Grooved 90 Degree Elbow | Short | GemLock™ | 6 in. | Style F105

SKU:
53-GM-90-SH-260000
Manufacturer Part Number:
400-210-03860
$59.99
  • Buy 3 - 14 and get 2.5% off
  • Buy 15 or above and get 7.5% off

FAST SHIPPING: In stock items ship SAME DAY if ordered before 3PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
53-GM-90-SH-260000
Manufacturer Part Number:
400-210-03860
Manufacturer:
GemLock™
Fitting:
Elbow
Style:
Style F105
Size:
6 in.
Size Detail:
6 in. Grooved x 6 in. Grooved
UL Listed:
Yes
FM Approved:
Yes
Rated Working Water Pressure:
300 PSI
Finish:
Orange
Length:
5.5 in. (139.7 mm)
Width:
5.5 in. (139.7 mm)
Weight:
9.06 lb. (4.11 kg)
Angle:
90 Degree
Fitting Pattern:
Short

GemLock™ Short Pattern 90 Degree Elbow | 6 in. Style F105 | Hero

GemLock™ Short Pattern 90 Degree Elbow | 6 in. Style F105 | Hero
GemLock™ Short Pattern 90 Degree Elbow | 6 in. Style F105 | Markings 1
GemLock™ Short Pattern 90 Degree Elbow | 6 in. Style F105 | Markings 2
GemLock™ Short Pattern 90 Degree Elbow | 6 in. Style F105 | Side
GemLock™ Short Pattern 90 Degree Elbow | 6 in. Style F105 | Family
Play Button
Overview

GemLock™ Grooved 90 Degree Short Elbow

This Grooved x Grooved 90 Degree Short Pattern Elbow features two 6 in. connections to be used in grooved pipe systems, including specifically fire sprinkler piping systems, allowing for proper water flow and fast installation. This elbow is available in the following sizes:

1-1/2 in., 2 in., 2-1/2 in., 3 in., 4 in., 6 in., 8 in.

You can select your preferred size from the “Options” section at the top of this product page. Accessories compatible with this grooved elbow include other GemLock™ grooved fittings and Pipe Joint Lubricant.

GemLock™ is a leader in the grooved pipe market – their grooved fittings are reliable and faster to install than welding threading, or flanging, resulting in drastically lower installation costs comparatively. GemLock™ grooved fittings provide a clean, consistent, and strong connection for optimal water flow when used with compatible products. The Victaulic™ pipe fitting equivalent to this product is the Victaulic™ Grooved Elbow 90 Degree FireLock Style 001. Gruvlok fitting equivalent: 7450 90 Degree Elbow.

GemLock™ Short Pattern Grooved Fittings are designed to Fire Protection Industry standards and sized to improve flow. These Short Pattern Fittings are made of durable, high-strength ductile iron conforming to ASTM A536, with every lot metallurgically tested for compliance. Pressure Ratings of GemLock™ Grooved Short fittings are tested to a maximum operating pressure of 300 PSI*.

*Maximum pressure includes surges and maximum end loads from all internal and external forces, to which a joint could be subject under normal working conditions. This rating provides a nominal safety factor of 1.5 times working pressure based on standard weight steel pipe. Maximum working pressure may be subjected to a one-time field test of 1.5 times the figures indicated.

GemLock™ Grooved 90 Degree Short Elbow Listings, Approvals, and Other Information

Each Short Pattern 90 Degree Elbow is made by GemLock™, a New York-based manufacturer of fire sprinkler grooved pipe fittings, HVAC, plumbing and grooved tubing. All GemLock™ grooved piping system fittings are UL Listed and FM Approved. Refer to installations and groove specifications when assembling any grooved product. Usage of GemLock™ Short Pattern fittings with Style 5, 12, and 25 couplings should be evaluated properly due to bolt pad interference of couplings.

All GemLock™ Ductile Iron fittings conform to ASTM A536 Grade 65-45-12. Allowable pipe end separation is for cut groove pipe for roll groove; figures will be one-half of the values listed at time of initial pressurization.

Certain GemLock™ product families and all GemLock™ Grooved fittings 8 in. and larger are only available upon request and are not available for immediate shipping.

Reviews
No reviews yet
Product Alternatives