Tyco™ TY313 Upright Sprinkler | QR | 5.6K | Brass | 155F | 77-370-1-155

SKU:
TY313BR155
Manufacturer Part Number:
77-370-1-155
$13.80
  • Buy 100 - 199 and get 3% off
  • Buy 200 or above and get 7% off

FAST SHIPPING: In stock items ship SAME DAY if ordered before 3PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
TY313BR155
Manufacturer Part Number:
77-370-1-155
Replaces Manufacturer Part Numbers:
57-370-1-155
Manufacturer:
Tyco™
SIN:
TY313
Model:
TY-FRB
Head Type:
Upright
Finish:
Brass
Finish Detail:
Natural Brass
Size:
1/2 in.
Size Detail:
1/2 in. NPT Sprinkler
K Factor:
5.6K
Response Type:
Quick Response (QR)
Temperature:
155F
Heat Element:
Glass Bulb
Coverage:
Standard Coverage
Material:
Bronze Frame, Bronze Deflector
Corrosion Resistant:
No
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
Yes
Maximum Working Water Pressure:
175 PSI (FM,UL) 250 PSI (UL)
Length:
1.17 in. (29.72 mm)
Width:
1.17 in. (29.72 mm)
Height:
2 in. (50.8 mm)
Weight:
0.14 lb. (0.06 kg)

Tyco™ TY313 Upright | Brass | 155F | 77-370-1-155 | Hero

Was Grinnell F980
Tyco™ TY313 Upright | Brass | 155F | 77-370-1-155 | Hero
Tyco™ TY313 Upright | Brass | 155F | 77-370-1-155 | Side
Tyco™ TY313 Upright | Brass | 155F | 77-370-1-155 | Deflector
Play Button
Overview

Tyco™ TY-FRB (TY313) Upright Quick Response Fire Sprinkler Head

This Tyco™ TY-FRB Brass Upright Quick Response Fire Sprinkler features a glass bulb activating at 155F (68C) with a 5.6 K-Factor, and 1/2 in. NPT threads. Each upright head features a bronze frame and bronze deflector. The manufacturer part number is 77-370-1-155 and the Sprinkler Identification Number (SIN) is TY313.

The TY-FRB Upright Sprinkler is designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, and shopping malls. Using a heat-activated glass bulb assembly, this automatic fire sprinkler opens when ambient temperatures reach 155F (68C), drenching the area surrounding a fire to keep it in its place of origin.

Tyco™ TY-FRB (TY313) Upright QR Fire Suppression Sprinkler Head Listings and Approvals

Each TY-FRB sprinkler is made by Tyco™, a global leader in fire-suppression products. This upright fire sprinkler head maintains UL and C-UL Listing, FM Approval, MEA 354-01-E (NYC), VdS Approval, LPCB Ref. No. 094a/06.

The TY313 is a commercial sprinkler and is cULus listed for use when installed in accordance with NFPA 13 requirements for wet pipe sprinkler systems and designed for use in commercial occupancies. This upright sprinkler head has a maximum working pressure of 175 PSI (12.1 BAR) FM, and is UL Listed for 250 PSI (17.2 bar) and connects to wet piping systems.

Tyco™ TY-FRB (TY313) Upright Quick Response Sprinkler Head Installation and Other Information

During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional storage and installation information.

This upright sprinkler features a brass finish and a 155F (68C) temperature. Finishes options include Brass, White, Black, and Chrome. Signal White Polyester (White) and Jet Black Polyester (Black) are UL Listed as corrosion resistant. Temperature options include 135F (57C), 155F (68C), 175F (79C), 200F (93C), and 286F (141C). Finish and temperature combinations available in the “Options” section at the top of this product page.

TY313 listed accessories include the W-Type 6 sprinkler wrench, manufacturer part number(s) (56-000-6-387). Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page. Over the years, Tyco™ has acquired Central Sprinkler, Gem Sprinkler Company, Grinnell Corporation, and Star Sprinkler Incorporated, and while these brands are no longer available, Tyco™ has re-designated many of their sprinkler models. Quick-response sprinklers from Gem and Grinnell’s previous Model A line were incorporated into Series TY-FRB. Star’s SG-QR was also re-designated as TY-FRB.

Reviews
No reviews yet
Product Alternatives