Tyco TY-B Horizontal Sidewall Fire Sprinkler | TY3351 | Standard Response | 5.6K | White | 155F | 57-578-4-155

SKU:
TY3351WH155
Manufacturer Part Number:
57-578-4-155

No reviews yet Write a Review
$25.99
Tyco Fire Sprinkler 5.6K White Horizontal Sidewall SR 155F | TY3351
Tyco Fire Sprinkler 5.6K White Horizontal Sidewall SR 155F | TY3351
Threads on Tyco Fire Sprinkler 5.6K White Horizontal Sidewall SR 155F | TY3351
Deflector on Tyco Fire Sprinkler 5.6K White Horizontal Sidewall SR 155F | TY3351
Side of Tyco Fire Sprinkler 5.6K White Horizontal Sidewall SR 155F | TY3351
Side of Tyco Fire Sprinkler 5.6K White Horizontal Sidewall SR 155F | TY3351

  • Buy 100 - 399 and get 5% off
  • Buy 400 or above and get 8% off

Frequently Bought Together:

Tyco Fire Sprinkler 5.6K White Horizontal Sidewall SR 155F | TY3351
Inc. Tax
Ex. Tax

Overview

Tyco TY3351 Standard Response White Horizontal Sidewall Fire Sprinkler delivers reliable, affordable protection against fire in ordinary-temperature applications. Using a heat-activated 5mm glass bulb, this automatic fire sprinkler opens when ambient temperatures reach 155F (68C), drenching the area surrounding a fire to keep it in its place of origin.

The Tyco Model TY3351 has a 5.6 K-Factor and installs with 1/2 in. (12.7 mm) National Pipe Thread (NPT), used in fire sprinkler systems throughout the United States. This Standard Response Fire Sprinkler features a white finish, bronze frame, bronze compression screw, bronze deflector, and a beryllium nickel sealing assembly with PTFE.

With a maximum working pressure of 175 PSI (12.1 BAR), this horizontal sidewall sprinkler installs on a wall or the side of a beam where ceiling piping is not desirable and may be installed and used in accordance with NFPA 13 and local fire code. Each Model TY3351 sprinkler is made by Tyco, a global manufacturer with more than a half-century in the fire protection industry.

This product is UL listed & FM approved for use in fire protection systems when accepted by the authority having jurisdiction. In accordance with NFPA 13, a higher temperature rating may be required when installing a standard response fire sprinkler in or near heat sources, unventilated spaces, uncovered steam mains, or uninsulated rooftops.

Specifications

Finish:
White
Response Type:
Standard Response
Temperature:
155F
Corrosion Resistance:
No
May Contain Lead:
No
Nominal K-Factor:
5.6K
Fire Sprinkler Coverage:
Standard Coverage
Fire Sprinkler Heat Element:
Glass Bulb
Fire Sprinkler Use Type:
Commercial
Fire Sprinkler Head Type:
Horizontal Sidewall
SIN Number:
TY3351
Thread Type:
NPT
Model:
TY-B
UL Listed/FM Approved:
No