Viking™ VK600 Pendent Sprinkler | EC/QREC | 5.6K | Chrome | 155F | 06778BFB

SKU:
VK600CH155
Manufacturer Part Number:
06778BFB
$44.25
Data Sheet Product Data Sheet

Select Variation

  • Buy 50 - 99 and get 3% off
  • Buy 100 or above and get 7% off

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
VK600CH155
Manufacturer Part Number:
06778BFB
Manufacturer:
Viking™
SIN:
VK600
Model:
Microfast SR/QR EC
Head Type:
Pendent
Finish:
Chrome
Finish Detail:
Chrome
Size:
1/2 in.
Size Detail:
1/2 in. NPT Sprinkler
K Factor:
5.6K
Response Type:
Quick Response (QR)
Temperature:
155F
Heat Element:
Glass Bulb
Coverage:
Extended Coverage
Material:
Brass Frame, Brass Deflector
Corrosion Resistant:
No
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
Yes
Maximum Working Water Pressure:
175 PSI
Escutcheon Type:
Recessed or Surface Mounted
Length:
1.38 in. (35.05 mm)
Width:
1.38 in. (35.05 mm)
Height:
2.31 in. (58.67 mm)
Weight:
0.2 lb. (0.09 kg)
System Type:
Wet

Viking™ VK600 Pendent Sprinkler | EC/QREC | 5.6K | Chrome | 155F | 06778BFB | QRFS™ | Hero

Viking™ VK600 Pendent Sprinkler | EC/QREC | 5.6K | Chrome | 155F | 06778BFB | QRFS™ | Hero
Viking™ VK600 Pendent Sprinkler | EC/QREC | 5.6K | Chrome | 155F | 06778BFB | QRFS™ | Side
Viking™ VK600 Pendent Sprinkler | EC/QREC | 5.6K | Chrome | 155F | 06778BFB | QRFS™ | Deflector
Viking™ VK600 Pendent Sprinkler | EC/QREC | 5.6K | Chrome | 155F | 06778BFB | QRFS™ | Family
Overview

Viking™ Microfast EC/QREC Extended Coverage Pendent (VK600) Fire Sprinkler Head

This Viking™ Microfast Standard/Quick Response Extended Coverage (QREC) Pendent Fire Sprinkler features a glass bulb activating at 155F (68C) with a 5.6 K-Factor, and 1/2 in. NPT threads. Each pendent head features a brass frame and brass deflector. The Sprinkler Identification Number (SIN) is VK600. The response type of this sprinkler is dependent upon its installation and application – see Approval Charts in the datasheet for more information. This is an extended coverage sprinkler with a maximum working water pressure of 175 PSI.

The VK600 EC/QREC sprinkler delivers effective, affordable defense against fire in light (UL) hazard occupancies. Using a heat-activated glass bulb assembly, this automatic fire sprinkler opens when ambient temperatures reach 135F (57C), drenching the area surrounding a fire to keep it in its place of origin. For recessed application, refer to data sheet for installation instructions with the approved Viking™ escutcheon(s).

Viking™ Pendent EC/QREC Fire Sprinkler Microfast (VK600) Sprinkler Head Listings and Approvals

Each Microfast pendent sprinkler is made by Viking™, a global leader in fire protection manufacturing for nearly 100 years. When installed properly, this fire sprinkler head maintains listings and approvals from cULus (Category VNIV, Light hazard occupancies only), FM (Class 2020). Refer to the datasheet for listings and approvals in specific temperatures and/or applications.

Standard/Quick Response Extended Coverage Pendent Sprinkler VK600 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for extended coverage pendent spray sprinklers.

Quick Response Extended Coverage Pendent Sprinkler VK600 is FM Approved as a quick response Non-Storage extended coverage pendent sprinkler as indicated in the FM Approval Guide in the datasheet.

This EC/QREC sprinkler head has a maximum working pressure of 175 PSI (12.1 BAR) UL, FM and connects to wet piping systems.

Viking™ Microfast (VK600) Pendent EC/QREC Sprinkler Installation and Other Information

During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional storage and installation information.

This extended coverage sprinkler features a chrome finish and a 155F (68C) temperature. Available finish options include Brass, Chrome, White, and Black. White Polyester Painted (White), and Flat Black Polyester Painted (Black) are UL Listed as corrosion resistant. Temperature options include 135F (57C), 155F (68C), and 175F (79C). Finish and temperature combinations available in the “Options” section at the top of this product page.

The VK600 listed accessories include the approved Viking™ Wrench (part no. 21475M/B), Viking™ Recessed Wrench (part no. 13577W/B), and the approved Viking™ Escutcheon(s). Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page.

Reviews
No reviews yet
Product Alternatives