Viking G-1 Fire Sprinkler Escutcheon
This Viking G-1 Vaulted and Sloped Ceiling Sprinkler Head Escutcheon features an aesthetically pleasing white finish on steel, has an outer diameter of 4 in. and a 5/8 in. adjustment. This two-piece non-split escutcheon is available for certain Viking fire sprinklers with a 1/2 in. or 3/4 in. orifice and has a vertical adjustment up to 5/8 in with ceilings sloped up to 8/12 (33.7 Degrees). These allow for horizontal sidewall sprinklers to be recessed up to 1/2 in. depending on the degree of slope. These Viking G-1 escutcheons are Push On design, meaning you simply push into the sprinkler’s adapter to install.
The Viking G-1 Escutcheon for sprinkler heads guarantees proper sprinkler head activation by covering the gap left by a hole saw when a fire sprinkler is installed. Keep your system compliant by using the listed fire sprinkler escutcheon for your sprinkler.
Viking G-1 Escutcheon Compatibility, Listings, and Other Information
Sprinkler Identification Numbers compatible with this Viking G-1 Escutcheon include:
VK104, VK112, VK2753, VK2773, VK2793, VK305, VK307, VK308, VK319, VK320, VK333, VK334, VK344, VK346, VK360, VK460, VK479, VK484, VK4840, VK486, VK4860, VK605, VK606, VK609, VK612, VK613, VK630, VK638
When combined with a listed sprinkler head, this vaulted and sloped ceiling escutcheon may carry listings from UL, FM and/or other organizations, depending on the sprinkler it is installed with. Refer to the specific sprinkler’s technical datasheet for specific approvals. Whether you’re installing a new fire sprinkler system or just need replacement fire sprinkler head escutcheons, be sure that it works with your model sprinkler!
Viking G-1 escutcheons made of Steel and are available in four finishes including Bright Brass, Polished Chrome, White Polyester, and Black Polyester. These escutcheons are to be installed with manufacturer defined fire sprinkler heads with a 1/2 in. or 3/4 in. orifice. See list above to check for sprinkler head compatibility.
Viking recessed and adjustable escutcheons provide a low-profile decorative recessed sprinkler installation. These two-piece escutcheons allow installation and testing of the sprinklers prior to installing the ceiling or wall, and are made to allow for minor adjustments due to pipe or ceiling pitch. These escutcheons can be removed and reinstalled, allowing access above removable ceiling panels for servicing building equipment without shutting down the sprinkler system and removing the sprinkler.
QRFS SKU: |
12-VK-G1ST-WH50 |
Manufacturer Part Number: |
14315M/W |
Manufacturer: |
Viking |
Model: |
G-1 |
Installation Type: |
Push On |
Adjustment: |
5/8 in. |
Outer Diameter: |
4 in. |
Inner Diameter: |
2-5/8 in. |
Sprinkler Size: |
1/2 in. Sprinkler |
Finish: |
White |
Finish Detail: |
White Polyester |
Corrosion Resistant: |
Yes |
UL Listed: |
Yes |
FM Approved: |
Yes |
Length: |
4 in. (101.6 mm) |
Width: |
4 in. (101.6 mm) |
Height: |
1.43 in. (36.32 mm) |
Weight: |
0.36 lb. (0.16 kg) |
Box/Pack Quantity: |
200 |