SALE

Viking™ VK4700 Pendent Lead Free Sprinkler | Residential | 3.0K | Brass | 155F | 17492AB

SKU:
VK4700BR155
Manufacturer Part Number:
17492AB
$38.99
$23.39
  • Viking™ F-1 Escutcheon | Bright Brass | 1/2 in. Sprinkler | QRFS™ | Hero
  • Viking™ E-1 Escutcheon | Bright Brass | 1/2 in. Sprinkler | QRFS™ | Hero
  • Buy 50 - 99 and get 3% off
  • Buy 100 or above and get 7% off

FAST SHIPPING: In stock items ship SAME DAY if ordered before 3PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
VK4700BR155
Manufacturer Part Number:
17492AB
Manufacturer:
Viking™
SIN:
VK4700
Model:
Freedom Lead Free
Head Type:
Pendent
Finish:
Brass
Finish Detail:
Brass
Size:
1/2 in.
Size Detail:
1/2 in. NPT Sprinkler
K Factor:
3.0K
Response Type:
Residential
Temperature:
155F
Heat Element:
Glass Bulb
Coverage:
Standard Coverage
Material:
Brass Frame, Brass Deflector
Corrosion Resistant:
No
May Contain Lead:
No
UL Listed:
Yes
FM Approved:
No
Maximum Working Water Pressure:
175 PSI
Escutcheon Type:
Recessed or Surface Mounted
Length:
1.15 in. (29.21 mm)
Width:
1.35 in. (34.29 mm)
Height:
2.25 in. (57.15 mm)
Weight:
0.14 lb. (0.06 kg)

Viking™ VK4700 Pendent Lead Free Sprinkler | Residential | 3.0K | Brass | 155F | 17492AB | QRFS™ | Hero

Viking™ VK4700 Pendent Lead Free Sprinkler | Residential | 3.0K | Brass | 155F | 17492AB | QRFS™ | Hero
Viking™ VK4700 Pendent Lead Free Sprinkler | Residential | 3.0K | Brass | 155F | 17492AB | QRFS™ | Side
Viking™ VK4700 Pendent Lead Free Sprinkler | Residential | 3.0K | Brass | 155F | 17492AB | QRFS™ | Deflector
Play Button
Overview

Viking™ Freedom Residential Pendent Lead Free 3.0 K-Factor (VK4700) Fire Sprinkler Head

This Viking™ Freedom Residential Lead Free Pendent Fire Sprinkler features a glass bulb activating at 155F (68C) with a 3.0 K-Factor, and 1/2 in. NPT threads. Each pendent head features a brass frame and bronze deflector. The Sprinkler Identification Number (SIN) is VK4700. This is a residential response, standard coverage sprinkler with a maximum working water pressure of 175 PSI.

The VK4700 lead free pendent sprinkler delivers effective, affordable defense against fire in residential occupancies. Using a heat-activated glass bulb assembly, this automatic fire sprinkler opens when ambient temperatures reach 155F (68C), drenching the area surrounding a fire to keep it in its place of origin. For recessed application, refer to data sheet for installation instructions with the approved Viking™ escutcheon(s).

Viking™ Lead Free Pendent Fire Sprinkler Freedom (VK4700) Sprinkler Head Listings and Approvals

Each Freedom lead free sprinkler is made by Viking™, a global leader in fire protection manufacturing for nearly 100 years. When installed properly, this fire sprinkler head maintains listings and approvals from cULus (Category VKKW). Refer to the datasheet for listings and approvals in specific temperatures and/or applications.

This lead free pendent sprinkler head has a maximum working pressure of 175 PSI (12.1 BAR) UL and connects to wet piping systems.

Viking™ Freedom (VK4700) 3.0K Lead Free Pendent Sprinkler Installation and Other Information

During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional storage and installation information.

This residential lead free pendent sprinkler features a brass finish and a 155F (68C) temperature. Available finish options include Brass, Chrome, White, and Black. White Polyester Painted (White), and Flat Black Polyester Painted (Black) are UL Listed as corrosion resistant. Temperature options include 155F (68C) and 175F (79C). Finish and temperature combinations available in the “Options” section at the top of this product page.

The VK4700 listed accessories include the approved Viking™ Wrench (part no. 21475M/B), Viking™ Recessed Wrench (part no. 13655W/B), and the approved Viking™ Escutcheon(s). Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page.

Reviews
No reviews yet
Product Alternatives