Victaulic™ V33 Cover Plate | Chrome | 135F | 3-1/4 in. OD | S3306A0020

SKU:
11-V-S33-CP135
Manufacturer Part Number:
S3306A0020
$60.39
Data Sheet Product Data Sheet

Select Variation

Want It Customized?
Please Note: Cover plates are designed for specific sprinkler heads. Size alone does not guarantee compatibility. To ensure the correct fit, please use our Sprinkler Cover Plate Finder Tool.

  • Buy 50 - 99 and get 2.5% off
  • Buy 100 or above and get 7.5% off

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
11-V-V33-CP135
Manufacturer Part Number:
S3306A0020
Manufacturer:
Victaulic™
Model:
V33
Installation Type:
Push On
Adjustment:
1/2 in.
Outer Diameter:
3-1/4 in.
Inner Diameter:
2-3/8 in
Finish:
Chrome
Finish Detail:
Chrome Plated
Temperature:
135F
Corrosion Resistant:
No
UL Listed:
Yes
FM Approved:
No
Length:
3.25 in. (82.55 mm)
Width:
3.25 in. (82.55 mm)
Height:
3.03 in. (76.96 mm)

Victaulic™ V33 Cover Plate | Chrome | 135F | QRFS™ | Hero

Victaulic™ V33 Cover Plate | Chrome | 135F | QRFS™ | Hero
Victaulic™ V33 Cover Plate | Chrome | 135F | QRFS™ | Label
Play Button
Overview

Victaulic™ V33 Fire Sprinkler Cover Plate

Victaulic™ V33 Chrome Fire Sprinkler Cover Plate with 135F (57C) activation temperature. This fire sprinkler cover works with Victaulic™’s V33 concealed pendent fire sprinklers.  The V33 cover facilitates timely activation of the V33 concealed fire sprinkler heads with a temperature rating of 135F (57C). This sprinkler cover has an outer diameter of 3-1/4 in. (83 mm).

The Victaulic™ V33 cover plate is perfect for building owners who are considering aesthetics with their fire sprinkler installation; the V38 cover is available in 4 different finishes without incurring additional fees. These finishes include Chrome Plated, Off White Painted, Bright White Painted, and Flat Black Painted.  Along with these base finishes, for an additional fee Victaulic™ will custom paint this cover in any finish you prefer, so long as the paint is from Benjamin Moore or Sherwin-Williams. Contact QRFS™ customer support for more details.

Victaulic™ V33 Fire Sprinkler Cover Plate Sprinkler Head Compatibility and Listings

This Sprinkler Head Cover Plate from Victaulic™ is UL Listed, and/or may be listed/approved by other organizations depending on the sprinkler. It meets the requirements of a sprinkler assembly per NFPA 13, where approved by the local Authority Having Jurisdiction. It installs by simply pushing the cover into the sprinkler’s frame.

To remove your existing cover plate, gently twist the cover to the left while applying downward pressure by pulling gently as you turn.

When this Chrome fire sprinkler cover plate reaches its specified temperature of 135F (57C), the solder holding the plate's decorative exterior on the frame melts, and the two separate. For many cover plates, the rated temperature is at least 20F (6.7C) cooler than the sprinkler head's activation temperature, which ensures that the cover plate detaches early enough to allow the sprinkler to activate on time. However, each manufacturer's product line varies slightly, and cover plate temperatures may be closer to or further away from the fire sprinkler's activation temperature. Use only the cover plate approved by the manufacturer for your specific sprinkler.

Victaulic™ V33 Cover Plate Finishes, Temperatures, and Listed Accessories

This Victaulic™ V33 fire sprinkler cap is available in Chrome Plated, Off White Painted, Bright White Painted, and Flat Black Painted. It is available in two temperatures at 135F (57C). You can choose from all the available options be selecting from the dropdown at the top of the page.

This Victaulic™ V33 Concealed sprinkler head cover is installed easily by hand. Find all related products in the Frequently Bought Together section above.

This Sprinkler Cover Plate fits the following Victaulic™ concealed sprinkler heads:

  • V3102
  • V3104
  • V3301
  • V3302
  • V3303
  • V3304
  • V3517
  • V3518
Reviews
No reviews yet
Product Alternatives