Victaulic™ V3802 Concealed Pendent Sprinkler | QR | 5.6K | 155F | S381PCQ410

SKU:
V3802CP155
Manufacturer Part Number:
S381PCQ410
$25.25
    • Buy 100 - 199 and get 3% off
    • Buy 200 or above and get 7% off

    FAST SHIPPING: In stock items ship SAME DAY if ordered before 3PM EST via UPS.

    RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

    Specifications
    QRFS™ SKU:
    V3802CP155
    Manufacturer Part Number:
    S381PCQ410
    Replaces Manufacturer Part Numbers:
    GL5604
    Manufacturer:
    Victaulic™
    SIN:
    V3802
    Model:
    FireLock FL-QR/C
    Head Type:
    Concealed Pendent
    Size:
    1/2 in.
    Size Detail:
    1/2 in. NPT Sprinkler
    K Factor:
    5.6K
    Response Type:
    Quick Response (QR)
    Temperature:
    155F
    Heat Element:
    Glass Bulb
    Coverage:
    Standard Coverage
    Material:
    Brass Frame, Bronze Deflector
    Corrosion Resistant:
    No
    May Contain Lead:
    Yes
    UL Listed:
    Yes
    FM Approved:
    Yes
    Maximum Working Water Pressure:
    175 PSI
    Length:
    3.25 in. (82.55 mm)
    Width:
    3.25 in. (82.55 mm)
    Height:
    2.38 in. (60.45 mm)
    Weight:
    0.32 lb. (0.15 kg)
    Finish:
    Brass

    Victaulic™ V3802 Concealed Pendent | 155F | S381PCQ410 | Hero

    Replaces GL5604
    Victaulic™ V3802 Concealed Pendent | 155F | S381PCQ410 | Hero
    Victaulic™ V3802 Concealed Pendent | 155F | S381PCQ410 | With Sprinkler
    Victaulic™ V3802 Concealed Pendent | 155F | S381PCQ410 | Deflector
    Play Button
    Overview

    Victaulic™ FireLock FL-QR/C (V3802) QR Concealed Pendent Fire Sprinkler Head

    This Victaulic™ FL-QR/C Concealed Pendent Quick Response Fire Sprinkler features a glass bulb activating at 155F (68C) with a 5.6 K-Factor, and 1/2 in. NPT threads. Each concealed pendent head features a brass frame and bronze deflector. This sprinkler was designed to be covered by a Victaulic™ V38 cover plate, allowing for optimal aesthetics and proper function. The manufacturer part number is S381PCQ410, and the Sprinkler Identification Number (SIN) is V3802. In 2019, Victaulic™ purchased fire sprinkler company Globe. The Globe Equivalent to this sprinkler is GL5604.

    Using a heat-activated glass bulb assembly, this automatic fire sprinkler opens when ambient temperatures reach 155F (68C), drenching the area surrounding a fire to keep it in its place of origin.

    Victaulic™ Concealed Pendent Fire Sprinkler FL-SR/C (V3802) Sprinkler Head Listings and Approvals

    Each FL-QR/C sprinkler is made by Victaulic™, a global leader in fire-suppression products. This concealed pendent fire sprinkler head maintains UL Listing as Quick Response and is FM Approved as Standard Response.

    The V3802 is a commercial sprinkler and is cULus listed for use when installed in accordance with NFPA 13 requirements for wet pipe sprinkler systems and designed for use in commercial occupancies. This commercial sprinkler head has a maximum working pressure of 175 PSI (12.1 BAR) UL and connects to wet piping systems.

    Victaulic™ FL-SR/C (V3802) Concealed Sprinkler Head Installation and Other Information

    During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional storage and installation information.

    This concealed pendent sprinkler head is available at temperatures of 135F (57C), 155F (68C), 175F (79C), and 200F (93C) and must be paired with a Victualic V38 Cover Plate. These cover plates come in a variety of finishes: Chrome Plated, White Painted, and Flat Black Painted, and come in two temperatures: 135F (57C) and 165F (74C). To choose your cover plate, find the “Options” section at the top of this product page.

    V3802 listed accessories include the V38 Concealed sprinkler wrench and is commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page.