CPVC Coupling | Reducing Adapter, Threaded | Slip x Threaded | 3/4 in. x 1/2 in. F NPT

SKU:
TCPVCTA21

No reviews yet Write a Review
$3.25
CPVC Straight Terminal Adapter | 3/4" Slip x 1/2" FNPT Outlet
CPVC Straight Terminal Adapter | 3/4" Slip x 1/2" FNPT Outlet
Slip Inlet View of CPVC Straight Terminal Adapter | 3/4" Slip x 1/2" FNPT Outlet
Side View of CPVC Straight Terminal Adapter | 3/4" Slip x 1/2" FNPT Outlet
Inside View of CPVC Straight Terminal Adapter | 3/4" Slip x 1/2" FNPT Outlet

  • Buy 50 - 199 and get 5% off
  • Buy 200 or above and get 15% off

Frequently Bought Together:

CPVC Straight Terminal Adapter | 3/4" Slip x 1/2" FNPT Outlet
Inc. Tax
Ex. Tax

Overview

3/4 in. Slip x 1/2 in. FNPT CPVC Straight Terminal Adapter is a corrosion-resistant CPVC thermoplastic fitting for use with fire sprinkler pipe. This CPVC straight terminal adapter has a 3/4 in. slip inlet and a brass 1/2 in. FNPT connection, facilitating the installation of a fire sprinkler head.

This straight adapter is designed to slide over CPVC pipe and fix permanently using an approved adhesive. Each 3/4 in. Slip x 1/2 in. FNPT CPVC Straight Terminal Adapter is made in the USA by Thermafit Industries, Inc., a California-based manufacturer of plumbing and fire sprinkler pipe fittings. This straight terminal adapter has a working pressure rating of 175 PSI at 150F (65C) and is suitable for installation in NFPA 13, NFPA 13D, and NFPA 13R systems where allowed by state and local law.

3/4 in. Slip x 1/2 in. FNPT CPVC Straight Terminal Adapter is intended for use in light hazard NFPA 13 occupancies, residential NFPA 13R occupancies, and home fire sprinkler systems in accordance with NFPA 13D. This product is UL-listed for use in wet-pipe automatic fire sprinkler systems in combination with UL-listed CPVC products.

3/4 in. Slip x 1/2 in. FNPT CPVC Straight Terminal Adapter is backed by Thermafit's ten-year warranty from the date of shipment. Consult Thermafit's installation manual for minimum curing times, compatible adhesives, and friction loss allowances. Not suitable for out

Dimensions

CPVC Straight Terminal Adapter Dimensions

  • A: 1.058 in.
  • B: 1.046 in.
  • L: 2.040 in.
  • M: 1.046 in. +/- 0.004
  • N: 1.000 in. +/- 0.004
  • Wall Thickness: 0.396 in.

Specifications

Material:
CPVC
Pipe Fitting Type:
Coupling
UL Listed/FM Approved:
No

Data & Resources

Reviews

No reviews yet

Customers Also Viewed

3/4" (19.05 mm) CPVC Slip x Slip x Slip Tee | Sprinkler Pipe Fitting 3/4" (19.05 mm) CPVC Slip x Slip x Slip Tee | Sprinkler Pipe Fitting

CPVC Tee | Slip x Slip x Slip | 3/4 in.

SKU : TCPVCST2

$1.25
3/4 in. (19.05 mm) CPVC Slip x Slip x Slip Tee is a corrosion-resistant CPVC thermoplastic fitting for use with fire sprinkler pipe. This CPVC tee features three 3/4 in. (19.05 mm) female socket...
3/4" (19.05 mm) CPVC 90-Degree Slip x Slip Elbow 3/4" (19.05 mm) CPVC 90-Degree Slip x Slip Elbow

CPVC Elbow, 90 Degree | Slip x Slip | 3/4 in.

SKU : TCPVC9E2

$0.83
3/4 in. CPVC 90-Degree Slip x Slip Elbow is a corrosion-resistant CPVC thermoplastic fitting for use with fire sprinkler pipe. This 90-degree CPVC elbow features two 3/4 in. (19.05 mm) female socket...
3/4" (19.05 mm) CPVC 45-Degree Slip x Slip Elbow 3/4" (19.05 mm) CPVC 45-Degree Slip x Slip Elbow

CPVC Elbow, 45 Degree | Slip x Slip | 3/4 in.

SKU : TCPVC4E2

$1.54
3/4 in. CPVC 45-Degree Slip x Slip Elbow is a corrosion-resistant CPVC thermoplastic fitting for use with fire sprinkler pipe. This 45-degree CPVC elbow features two 3/4 in. (19.05 mm) female socket...
CPVC Glue | One-Step Cement | 1 Quart CPVC Glue | One-Step Cement | 1 Quart

CPVC Glue | One-Step Cement | 1 Quart

SKU : TFI1QCPGLUE

$21.95
CPVC Glue forms a water-tight seal between CPVC pipes, fittings, couplings, elbows, and other components used in the construction of fire sprinkler systems. This quart of one-step solvent cement...