Victaulic™ V2709 Sidewall Sprinkler | SR | 5.6K | White | 135F | S271CAS440

SKU:
V2709WH135
Manufacturer Part Number:
S271CAS440
$27.93
Data Sheet Product Data Sheet

Select Variation

  • Buy 100 - 199 and get 3% off
  • Buy 200 or above and get 7% off

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
V2709WH135
Manufacturer Part Number:
S271CAS440
Replaces Manufacturer Part Numbers:
GL5670
Manufacturer:
Victaulic™
SIN:
V2709
Model:
FireLock FL-SR/SW
Head Type:
Sidewall
Finish:
White
Finish Detail:
White Polyester Painted
Size:
1/2 in.
Size Detail:
1/2 in. NPT Sprinkler
K Factor:
5.6K
Response Type:
Standard Response (SR)
Temperature:
135F
Heat Element:
Glass Bulb
Coverage:
Standard Coverage
Material:
Brass Frame, Bronze Deflector
Corrosion Resistant:
Yes
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
Yes
Maximum Working Water Pressure:
175 PSI
Escutcheon Type:
Recessed
Length:
3 in. (76.2 mm)
Width:
1.25 in. (31.75 mm)
Height:
1.25 in. (31.75 mm)
Weight:
0.21 lb. (0.1 kg)
System Type:
Wet

Victaulic™ V2709 White Horizontal Sidewall 135F | S271CAS440 | Hero | QRFS™

Victaulic™ V2709 White Horizontal Sidewall 135F | S271CAS440 | Hero | QRFS™
Victaulic™ V2709 White Horizontal Sidewall 135F | S271CAS440 | Side | QRFS™
Victaulic™ V2709 White Horizontal Sidewall 135F | S271CAS440 | Deflector | QRFS™
Victaulic™ V2709 Sidewall Sprinkler | SR | 5.6K | White | 135F | S271CAS440
Play Button
Overview

Victaulic™ FireLock FL-SR/SW (V2709) Horizontal Sidewall Fire Sprinkler Head

This Victaulic™ FL-SR/SW White Horizontal Sidewall Fire Sprinkler features a glass bulb activating at 135F (57C) with a 5.6 K-Factor, and 1/2 in. NPT threads. Each sidewall head features a brass frame and bronze deflector. The manufacturer part number is S271CAS440, and the Sprinkler Identification Number (SIN) is V2709. In 2019, Victaulic™ purchased fire sprinkler company Globe. The Globe Equivalent to this sprinkler is GL5670.

Using a heat-activated glass bulb assembly, this automatic fire sprinkler opens when ambient temperatures reach 135F (57C), drenching the area surrounding a fire to keep it in its place of origin. For recessed sidewall application, refer to data sheet for installation with the Victaulic™ V27 Recessed Escutcheon.

Victaulic™ Horizontal Sidewall Fire Sprinkler FL-SR/SW (V2709) Sprinkler Head Listings and Approvals

Each FL-SR/SW sprinkler is made by Victaulic™, a global leader in fire-suppression products. This sidewall fire sprinkler head maintains Approvals or Listings from cULus (4-12 in. deflector distance, excl. 286F and 360F with escutcheon), FM (no escutcheon, 1/2 in. escutcheon only, excl. 286F and 360F), LPCB (no escutcheon), and CE (no escutcheon).

The V2709 is a commercial sprinkler and is cULus listed for use when installed in accordance with NFPA 13 requirements for wet pipe sprinkler systems and designed for use in commercial occupancies. This horizontal sidewall sprinkler head has a maximum working pressure of 175 PSI (12.1 BAR) FM and connects to wet piping systems.

Victaulic™ FL-SR/SW (V2709) Sidewall Head Sprinkler Installation and Other Information

During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional storage and installation information.

This sidewall sprinkler features a white finish and a 135F (57C) temperature. Available finish options include Brass, Chrome, White, and Black. White Polyester Painted (White) and Flat Black Polyester Painted (Black) are UL Listed as corrosion resistant. Temperature options include 135F (57C), 155F (68C), 175F (79C), 200F (93C), 286F (141C), and 360F (182C). Finish and temperature combinations available in the “Options” section at the top of this product page.

V2709 listed accessories include the V27-2 Recessed and V27 Open End sprinkler wrenches and the V27 Recessed Escutcheon. Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page.