Viking™ VK427 Institutional Horizontal Sidewall Sprinkler | QR | 5.6K | Grey | 205F | 22885ME/RAL9006

SKU:
VK427GR205
Manufacturer Part Number:
22885ME/RAL9006
$137.47
Data Sheet Product Data Sheet

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
VK427GR205
Manufacturer Part Number:
22885ME/RAL9006
Manufacturer:
Viking™
SIN:
VK427
Model:
Institutional
Head Type:
Institutional Horizontal Sidewall
Finish:
Grey
Finish Detail:
Painted Grey
Size:
1/2 in.
Size Detail:
1/2 in. NPT Sprinkler
K Factor:
5.6K
Response Type:
Quick Response (QR)
Temperature:
205F
Heat Element:
Fusible Link
Coverage:
Standard Coverage
Material:
Brass Frame, Copper Deflector
Corrosion Resistant:
No
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
No
Occupancy Type:
Light, Ordinary Hazard
Maximum Working Water Pressure:
175 PSI
Escutcheon Type:
Flush
Sourced Location:
USA
Length:
2.15 in. (54.61 mm)
Width:
2.15 in. (54.61 mm)
Height:
1.48 in. (37.592 mm)
Weight:
0.51 lbs. (0.23 kg)
System Type:
Wet

Viking™ VK427 Institutional Horizontal Sidewall Sprinkler | QR | 5.6K | Grey | 205F | 22885ME/RAL9006 | QRFS™ | Hero

Viking™ VK427 Institutional Horizontal Sidewall Sprinkler | QR | 5.6K | Grey | 205F | 22885ME/RAL9006 | QRFS™ | Hero
Viking™ VK427 Institutional Horizontal Sidewall Sprinkler | QR | 5.6K | Grey | 205F | 22885ME/RAL9006 | QRFS™ | Front
Viking™ VK427 Institutional Horizontal Sidewall Sprinkler | QR | 5.6K | Grey | 205F | 22885ME/RAL9006 | QRFS™ | Deflector
Viking™ VK427 Institutional Horizontal Sidewall Sprinkler | QR | 5.6K | Grey | 205F | 22885ME/RAL9006 | QRFS™ | Assembled w/ 3in. Escutcheon
Viking™ VK427 Institutional Horizontal Sidewall Sprinkler | QR | 5.6K | Grey | 205F | 22885ME/RAL9006 | QRFS™ | Pair
Overview

Viking™ Institutional Quick Response Horizontal Sidewall (VK427) Fire Sprinkler Head

Sprinkler Identification Number (SIN): VK427

  • This item must be installed with an approved Viking™ Escutcheon. Sold Separately.
    Refer to the datasheet for additional information.
  • The VK427 is FM Approved as Standard Response (SR)

This Viking™ Institutional Horizontal Sidewall Fire Sprinkler is a standard coverage, flush horizontal sidewall sprinkler, activating at 205F (96C) with a 5.6 K-Factor, and is rated for Light and Ordinary Hazard occupancies.  Each Horizontal Sidewall head features heat-sensitive fusible link assembly, standard 1/2 in. NPT threads, and a brass frame with copper deflector.

This is a quick response, or standard response (FM Approved SR Only), standard coverage, institutional sprinkler with a maximum working water pressure of 175 PSI. The VK427 Institutional Sprinkler features a tamper-resistant design, making it a safe and effective choice for use with concealed piping in various institutional mental health occupancies, correctional facilities, or other settings where flush, tamper-resistant sprinklers may be required.

Using a heat-activated fusible link assembly, this automatic fire sprinkler opens when ambient temperatures reach 205F (96C), drenching the area surrounding a fire to keep it in its place of origin. The VK427 is installed flush using one of Viking™’s 3 in. or 4 in. escutcheon plates, leaving exposed only a small portion of the fusible link assembly to ensure the timely activation of the fire sprinkler. Refer to the manufacturer data sheet for installation instructions with the approved Viking™ escutcheon(s).

Viking™ Flush Institutional Fire Sprinkler (VK427) Sprinkler Head Listings and Approvals

Each institutional sprinkler is made by Viking™, a global leader in fire protection manufacturing for nearly 100 years. When installed properly, this VK427 fire sprinkler head maintains listings and approvals from cULus (Category VKKW). Refer to the datasheet for listings and approvals in specific temperatures and/or applications.

The Viking™ Institutional Horizontal Sidewall Sprinkler VK427 is designed for NFPA 13. Apply the listed areas of coverage and minimum water supply requirements as shown in the Approval Chart on Page 8 of the datasheet. This Horizontal Sidewall sprinkler head has a maximum working pressure of 175 PSI (12.1 BAR) and connects to fixed fire protection systems (wet, dry, deluge, or pre-action systems).

Viking™ Institutional (VK427) QR Horizontal Sidewall Sprinkler Installation and Other Information

During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional installation and storage information.

This Institutional Horizontal Sidewall sprinkler features a Grey finish and a 205F (96C) temperature.
Available finishes include Chrome, White, and Grey. Temperature options include 165F (73C) and 205F (96C).
Finish and temperature combinations available in the “Options” section at the top of this product page.

The listed VK427 accessories include the approved Viking™ Institutional Wrench (PN. 22847MB) and the approved Viking™ Institutional 3 in. (PN. 23196-) or 4 in. (PN. 23197-) Escutcheon(s). Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page.

Reviews
No reviews yet
Product Alternatives