*OBSOLETE*Tyco™ TY3131 Upright Sprinkler | QR | 5.6K | White | 135F | 57-370-4-135

SKU:
TY3131WH135
Manufacturer Part Number:
57-370-4-135
$34.91

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
TY3131WH135
Manufacturer Part Number:
57-370-4-135
Manufacturer:
Tyco™
SIN:
TY3131
Model:
TY-FRB
Head Type:
Upright
Finish:
White
Finish Detail:
Signal White Polyester
Size:
1/2 in.
Size Detail:
1/2 in. NPT
K Factor:
5.6K
Response Type:
Quick Response (QR)
Temperature:
135F
Heat Element:
Glass Bulb
Coverage:
Standard Coverage
Material:
Bronze Frame, Copper/Bronze Deflector
Corrosion Resistant:
Yes
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
Yes
Other Listings:
EAC Approved, LPCB, NYC Approved
Maximum Working Water Pressure:
250 PSI (UL) / 175 PSI (FM)
Sourced Location:
USA
Length:
1.63 in. (41.402 mm)
Width:
1.63 in. (41.402 mm)
Height:
2.25 in. (57.15 mm)
Weight:
0.15 lbs. (0.07 kg)

Tyco™ TY3131 White 135F SR Upright 57-370-4-135 Hero Image | QRFS™

Tyco™ TY3131 White 135F SR Upright 57-370-4-135 Hero Image | QRFS™
Tyco™ TY3131 White 135F SR Upright 57-370-4-135 Side Image | QRFS™
Tyco™ TY3131 White 135F SR Upright 57-370-4-135 Alt Side Image | QRFS™
Tyco™ TY3131 White 135F SR Upright 57-370-4-135 Deflector Image | QRFS™
Overview

This product is now obsolete and has been replaced with the TY313. Tyco™ Model TY-FRB Upright Fire Sprinkler Head

Sprinkler Identification Number (SIN): TY3131

This Upright sprinkler features a White finish and a 135°F (57°C) temperature.

This Tyco™ Model TY-FRB Upright Fire Sprinkler is a quick response, standard coverage sprinkler, activating at 135°F with a 5.6 K-Factor. Each upright head features a heat-sensitive 3 mm glass bulb, Standard 1/2 in. NPT threads, and a Bronze frame with Copper deflector.

This is a quick response, standard coverage, upright sprinkler with a maximum working water pressure of 250 PSI. Using a heat-activated glass bulb, this automatic fire sprinkler opens when ambient temperatures reach 135°F, effectively containing the spread of fire.

The TY3131 is installed in the upright position. Refer to the manufacturer data sheet for installation instructions.

Tyco™ Upright Fire Sprinkler (TY3131) Sprinkler Head Listings and Approvals

Each sprinkler head is made by Tyco™, a global leader in fire protection manufacturing for nearly 100 years. When installed properly, this TY3131 maintains the following listings and approvals: UL, C-UL, FM, LPCB, NYC, EAC.
Refer to the datasheet for listings and approvals in specific temperatures and/or applications.

The Tyco™ Upright Sprinkler TY3131 is designed for NFPA 13. Apply the listed areas of coverage and minimum water supply requirements as shown in the datasheet. This Upright sprinkler head has a maximum working pressure of 250 PSI (17.2 BAR) and connects to wet pipe fire protection systems.

Tyco™ TY3131 Automatic Fire Sprinkler Installation and Accessories

During installation, be aware that over-tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer-approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional installation and storage information.

Listed TY3131 Accessories include:

Sprinkler Wrenches:

  • W-Type 6 Standard Sprinkler Wrench

 

Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These are available in the corresponding product category sections.

Available Sprinklers

This upright sprinkler head is also available in Brass and Chrome finishes and in 155F, 175F, 200F, and 286F temperature options.

Reviews
No reviews yet
Product Alternatives