Victaulic™ V4808 Pendent Sprinkler | Fast Response | 22.4K | Brass | 165F | S48-3BDRM10

SKU:
V4808BR165
Manufacturer Part Number:
S48-3BDRM10
$104.72

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
V4808BR165
Manufacturer Part Number:
S48-3BDRM10
Manufacturer:
Victaulic™
SIN:
V4808
Model:
Series FL-QR/ST/ESFR
Head Type:
Pendent
Finish:
Brass
Finish Detail:
Plain brass
Size:
1 in.
Size Detail:
1 in. NPT
K Factor:
22.4K
Response Type:
Fast Response
Temperature:
165F
Heat Element:
Fusible Link
Coverage:
Standard Coverage
Material:
Brass Frame, Brass Deflector
Corrosion Resistant:
No
May Contain Lead:
Yes
UL Listed:
No
FM Approved:
Yes
Maximum Working Water Pressure:
175 PSI
Sourced Location:
USA
System Type:
Wet

Victaulic™ V4808 Pendent Sprinkler | Fast Response | 22.4K | Brass | 165F | S48-3BDRM10

Victaulic™ V4808 Pendent Sprinkler | Fast Response | 22.4K | Brass | 165F | S48-3BDRM10
Victaulic™ V4808 Pendent Sprinkler | Fast Response | 22.4K | Brass | 165F | S48-3BDRM10
Victaulic™ V4808 Pendent Sprinkler | Fast Response | 22.4K | Brass | 165F | S48-3BDRM10
Victaulic™ V4808 Pendent Sprinkler | Fast Response | 22.4K | Brass | 165F | S48-3BDRM10
Overview

Victaulic Series FL-QR/ST/ESFR Fast Response Pendent (V4808) Fire Sprinkler Head

This Victaulic Fast Response Pendent Fire Sprinkler features a glass bulb activating at 165F with a 22.4 K-Factor, and 1 in. threads. Each Pendent head features a Brass Frame, Brass Deflector, and the Sprinkler Identification Number (SIN) is V4808. This is a Fast Response, Standard Coverage sprinkler with a maximum working water pressure of 175PSI (UL).

The Series FL-QR/ST/ESFR Pendent sprinkler delivers effective, affordable defense against fire. Using a heat-activated Fusible Link assembly, this automatic fire sprinkler opens when ambient temperatures reach 165F, drenching the area surrounding a fire to keep it in its place of origin.

Victaulic Series FL-QR/ST/ESFR Fast Response Pendent (V4808) Sprinkler Head Listings and Approvals

Each Series FL-QR/ST/ESFR Pendent sprinkler is made by Victaulic, a global leader in fire protection manufacturing. When installed properly, this fire sprinkler head is FM listed. Refer to the datasheet for listings and approvals in specific temperatures and/or applications.

This Pendent fire sprinkler is designed to connect seamlessly to wet piping systems, providing dependable fire suppression when it matters most. Engineered for high performance, it delivers fast and uniform water distribution during emergency activation. Built for long-term reliability, this sprinkler head requires minimal maintenance and supports quick, straightforward installation. Whether you're replacing an existing unit or installing a new system, this fire sprinkler meets key industry safety standards and enhances overall fire protection efficiency.

Victaulic Series FL-QR/ST/ESFR (V4808) Pendent Sprinkler Installation and Other Information

- Care:

Be careful when handling, as over-tightening can damage the 1 in. threads or the sprinkler itself. Avoid dropping or exposing the sprinkler to unnecessary impact, which could affect performance. Do not install if the unit appears damaged or compromised in any way. Store in a clean, dry environment to prevent contamination or mechanical damage. Always refer to the datasheet for proper storage and installation guidelines to ensure optimal performance and compliance with safety standards.

- Finishes & Temperatures

This Pendent sprinkler features a Plain brass finish and activates at 165F. Available finish options include Plain brass.

Temperature options include 165F, 212F.

- Accessories

The Series FL-QR/ST/ESFR (V4808) listed accessories include: V46 Open End, 3/16" Hex-Bit (V9).