Viking™ VK630 Extended Coverage Horizontal Sidewall Sprinkler | QR | 8.0K | Black | 155F | 3/4 in. NPT | 13500MB/B

SKU:
VK630BL155
Manufacturer Part Number:
13500MB/B
$80.65

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
VK630BL155
Manufacturer Part Number:
13500MB/B
Manufacturer:
Viking™
SIN:
VK630
Model:
Microtech
Head Type:
Horizontal Sidewall
Finish:
Black
Finish Detail:
Black Polyester
Size:
3/4 in.
Size Detail:
3/4 in. NPT Sprinkler
K Factor:
8.0K
Response Type:
Quick Response (QR)
Temperature:
155F
Heat Element:
Glass Bulb
Coverage:
Extended Coverage
Material:
Brass Frame, Bronze Deflector
Corrosion Resistant:
No
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
Yes
Occupancy Type:
Light Hazard
Maximum Working Water Pressure:
175 PSI
Sourced Location:
USA
Length:
1.45 in. (36.8 mm)
Width:
1.45 in. (36.8 mm)
Height:
2.64 in. (67.1 mm)
Weight:
0.21 lbs. (0.09 kg)
System Type:
Wet

Viking™ VK630 Extended Coverage Horizontal Sidewall Sprinkler | QR | 8.0K | Black | 155F | 3/4 in. NPT | 13500MB/B | QRFS™ | Hero

Viking™ VK630 Extended Coverage Horizontal Sidewall Sprinkler | QR | 8.0K | Black | 155F | 3/4 in. NPT | 13500MB/B | QRFS™ | Hero
Viking™ VK630 Extended Coverage Horizontal Sidewall Sprinkler | QR | 8.0K | Black | 155F | 3/4 in. NPT | 13500MB/B | QRFS™ | Bottom
Viking™ VK630 Extended Coverage Horizontal Sidewall Sprinkler | QR | 8.0K | Black | 155F | 3/4 in. NPT | 13500MB/B | QRFS™ | Top
Viking™ VK630 Extended Coverage Horizontal Sidewall Sprinkler | QR | 8.0K | Black | 155F | 3/4 in. NPT | 13500MB/B | QRFS™ | Side
Viking™ VK630 Extended Coverage Horizontal Sidewall Sprinkler | QR | 8.0K | Black | 155F | 3/4 in. NPT | 13500MB/B | QRFS™ | Deflector
Overview

Viking™ Extended Coverage QR Horizontal Sidewall (VK630) Fire Sprinkler Head

Sprinkler Identification Number (SIN): VK630

This Horizontal Sidewall sprinkler features a Black finish and 155F (68C) temperature.

This Viking™ VK630 Horizontal Sidewall Fire Sprinkler is a Quick Response, Extended coverage Horizontal Sidewall fire sprinkler head, activating at 155F (68C) with a 8.0 K-Factor. This horizontal sidewall sprinkler head is rated for Light Hazard occupancies only. Each Horizontal Sidewall head features a heat-sensitive glass bulb assembly, standard 3/4 in. NPT threads, and a brass frame with a bronze deflector.

This is a Quick Response Viking™ Horizontal Sidewall sprinkler with a maximum working water pressure of 175 PSI (12 BAR). The VK630 Sprinkler offers reliable fire protection with a sleek, unobtrusive profile. Using a heat-activated glass bulb assembly, this automatic fire sprinkler opens when ambient temperatures reach the sprinkler’s listed activation temperature, drenching the area surrounding a fire to keep it in its place of origin.

Viking™ QR Fire Sprinkler VK630 Sprinkler Head Listings and Approvals

Each sprinkler is made by Viking™, a global leader in fire protection manufacturing. When installed properly, this VK630 fire sprinkler head maintains listings and approvals:

cULus, FM, NYC, China GB

Refer to the datasheet for up-to-date listings and approvals in specific temperatures and/or applications.

When using Viking™ Horizontal Sidewall Sprinkler VK630 for systems designed to NFPA standards, apply the listed areas of coverage and minimum water supply requirements shown in the manufacturer datasheet. This Horizontal Sidewall sprinkler head has a maximum working pressure of 175 PSI (12 BAR) and connects to wet piping systems.

Viking™ (VK630) Horizontal Sidewall Sprinkler Installation and Other Information

The VK630 Horizontal Sidewall Sprinkler is installed surface mounted or recessed in the Horizontal Sidewall orientation. Refer to the manufacturer data sheet for installation instructions with the approved Viking™ accessories. During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional installation and storage information.

Available finish options include Brass, Chrome, White, and Black.
Temperature options include 135F (57C), 155F (68C), 175F (79C).

White and Black Polyester Finish are cULus Listed as corrosion resistant.

The VK630 listed wrenches include the approved Viking™ Standard Sprinkler Wrench (21475M/B) and the Viking™ Recessed Horizontal Sidewall Sprinkler Wrench (13655W/B). Add the correct wrench for your VK630 Horizontal Sidewall installation!

The VK630 listed escutcheons include the Viking™ E-1, E-2, and E-3 Recessed Escutcheons.
Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools.

Available Viking™ VK630 Horizontal Sidewall Sprinklers & Listed Accessories:

Viking™® VK630 Extended Coverage Horizontal Sidewall Sprinkler | QR | 8.0K | Brass | 135F | 3/4 in. NPT | 13500AA
Viking™® VK630 Extended Coverage Horizontal Sidewall Sprinkler | QR | 8.0K | Brass | 155F | 3/4 in. NPT | 13500AB
Viking™® VK630 Extended Coverage Horizontal Sidewall Sprinkler | QR | 8.0K | Brass | 175F | 3/4 in. NPT | 13500AD

Viking™® VK630 Extended Coverage Horizontal Sidewall Sprinkler | QR | 8.0K | Chrome | 135F | 3/4 in. NPT | 13500FA
Viking™® VK630 Extended Coverage Horizontal Sidewall Sprinkler | QR | 8.0K | Chrome | 155F | 3/4 in. NPT | 13500FB
Viking™® VK630 Extended Coverage Horizontal Sidewall Sprinkler | QR | 8.0K | Chrome | 175F | 3/4 in. NPT | 13500FD

Viking™® VK630 Extended Coverage Horizontal Sidewall Sprinkler | QR | 8.0K | White | 135F | 3/4 in. NPT | 13500MA/W
Viking™® VK630 Extended Coverage Horizontal Sidewall Sprinkler | QR | 8.0K | White | 155F | 3/4 in. NPT | 13500MB/W
Viking™® VK630 Extended Coverage Horizontal Sidewall Sprinkler | QR | 8.0K | White | 175F | 3/4 in. NPT | 13500MD/W

Viking™® VK630 Extended Coverage Horizontal Sidewall Sprinkler | QR | 8.0K | Black | 135F | 3/4 in. NPT | 13500MA/B
Viking™® VK630 Extended Coverage Horizontal Sidewall Sprinkler | QR | 8.0K | Black | 155F | 3/4 in. NPT | 13500MB/B
Viking™® VK630 Extended Coverage Horizontal Sidewall Sprinkler | QR | 8.0K | Black | 175F | 3/4 in. NPT | 13500MD/B

Wrenches:
Viking™ Standard Sprinkler Wrench | 21475M/B | Pendent
Viking™ Pendent/Domed HSW | Recessed/Concealed | 13655W/B

Escutcheons:
Viking™ E-1 Escutcheon | E1ST
Viking™ E-2 Escutcheon | E2ST
Viking™ E-3 Escutcheon | E3ST

Reviews
No reviews yet
Product Alternatives