Victaulic™ V38 Cover Plate | Chrome | 165F | 3-1/4 in. OD | S3806D0020

SKU:
11-V-S38-CP165
Manufacturer Part Number:
S3806D0020
$29.50
Data Sheet Product Data Sheet

Select Variation

Want It Customized?
Please Note: Cover plates are designed for specific sprinkler heads. Size alone does not guarantee compatibility. To ensure the correct fit, please use our Sprinkler Cover Plate Finder Tool.

  • Buy 50 - 99 and get 2.5% off
  • Buy 100 or above and get 7.5% off

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
11-V-S38-CP165
Manufacturer Part Number:
S3806D0020
Manufacturer:
Victaulic™
Model:
V38
Installation Type:
Thread On
Adjustment:
1/2 in.
Outer Diameter:
3-1/4 in.
Inner Diameter:
2-3/8 in.
Finish:
Chrome
Finish Detail:
Chrome Plated
Temperature:
165F
Corrosion Resistant:
No
UL Listed:
Yes
FM Approved:
No
Length:
3.25 in. (82.55 mm)
Width:
3.25 in. (82.55 mm)
Height:
1.16 in. (29.46 mm)
Weight:
0.18 lb. (0.08 kg)

Victaulic™ V38 Cover Plate | Chrome | 165F | QRFS™ | Hero

Victaulic™ V38 Cover Plate | Chrome | 165F | QRFS™ | Hero
Victaulic™ V38 Cover Plate | Chrome | 165F | QRFS™ | Side
Victaulic™ V38 Cover Plate | Chrome | 165F | QRFS™ | Family
Play Button
Overview

Victaulic™ V38 Fire Sprinkler Cover Plate

Victaulic™ V38 Chrome Fire Sprinkler Cover Plate with 165F (74C) activation temperature. This fire sprinkler cover works with Victaulic™’s V38 concealed pendent fire sprinklers.  The V38 cover facilitates timely activation of the V38 concealed fire sprinkler heads with a temperature rating of 135F (57C) or 165F (74C). This sprinkler cover has an outer diameter of 3-1/4 in. (83 mm).

The Victaulic™ V38 cover plate is perfect for building owners who are considering aesthetics with their fire sprinkler installation; the V38 cover is available in 3 different finishes without incurring additional fees. These finishes include Chrome Plated, Bright White Painted, and Flat Black Painted.  Along with these base finishes, for an additional fee Victaulic™ will custom paint this cover in any finish you prefer, so long as the paint is from Benjamin Moore or Sherwin-Williams. Contact QRFS™ customer support for more details.

Victaulic™ V38 Fire Sprinkler Head Cover Plate Compatibility and Listings

This Sprinkler Head Cover Plate from Victaulic™ is UL Listed, and/or may be listed/approved by other organizations depending on the sprinkler. It meets the requirements of a sprinkler assembly per NFPA 13, where approved by the local Authority Having Jurisdiction. It installs by simply screwing the cover into the sprinkler’s frame.

To remove your existing cover plate, gently twist the cover to the left while applying downward pressure by pulling gently as you turn.

When this Chrome fire sprinkler cover plate reaches its specified temperature of 135F (57C) or 165 (74C), the solder holding the plate's decorative exterior on the frame melts, and the two separate. For many cover plates, the rated temperature is at least 20F (6.7C) cooler than the sprinkler head's activation temperature, which ensures that the cover plate detaches early enough to allow the sprinkler to activate on time. However, each manufacturer's product line varies slightly, and cover plate temperatures may be closer to or further away from the fire sprinkler's activation temperature. Use only the cover plate approved by the manufacturer for your specific sprinkler.

Victaulic™ V38 Cover Plate Finishes, Temperatures, and Listed Accessories

This Victaulic™ V38 fire sprinkler cap is available in Chrome Plated, Bright White Painted, and Flat Black Painted. It is available in two temperatures at 135F (57C) and 165F (74C). You can choose from all the available options be selecting from the dropdown at the top of the page.

This Victaulic™ V38 Concealed sprinkler head cover is installed easily by hand. Find all related products in the Frequently Bought Together section above.

This Sprinkler Cover Plate fits the following Victaulic™ concealed sprinkler heads:

  • V3801
  • V3802
  • V3804
  • V3806
  • V3807
  • V3808
Reviews
No reviews yet
Product Alternatives