Victaulic™ V3408 Pendent Sprinkler | QR | 11.2K | Brass | 175F | S34-2BEQ610

SKU:
V3408BR175
Manufacturer Part Number:
S34-2BEQ610
$124.60

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
V3408BR175
Manufacturer Part Number:
S34-2BEQ610
Manufacturer:
Victaulic™
SIN:
V3408
Model:
Series FL-QR/ST/INT
Head Type:
Pendent
Finish:
Brass
Finish Detail:
Plain Brass
Size:
3/4 in.
Size Detail:
3/4 in. NPT
K Factor:
11.2K
Response Type:
Quick Response (QR)
Temperature:
175F
Heat Element:
Glass Bulb
Coverage:
Standard Coverage
Material:
Brass Frame, Bronze Deflector
Corrosion Resistant:
No
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
Yes
Other Listings:
cULus
Maximum Working Water Pressure:
250 PSI UL / 175 PSI FM
Sourced Location:
USA
System Type:
Wet

Victaulic™ V3408 Pendent Sprinkler | QR | 11.2K | Brass | 175F | S34-2BEQ610

Victaulic™ V3408 Pendent Sprinkler | QR | 11.2K | Brass | 175F | S34-2BEQ610
Victaulic™ V3408 Pendent Sprinkler | QR | 11.2K | Brass | 175F | S34-2BEQ610
Victaulic™ V3408 Pendent Sprinkler | QR | 11.2K | Brass | 175F | S34-2BEQ610
Victaulic™ V3408 Pendent Sprinkler | QR | 11.2K | Brass | 175F | S34-2BEQ610
Overview

Victaulic Series FL-QR/ST/INT Quick Response (QR) Pendent (V3408) Fire Sprinkler Head

This Victaulic Quick Response (QR) Pendent Fire Sprinkler features a glass bulb activating at 175F with a 11.2 K-Factor, and 3/4 in. threads. Each Pendent head features a Brass Frame, Bronze Deflector, and the Sprinkler Identification Number (SIN) is V3408. This is a Quick Response (QR), Standard Coverage sprinkler with a maximum working water pressure of 250PSI (UL), 175PSI (FM).

The Series FL-QR/ST/INT Pendent sprinkler delivers effective, affordable defense against fire. Using a heat-activated Glass Bulb assembly, this automatic fire sprinkler opens when ambient temperatures reach 175F, drenching the area surrounding a fire to keep it in its place of origin.

Victaulic Series FL-QR/ST/INT Quick Response (QR) Pendent (V3408) Sprinkler Head Listings and Approvals

Each Series FL-QR/ST/INT Pendent sprinkler is made by Victaulic, a global leader in fire protection manufacturing. When installed properly, this fire sprinkler head is UL, FM, cULus listed. Refer to the datasheet for listings and approvals in specific temperatures and/or applications.

This Pendent fire sprinkler is designed to connect seamlessly to wet piping systems, providing dependable fire suppression when it matters most. Engineered for high performance, it delivers fast and uniform water distribution during emergency activation. Built for long-term reliability, this sprinkler head requires minimal maintenance and supports quick, straightforward installation. Whether you're replacing an existing unit or installing a new system, this fire sprinkler meets key industry safety standards and enhances overall fire protection efficiency.

Victaulic Series FL-QR/ST/INT (V3408) Pendent Sprinkler Installation and Other Information

- Care:

Be careful when handling, as over-tightening can damage the 3/4 in. threads or the sprinkler itself. Avoid dropping or exposing the sprinkler to unnecessary impact, which could affect performance. Do not install if the unit appears damaged or compromised in any way. Store in a clean, dry environment to prevent contamination or mechanical damage. Always refer to the datasheet for proper storage and installation guidelines to ensure optimal performance and compliance with safety standards.

- Finishes & Temperatures

This Pendent sprinkler features a Plain brass finish and activates at 175F. Available finish options include Plain brass.

Temperature options include 135F, 155F, 175F, 200F, 286F.

- Accessories

The Series FL-QR/ST/INT (V3408) listed accessories include: V27 Guard/Shield, V34 Guard/Shield, V27 Open End, V34 Open End, 3/16" Hex-Bit (V9).

Reviews
No reviews yet
Product Alternatives