Senju™ CN Cover Plate | Ivory | 140F | 2-3/8 in. OD | 004-0351

SKU:
11-SS-00403-IV140
Manufacturer Part Number:
004-0351
$21.25
Data Sheet Product Data Sheet

Select Variation

Want It Customized?
Please Note: Cover plates are designed for specific sprinkler heads. Size alone does not guarantee compatibility. To ensure the correct fit, please use our Sprinkler Cover Plate Finder Tool.

  • Buy 100 - 199 and get 2.5% off
  • Buy 200 or above and get 7.5% off

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
11-SS-00403-IV140
Manufacturer Part Number:
004-0351
Manufacturer:
Senju™
Model:
CN
Installation Type:
Push On
Adjustment:
1/2 in.
Outer Diameter:
2-3/8 in.
Inner Diameter:
1-3/8 in.
Finish:
White
Finish Detail:
Ivory
Temperature:
140F
Corrosion Resistant:
No
UL Listed:
Yes
FM Approved:
Yes
Length:
2.38 in. (60.45 mm)
Width:
2.38 in. (60.45 mm)
Height:
1.02 in. (25.91 mm)
Weight:
0.17 lb. (0.08 kg)

Senju™ CN Cover Plate | Ivory | 140F | 2-3/8 in. OD | 004-0351

Senju™ CN Cover Plate | Ivory | 140F | 2-3/8 in. OD | 004-0351
Senju™ CN Cover Plate | Ivory | 140F | 2-3/8 in. OD | 004-0351
Senju™ CN Cover Plate | Ivory | 140F | 2-3/8 in. OD | 004-0351
Senju™ CN Cover Plate | Ivory | 140F | 2-3/8 in. OD | 004-0351
Senju™ CN Cover Plate | Ivory | 140F | 2-3/8 in. OD | 004-0351
Play Button
Overview

Senju™ CN Fire Sprinkler Cover Plate

Senju™ CN Ivory Fire Sprinkler Cover Plate with 140F (60C) activation temperature. This fire sprinkler cover works with Senju™’s Series CN concealed pendent fire sprinklers.  The CN cover facilitates timely activation of the CN concealed fire sprinkler heads with a temperature rating of 140F (60C) (White also available in 162F). This sprinkler cover has an outer diameter or 2-3/8 in. and an inner diameter of 1-3/8 in.

The Senju™ CN cover plate is perfect for residential or commercial building owners who are intent on matching their ceiling’s finish with their fire sprinkler cover; the CN cover is available in 11 different finishes without incurring additional fees. These finishes include White, Ivory, Beige, Brown, Black, Nickel, and 5 Wood Grain variants (Douglas Fir, Cherry Chestnut, Golden Oak, Yellow Birch, and Dark Walnut).  Along with these base finishes, for an additional fee Senju™ will custom paint this cover in any finish you prefer, so long that Senju™ can purchase the paint locally. If the paint brand cannot be bought locally, you must provide Senju™ with at least 1 quart of the paint you choose. Contact QRFS™ customer support for more details.

Senju™ CN Fire Sprinkler Cover Plate Sprinkler Head Compatibility and Listings

This Sprinkler Head Cover Plate from Senju™ is UL Listed, and/or may be listed/approved by other organizations depending on the sprinkler. It meets the requirements of a sprinkler assembly per NFPA 13, where approved by the local Authority Having Jurisdiction. It installs by simply pushing the cover into the sprinkler’s frame.

To remove your existing cover plate, gently twist the cover to the left while applying downward pressure by pulling gently as you turn.

When this Ivory fire sprinkler cover plate reaches its specified temperature of 140F (60C) or 162F (72C), the solder holding the plate's decorative exterior on the frame melts, and the two separate. For many cover plates, the rated temperature is at least 20F (6.7C) cooler than the sprinkler head's activation temperature, which ensures that the cover plate detaches early enough to allow the sprinkler to activate on time. However, each manufacturer's product line varies slightly, and cover plate temperatures may be closer to or further away from the fire sprinkler's activation temperature. Use only the cover plate approved by the manufacturer for your specific sprinkler.

Senju™ CN Cover Plate Finishes, Temperatures, and Listed Accessories

This Senju™ CN fire sprinkler cap is available in White, Ivory, Beige, Brown, Black, Nickel, and 5 Wood Grain variants (Douglas Fir, Cherry Chestnut, Golden Oak, Yellow Birch, and Dark Walnut). It is available in two temperatures: 140F (60C) or 162F (72C) (White Only). You can choose from all the available options be selecting from the dropdown at the top of the page.

This Senju™ CN Concealed sprinkler head cover is installed easily by hand. However, for tall ceilings, the Senju™ Magnetic Cover Plate Installation tool is key! Simply install the cover installation tool on a piece of 1-inch CPVC pipe and use to gently push the cover into the sprinkler’s frame. Find all related products in the Frequently Bought Together section above.

This Sprinkler Escutcheon fits the following Senju™ sprinkler heads:

  • SS9521
  • SS8421
Reviews
No reviews yet
Product Alternatives