Tyco™ LFII (TY2334) Residential Horizontal Sidewall Sprinkler Rapid Response
This Tyco™ Series LFII Residential Brass Horizontal Sidewall Rapid Response Fire Sprinkler features a glass bulb activating at 155F (68C) with a 4.9 K-Factor, and 1/2 in. NPT threads. Each sidewall head features a brass frame and bronze deflector. The manufacturer part number is 51-215-1-155 and the Sprinkler Identification Number (SIN) is TY2334.
The LFII Residential Sidewall Sprinkler delivers effective, affordable defense against fire in residential occupancies such as homes, apartments, dormitories, and hotels. Using a heat-activated glass bulb assembly, this automatic fire sprinkler opens when ambient temperatures reach 155F (68C), drenching the area surrounding a fire to keep it in its place of origin. For recessed application, refer to data sheet for installation with the Style 20 Recessed Escutcheon.
Tyco™ LFII (TY2334) Residential Sidewall Sprinkler Head Rapid Response Listings and Approvals
Each LFII sprinkler is made by Tyco™, a global leader in fire-suppression products. This horizontal sidewall fire sprinkler head maintains UL Listing, NSF/ANSI 61 Certified, and Australian Watermark Certified.
The TY2334 is a residential sprinkler and is cULus listed for use when installed in accordance with NFPA 13 requirements for wet pipe sprinkler systems and designed for use in Residential occupancies. This horizontal sidewall sprinkler head has a maximum working pressure of 175 PSI (12.1 BAR) UL Listed and connects to wet piping systems.
Tyco™ Residential Sprinkler LFII (TY2334) Sidewall Head Rapid Response Installation and Other Information
During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional storage and installation information.
This sidewall sprinkler features a brass finish and a 155F (68C) temperature. Available finish options include Brass, White, and Chrome. Signal White Polyester (White) is UL Listed as corrosion resistant. Temperature options include 155F (68C) and 175F (79C). Finish and temperature combinations available in the “Options” section at the top of this product page.
TY2334 listed accessories include the W-Type 6 (standard) and W-Type 7 (recessed) sprinkler wrenches, manufacturer part number(s) (56-000-6-387, 56-850-4-001), the Style 20 Model Escutcheon, manufacturer part number (56-715-2-010, 56-705-2-010). Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page.