SALE

Reliable™ CCP Cover Plate | Domed | 1/2 in. Adjustment | Bronze | 135F

SKU:
RLCCP12FZ135
$29.47
$20.63
  • Buy 10 - 99 and get 5% off
  • Buy 100 - 499 and get 15% off
  • Buy 500 or above and get 30% off

FAST SHIPPING: In stock items ship SAME DAY if ordered before 3PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
Finish:
Brass
Finish Detail:
Finished Bronze
Temperature:
135F
Adjustment:
1/2 in.
UL Listed:
Yes
FM Approved:
Yes
Outer Diameter:
3-3/4 in.
Inner Diameter:
2-3/16 in.
Model:
CCP
Manufacturer:
Reliable™

Reliable™ CCP Cover Plate | Domed | 1/2 in. Adjustment | Bronze | 135F

Reliable™ CCP Cover Plate | Domed | 1/2 in. Adjustment | Bronze | 135F
Reliable™ CCP Cover Plate | Domed | 1/2 in. Adjustment | Bronze | 135F
Reliable™ CCP Cover Plate | Domed | 1/2 in. Adjustment | Bronze | 135F
Reliable™ CCP Cover Plate | Domed | 1/2 in. Adjustment | Bronze | 135F
Reliable™ CCP Cover Plate | Domed | 1/2 in. Adjustment | Bronze | 135F
Reliable™ CCP Cover Plate | Domed | 1/2 in. Adjustment | Bronze | 135F
Reliable™ CCP Cover Plate | Domed | 1/2 in. Adjustment | Bronze | 135F
Data & Resources
Overview

Finished Bronze 135F (57C) Cover Plate Assembly for Reliable™ CCP Fire Sprinklers activates at 135F (57C) to facilitate timely activation of fire sprinkler heads with temperatures rated at 135F (57C) to 175F (79C). This model has a 1/2 in. adjustment.

Sprinkler Identification Numbers (SIN) for this Finished Bronze 135F (57C) Cover Plate Assembly for Reliable™ CCP Fire Sprinklers include:

  • R3511
  • R3513
  • R3516
  • R4842
  • R5314
  • R5714
  • R5942
  • R7618
  • RA1414
  • RA2345
  • RA2614
  • RA3045
  • RA3311
  • RA3313
  • RA3316

This Finished Bronze 135F (57C) Cover Plate Assembly for Reliable™ CCP Fire Sprinklers is listed by UL and cULus. When this Finished Bronze fire sprinkler cover plate reaches a specified temperature the solder holding the plate's decorative exterior on the frame melts, and the two separate. Cover plates in stock finishes other than Finished Bronze are available on our site, and custom-finished may be available by special order - call us at 888-361-6662 or click here to contact us.

For many cover plates, the rated temperature is at least 20F (6.7C) cooler than the sprinkler head's activation temperature, which ensures that the cover plate detaches early enough to allow the sprinkler to activate on time. However, each manufacturer's product line varies slightly and cover plate temperatures may be closer to or further away from the fire sprinkler's activation temperature. Use only the cover plate approved by the manufacturer for your specific sprinkler.

Fire Sprinkler Helpful Tips:

Tip 1: When replacing cover plates it is important to purchase replacements from the same manufacturer as the fire sprinkler. Each manufacturer's plate is a little different in size, color, and so on. The manufacturer and temperature of a cover plate is printed on the base of the plate. To view this information, remove the cover plate. Most cover plates are either twist off or pull off.

Tip 2: Any modifications or replacements to a fire sprinkler system should be performed by qualified professionals.

Tip 3: National Fire Protection Association (NFPA) guidelines state that spare fire sprinkler heads and a wrench should be accessible at all times in a facility with a commercial fire sprinkler system installed. Often, state regulations also apply. Check with your local fire department.

Tip 4: All fire sprinkler systems should be visually inspected (often) and professionally inspected (annually).

Reviews
No reviews yet
Product Alternatives