 Upright Sprinkler | QR | 5.6K | White | 155F | BF158732S9
Reliable™ RA2625 Upright Sprinkler | QR | 5.6K | White | 155F | BF158732S9
Overview

Reliable™ RA2625WH155 Product Description
Reliable™ Model F1FR56-300 Upright Fire Sprinkler Head

Sprinkler Identification Number (SIN): RA2625

This Upright sprinkler features a White finish and a 155°F (68°C) temperature.

This Reliable™ Model RA2625 Upright Fire Sprinkler is a quick response, standard coverage sprinkler, activating at 155°F with a 5.6 K-Factor. Each upright head features a heat-sensitive glass bulb, standard 1/2 in. NPT threads, and a brass frame with a polyester-coated white finish on the deflector.

This is a quick response, standard coverage, upright sprinkler with a maximum working water pressure of 300 PSI. Using a heat-activated glass bulb, this automatic fire sprinkler opens when ambient temperatures reach 155°F, effectively containing the spread of fire.

The RA2625 is installed in the upright position in accordance with manufacturer instructions and NFPA 13 guidelines. Refer to the manufacturer data sheet for installation instructions with approved accessories.

Reliable™ Upright Fire Sprinkler (RA2625) Sprinkler Head Listings and Approvals

Each sprinkler head is made by Reliable™, a trusted name in fire protection. When installed properly, this RA2625 maintains the following listings and approvals: UL, cULus
Note: Listings and approvals may vary depending on installation configuration. Always refer to the datasheet for installation-specific guidance.

The Reliable™ Upright Sprinkler RA2625 is designed for NFPA 13 fire protection systems. Apply the listed areas of coverage and minimum water supply requirements as shown in the datasheet. This Upright sprinkler head has a maximum working pressure of 300 PSI (20.7 BAR) and connects to wet pipe fire protection systems.

Reliable™ RA2625 Automatic Fire Sprinkler Installation and Accessories

Avoid over-tightening during installation, as it can damage the 1/2 in. NPT threads or sprinkler body. Use the manufacturer-approved installation wrench. Refer to the data sheet for additional handling and storage information.

Listed RA2625 Accessories include:

Guards & Shields (New Frames):

  • F-1 Guard

  • F-3 Guard with Shield

Guards & Shields (Legacy Frames):

  • C-3 Guard with Shield

  • D-1 Guard

  • D-3 Guard with Shield

Sprinkler Wrenches:

  • Model W2

  • Model W14 (new frame with guard installed)

  • Model W13 (legacy frame with guard installed)

Available Sprinklers

This upright sprinkler head is also available in Brass and Chrome finishes and in 135°F, 175°F, 200°F, and 286°F temperature options.

Reviews
No reviews yet
Product Alternatives