Reliable™ RA6424 Upright Sprinkler | SR | 5.6K | Stainless Steel | 155F | AA151032R9

SKU:
RA6424SS155
Manufacturer Part Number:
AA151032R9
$424.58

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
RA6424SS155
Manufacturer Part Number:
AA151032R9
Manufacturer:
Reliable™
SIN:
RA6424
Model:
F1-56SS Upright
Head Type:
Upright
Finish:
Stainless Steel
Finish Detail:
Stainless Steel
Size:
1/2 in.
Size Detail:
1/2 in. NPT Sprinkler
K Factor:
5.6K
Response Type:
Standard Response (SR)
Temperature:
155F
Heat Element:
Glass Bulb
Coverage:
Standard Coverage
Material:
Stainless Steel Frame, Stainless Steel Deflector
Corrosion Resistant:
Yes
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
Yes
Other Listings:
cULus Listed, CE, VdS
Maximum Working Water Pressure:
175 PSI
Sourced Location:
USA
Length:
2.375 in. (60 mm)
Width:
1.375 in. (33 mm)
Height:
2.375 in. (60 mm)
Weight:
lbs. (0 kg)
System Type:
Wet

Reliable™ RA6424 Upright Sprinkler | SR | 5.6K | Chrome | 155F | AA151032R9 | Hero

Reliable™ RA6424 Upright Sprinkler | SR | 5.6K | Chrome | 155F | AA151032R9 | Hero
Reliable™ RA6424 Upright Sprinkler | SR | 5.6K | Chrome | 155F | AA151032R9 | Side
Reliable™ RA6424 Upright Sprinkler | SR | 5.6K | Chrome | 155F | AA151032R9 | Alt Side
Reliable™ RA6424 Upright Sprinkler | SR | 5.6K | Chrome | 155F | AA151032R9 | Deflector
Overview

Reliable™ RA6424SS155 Product Description

Reliable™ Model F1-56SS Upright Fire Sprinkler Head

Sprinkler Identification Number (SIN): RA6424

This Upright sprinkler features a Stainless Steel finish and a 155°F (68°C) temperature rating.

The Reliable™ Model F1-56SS Upright Fire Sprinkler is a standard response, standard coverage sprinkler head with a 5.6 K-Factor. It includes a heat-sensitive 3 mm glass bulb and a 1/2 in. NPT connection. The frame and deflector are made from stainless steel for added corrosion resistance, and the finish is Stainless Steel.

This is a standard response, standard coverage upright sprinkler with a maximum working pressure of 175 PSI. The unit operates using a heat-activated glass bulb, which opens at 155°F to initiate sprinkler operation.

RA6424 sprinklers are installed in the upright position only. Refer to the manufacturer data sheet for installation specifications and approved accessories.


Reliable™ Upright Fire Sprinkler (RA6424) Listings and Approvals

Each sprinkler head is manufactured by Reliable™, a recognized fire protection equipment manufacturer. When properly installed, this RA6424 variant maintains the following approvals:

  • UL Listed

  • cULus Listed

  • FM Approved

  • CE Marked

  • VdS Approved


RA6424 Upright Sprinkler – Design Parameters

The Reliable™ RA6424SS155 is intended for use in NFPA 13-compliant systems. Apply the listed areas of coverage and minimum water supply requirements as described in the data sheet. This upright sprinkler connects to wet-pipe fire protection systems and has a maximum working pressure of 175 PSI (12.1 BAR).


RA6424 Installation and Approved Accessories

Installers must avoid over-tightening, which can damage the 1/2 in. NPT thread or the sprinkler head. Use the manufacturer-approved installation wrench and tighten to the specified torque noted in the data sheet. Always reference the technical bulletin for proper installation and storage guidelines.

Approved Accessories:

Sprinkler Wrench:

  • Model W2 Installation Wrench

Guards & Shields:

  • D-1 Guard (cULus)

  • D-3 Guard & Shield (cULus)

  • C-1 Guard (FM – available in type 316 stainless steel)

  • C-3 Guard & Shield (cULus, FM)

Note: Guards and shields for this model are not corrosion resistant unless otherwise specified.


Available RA6424 Sprinkler Heads

This upright sprinkler is also available in a Stainless Steel finish at the following temperature ratings:

  • 135°F (57°C)

  • 155°F (68°C)

  • 175°F (79°C)

  • 200°F (93°C)

  • 286°F (141°C)

  • 360°F (182°C)

  • 500°F (260°C)