Retrofit Two Piece Escutcheon | Recessed | Chrome | 3/4 in. Sprinkler

SKU:
12-LN-RCSTRF-CP75
Manufacturer Part Number:
100-225-02680
$5.22
Data Sheet Product Data Sheet

Select Variation

  • Buy 50 - 249 and get 2.5% off
  • Buy 250 or above and get 7.5% off

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
12-LN-RCSTRF-CP75
Manufacturer:
Lansdale™
Model:
Recessed
Material:
Steel
Installation Type:
Push On
Adjustment:
3/4 in.
Outer Diameter:
2-23/25 in.
Inner Diameter:
1-22/25 in.
Sprinkler Size:
3/4 in. Sprinkler
Finish:
Chrome
Finish Detail:
Chrome
Corrosion Resistant:
No
UL Listed:
No
FM Approved:
No
Length:
3.92 in. (99.57 mm)
Width:
3.92 in. (99.57 mm)
Height:
1.1 in. (27.94 mm)
Weight:
0.1 lb. (0.05 kg)

Retrofit Two Piece Escutcheon | Recessed | Chrome | 3/4 in. Sprinkler | Hero

Retrofit
Best Seller
Retrofit Two Piece Escutcheon | Recessed | Chrome | 3/4 in. Sprinkler | Hero
Retrofit Two Piece Escutcheon | Recessed | Chrome | 3/4 in. Sprinkler | Front
Retrofit Two Piece Escutcheon | Recessed | Chrome | 3/4 in. Sprinkler | Inner Ring
Retrofit Two Piece Escutcheon | Recessed | Chrome | 3/4 in. Sprinkler | Side
Play Button
Overview

Two Piece Recessed Retrofit Escutcheon for 1/2 in. NPT Sprinklers in Chrome

These devices cover the holes surrounding fire sprinkler heads that were cut during installation, making sprinklers look cleaner and ensuring they work correctly. This Chrome two-piece retrofit (split ring) escutcheon is sized for 3/4 in. NPT fire sprinklers and allow for up to 3/4 in. adjustment to cover open space between the fire sprinkler head and the ceiling.

This two-piece Steel escutcheon has an outer diameter of 2-23/25 in. It features an aesthetically pleasing chrome finish and replaces corroded, painted, damaged, or unsightly escutcheons. To install this retrofit fire sprinkler escutcheon, cut one side of the faulty escutcheon, remove it, and fasten the two halves of the retrofitted escutcheon ring to the fire sprinkler's frame.

Note: This product is not listed by cULus, approved by FM, or other approval/listings organizations. If you need a replacement escutcheon, and you know your fire sprinkler’s Sprinkler Identification Number (SIN), use our tool to find the listed and/or approved escutcheon.

NFPA 13 stipulates that a recessed sprinkler “shall be installed with the escutcheon that is part of its listing.” Non-listed recessed escutcheons should only be used if the appropriate authority having jurisdiction approves their use.