Viking™ VK650 Flush Institutional Pendent Sprinkler | Extended Coverage | QR | 5.6K | Chrome | 205F | 19876FE

SKU:
VK650CH205
Manufacturer Part Number:
19876FE
$135.51
Data Sheet Product Data Sheet

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
VK650CH205
Manufacturer Part Number:
19876FE
Manufacturer:
Viking™
SIN:
VK650
Model:
Institutional
Head Type:
Institutional Pendent
Finish:
Chrome
Finish Detail:
Polished Chrome
Size:
1/2 in.
Size Detail:
1/2 in. NPT Sprinkler
K Factor:
5.6K
Response Type:
Quick Response (QR)
Temperature:
205F
Heat Element:
Fusible Link
Coverage:
Extended Coverage
Material:
Brass Frame, Copper Deflector
Corrosion Resistant:
No
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
No
Occupancy Type:
Light Hazard
Maximum Working Water Pressure:
175 PSI
Escutcheon Type:
Flush
Sourced Location:
USA
Length:
2.15 in. (54.61 mm)
Width:
2.15 in. (54.61 mm)
Height:
1.48 in. (37.592 mm)
Weight:
0.51 lbs. (0.23 kg)
System Type:
Wet

Viking™ VK650 Flush Institutional Pendent Sprinkler | Extended Coverage | QR | 5.6K | Chrome | 205F | 19876FE | QRFS™ | Pendent

Viking™ VK650 Flush Institutional Pendent Sprinkler | Extended Coverage | QR | 5.6K | Chrome | 205F | 19876FE | QRFS™ | Pendent
Viking™ VK650 Flush Institutional Pendent Sprinkler | Extended Coverage | QR | 5.6K | Chrome | 205F | 19876FE | QRFS™ | Front
Viking™ VK650 Flush Institutional Pendent Sprinkler | Extended Coverage | QR | 5.6K | Chrome | 205F | 19876FE | QRFS™ | Deflector
Viking™ VK650 Flush Institutional Pendent Sprinkler | Extended Coverage | QR | 5.6K | Chrome | 205F | 19876FE | QRFS™ | Pair
Viking™ VK650 Flush Institutional Pendent Sprinkler | Extended Coverage | QR | 5.6K | Chrome | 205F | 19876FE | QRFS™ | Hero
Overview

Viking™ Institutional Extended Coverage QR Pendent (VK650) Fire Sprinkler Head

Sprinkler Identification Number (SIN): VK650
This Extended Coverage Institutional Pendent Sprinkler features a Chrome finish and a 205F (97C) temperature.

This Viking™ Institutional Pendent Fire Sprinkler is a extended coverage, flush pendent sprinkler, activating at 205F (97C) with a 5.6 K-Factor, and is rated for Light hazard occupancies. Each pendent head features heat-sensitive fusible link assembly, standard 1/2 in. NPT threads, and a brass frame with copper deflector.

This is a quick response, extended coverage, institutional sprinkler with a maximum working water pressure of 175 PSI. The VK650 Institutional Sprinkler features a tamper-resistant design, making it a safe and effective choice for use with concealed piping in various institutional mental health occupancies, correctional facilities, or other settings where flush, tamper-resistant sprinklers may be required.

Using a heat-activated fusible link assembly, this automatic fire sprinkler opens when ambient temperatures reach the sprinkler's listed activation temperature, drenching the area surrounding a fire to keep it in its place of origin. The VK650 is installed flush using one of Viking™’s 3 in. or 4 in. escutcheon plates, leaving exposed only a small portion of the fusible link assembly to ensure the timely activation of the fire sprinkler. Refer to the manufacturer data sheet for installation instructions with the approved Viking™ escutcheon(s).

Viking™ Flush Institutional Fire Sprinkler (VK650) Sprinkler Head Listings and Approvals

Each institutional sprinkler is made by Viking™, a global leader in fire protection manufacturing for nearly 100 years. When installed properly, this VK650 fire sprinkler head maintains listings and approvals from cULus (Category VKKW). Refer to the datasheet for listings and approvals in specific temperatures and/or applications.

The Viking™ Institutional Pendent Sprinkler VK650 is designed for NFPA 13. Apply the listed areas of coverage and minimum water supply requirements as shown in the Approval Chart of the datasheet. This flush pendent sprinkler head has a maximum working pressure of 175 PSI (12.1 BAR) and connects to fixed fire protection systems (wet, dry, deluge, or pre-action systems).

Viking™ Institutional (VK650) QR Pendent Sprinkler Installation and Other Information

During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional installation and storage information.

Available finishes include Chrome, White, and Grey. Temperature options include 165F (68C) and 205F (97C).
Finish and temperature combinations available in the “Options” section at the top of this product page.

The listed VK650 accessories include the approved Viking™ Institutional Wrench (PN. 22847MB) and the approved Viking™ Institutional 3 in. (PN. 23196-) or 4 in. (PN. 23197-) Escutcheon(s). Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools.

Available Viking™ VK650 Flush Institutional Pendent Sprinklers:
VK650CH165 | Viking™ VK650 Flush Institutional Pendent Sprinkler | Chrome | 165F | 19876FC
VK650CH205
| Viking™ VK650 Flush Institutional Pendent Sprinkler | Chrome | 205F | 19876FE

VK650WH165 Viking™ VK650 Flush Institutional Pendent Sprinkler | White | 165F | 19876MC/W
VK650WH205
| Viking™ VK650 Flush Institutional Pendent Sprinkler | White | 205F | 19876ME/W

VK650GR165 | Viking™ VK650 Flush Institutional Pendent Sprinkler | Grey | 165F | 19876MC/RAL9006
VK650GR205 | Viking™ VK650 Flush Institutional Pendent Sprinkler | Grey | 205F | 19876ME/RAL9006

Available Viking™ Institutional Escutcheons:
3 in. Outer Diameter:
12-VK-23196-CH
| Viking™ Flush Institutional Escutcheon | Polished Chrome | 3 in. OD | 1/2 in. Sprinkler | 23196F
12-VK-23196-WH
| Viking™ Flush Institutional Escutcheon | Painted White | 3 in. OD | 1/2 in. Sprinkler | 23196M/W
12-VK-23196-GR
| Viking™ Flush Institutional Escutcheon | Painted Grey | 3 in. OD | 1/2 in. Sprinkler | 23196M/RAL9006
4 in. Outer Diameter:
12-VK-23197-CH
| Viking™ Flush Institutional Escutcheon | Polished Chrome | 4 in. OD | 1/2 in. Sprinkler | 23197F
12-VK-23197-WH
| Viking™ Flush Institutional Escutcheon | Painted White | 4 in. OD | 1/2 in. Sprinkler | 23197M/W
12-VK-23197-GR
| Viking™ Flush Institutional Escutcheon | Painted Grey | 4 in. OD | 1/2 in. Sprinkler | 23197M/RAL9006

Reviews
No reviews yet
Product Alternatives