Tyco™ LFII Cover Plate | Brushed Brass | 139F | 3-1/4 in. OD | 3/4 in. Adj. | 56-891-8-135

SKU:
11-TY-56891-BB139
Manufacturer Part Number:
56-891-8-135
$84.89
Data Sheet Product Data Sheet

Select Variation

Want It Customized?
Please Note: Cover plates are designed for specific sprinkler heads. Size alone does not guarantee compatibility. To ensure the correct fit, please use our Sprinkler Cover Plate Finder Tool.

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
11-TY-56891-BB139
Manufacturer Part Number:
56-891-8-135
Manufacturer:
Tyco™
Model:
LFII
Installation Type:
Push On
Adjustment:
3/4 in.
Outer Diameter:
3-1/4 in.
Inner Diameter:
2-1/2 in.
Finish:
Brushed Brass
Finish Detail:
Brushed Brass
Temperature:
139F
Corrosion Resistant:
No
UL Listed:
Yes
FM Approved:
No
Length:
3.25 in. (82.55 mm)
Width:
3.25 in. (82.55 mm)
Height:
1.5 in. (38.1 mm)
Weight:
0.15 lb. (0.07 kg)

Tyco™ LFII Cover Plate | Brushed Brass | 139F | 3-1/4 in. OD | 3/4 in. Adj. | 56-891-8-135 | QRFS™ | Hero

Tyco™ LFII Cover Plate | Brushed Brass | 139F | 3-1/4 in. OD | 3/4 in. Adj. | 56-891-8-135 | QRFS™ | Hero
Tyco™ LFII Cover Plate | Brushed Brass | 139F | 3-1/4 in. OD | 3/4 in. Adj. | 56-891-8-135 | QRFS™ | Side
Tyco™ LFII Cover Plate | Brushed Brass | 139F | 3-1/4 in. OD | 3/4 in. Adj. | 56-891-8-135 | QRFS™ | Label
Old LFII (1/2 in. Adjustment) vs New LFII (3/4 in. Adjustment) Cover Plate Comparison
Play Button
Overview

Tyco™ LFII Fire Sprinkler Cover Plate 3/4 in. Adjustment

Tyco™ LFII Brushed Brass Fire Sprinkler Cover Plate with 139F (59C) activation temperature. This fire sprinkler cover works with certain SINs in Tyco™’s LFII concealed pendent fire sprinkler family, including their newest residential concealed pendent LFII line.  The LFII cover facilitates timely activation of these concealed fire sprinkler heads with a temperature rating of 139F (59C) or 165F (74C). The outer diameter of this cover is 3-1/4 in. (83 mm). This cover plate features a 3/4 in. Adjustment while the older model LFII cover features a 1/2 in Adjustment. See below for compatible SINs.

The Tyco™ LFII cover plate is perfect for residential building owners who are intent on matching their ceiling’s finish with their fire sprinkler cover; the LFII cover is available in 9 different finishes without incurring additional fees. These finishes include Ivory, Bright Chrome, Beige, Signal White, Grey White, Brown, Black, Brushed Brass, and Brushed Chrome.  Along with these base finishes, for an additional fee Tyco™ will custom paint this cover in any finish you prefer, so long as the paint is from Sherwin-Williams. Contact QRFS™ customer support for more details.

Tyco™ LFII Fire Sprinkler Cover Plate Sprinkler Head Compatibility and Listings

This Sprinkler Head Cover Plate from Tyco™ is UL Listed when installed properly with a compatible sprinkler head. It meets the requirements of a sprinkler assembly per NFPA 13, where approved by the local Authority Having Jurisdiction. It installs by simply pushing the cover into the sprinkler’s frame.

To remove your existing cover plate, gently twist the cover to the left while applying downward pressure by pulling gently as you turn.

When this white fire sprinkler cover plate reaches its specified temperature of 139F (59C) or 165F (74C), the solder holding the plate's decorative exterior on the frame melts, and the two separate. For many cover plates, the rated temperature is at least 20F (6.7C) cooler than the sprinkler head's activation temperature, which ensures that the cover plate detaches early enough to allow the sprinkler to activate on time. However, each manufacturer's product line varies slightly, and cover plate temperatures may be closer to or further away from the fire sprinkler's activation temperature. Use only the cover plate approved by the manufacturer for your specific sprinkler.

Tyco™ LFII Cover Plate Finishes, Temperatures, and Listed Accessories

This Tyco™ LFII fire sprinkler cap is available in Ivory, Bright Chrome, Beige, Signal White, Grey White, Brown, Black, Brushed Brass, and Brushed Chrome. It is available in two temperatures: 139F (59C) or 165F (74C). You can choose from all the available options by selecting from the dropdown at the top of the page.

This Tyco™ sprinkler cover plate is installed easily by hand. However, for tall ceilings, the Tyco™ Cover Plate Installation tool is key! Simply install the cover installation tool on a piece of 1-inch CPVC pipe and use to gently push the cover into the sprinkler’s frame. Find all related products in the Frequently Bought Together section above.

This Sprinkler Cover Plate fits the following Tyco™ concealed sprinkler heads:

  • TY2534
  • TY3584
Reviews
No reviews yet
Product Alternatives