Viking™ VK460 Sidewall Sprinkler | Residential | 5.8K | Black | 175F | 13933MD/B-TQ

SKU:
VK460BL175
Manufacturer Part Number:
13933MD/B-TQ
$40.23
Data Sheet Product Data Sheet

Select Variation

  • Buy 50 - 99 and get 3% off
  • Buy 100 or above and get 7% off

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
VK460BL175
Manufacturer Part Number:
13933MD/B-TQ
Manufacturer:
Viking™
SIN:
VK460
Model:
Freedom
Head Type:
Sidewall
Finish:
Black
Finish Detail:
Black Polyester
Size:
1/2 in.
Size Detail:
1/2 in. NPT Sprinkler
K Factor:
5.8K
Response Type:
Residential
Temperature:
175F
Heat Element:
Glass Bulb
Coverage:
Standard Coverage
Material:
Brass Frame, Brass Deflector
Corrosion Resistant:
Yes
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
No
Maximum Working Water Pressure:
175 PSI
Escutcheon Type:
Recessed or Surface Mounted
Length:
2.5 in. (63.5 mm)
Width:
0.88 in. (22.35 mm)
Height:
1.43 in. (36.32 mm)
Weight:
0.17 lb. (0.08 kg)
Original Part Number:
13933MD/B
System Type:
Wet
InstaSeal Compatible:
Yes

Viking™ VK460 Sidewall Sprinkler | Residential | 5.8K | Black | 175F | 13933MD/B | QRFS™ | Hero

Viking™ VK460 Sidewall Sprinkler | Residential | 5.8K | Black | 175F | 13933MD/B | QRFS™ | Hero
Viking™ VK460 Sidewall Sprinkler | Residential | 5.8K | Black | 175F | 13933MD/B | QRFS™ | Side
Viking™ VK460 Sidewall Sprinkler | Residential | 5.8K | Black | 175F | 13933MD/B | QRFS™ | Deflector
Viking™ VK460 Sidewall Sprinkler | Residential | 5.8K | Black | 175F | 13933MD/B | QRFS™ | Family
Play Button
Overview

Viking™ Freedom Residential Horizontal Sidewall (VK460) Fire Sprinkler Head

This Viking™ Freedom Residential Sidewall Fire Sprinkler features a glass bulb activating at 175F (79C) with a 5.8 K-Factor, and 1/2 in. NPT threads. Each horizontal sidewall head features a brass frame and bronze deflector. The Sprinkler Identification Number (SIN) is VK460. This is a residential response, standard coverage sprinkler with a maximum working water pressure of 175 PSI.

The VK460 sidewall sprinkler delivers effective, affordable defense against fire in residential occupancies. Using a heat-activated glass bulb assembly, this automatic fire sprinkler opens when ambient temperatures reach 175F (79C), drenching the area surrounding a fire to keep it in its place of origin. For recessed application, refer to data sheet for installation instructions with the approved Viking™ escutcheon(s).

Viking™ Freedom Horizontal Sidewall Residential Fire Sprinkler (VK460) Sprinkler Head Listings and Approvals

Each Freedom sidewall residential fire sprinkler head is made by Viking™, a global leader in fire protection manufacturing for nearly 100 years. When installed properly, this fire sprinkler head maintains listings and approvals from cULus (Category VKKW) and is VdS Approved. Refer to the datasheet for listings and approvals in specific temperatures and/or applications.

When using Viking™ Residential Sprinkler VK460 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of coverage and minimum water supply requirements shown in the Approval Chart in the datasheet. This sidewall sprinkler head has a maximum working pressure of 175 PSI (12.1 BAR) UL, FM and connects to wet piping systems.

Viking™ Freedom Residential Sidewall (VK460) Sprinkler Installation and Other Information

During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional storage and installation information.

This horizontal sidewall sprinkler features a black finish and a 175F (79C) temperature. Available finish options include Brass, Chrome, White, and Black. White Polyester Painted (White), and Flat Black Polyester Painted (Black) are UL Listed as corrosion resistant. Temperature options include 155F (68C) and 175F (79C). Finish and temperature combinations available in the “Options” section at the top of this product page.

The VK460 listed accessories include the approved Viking™ Wrench (part no. 21475M/B), Viking™ Recessed Wrench (part no. 13655W/B), and the approved Viking™ Escutcheon(s). Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page.

Reviews
No reviews yet
Product Alternatives