CPVC Reducing Tee 1-1/4 in. x 1 in. x 1-1/4 in. | Viking BlazeMaster™ | V5011R-159

SKU:
51-BL-TE-171617
Manufacturer Part Number:
V5011R-159
$16.24

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
51-BL-TE-171617
Manufacturer Part Number:
V5011R-159
Manufacturer:
Viking™
Brand:
BlazeMaster™
Chemical Composition:
Chlorinated Polyvinyl Chloride (CPVC)
Fitting:
Tees
Finish:
Orange
Size:
1-1/4 in. x 1 in. x 1-1/4 in.
UL Listed:
Yes
FM Approved:
Yes
Rated Working Water Pressure:
175 PSI
Rated Working Water Temperature:
150F
Weight:
0.28 lb. (0.12 kg.)

CPVC Reducing Tee | 1-1/4 in. x 1 in. x 1-1/4 in. | Blazemaster | V5011R-159

CPVC Reducing Tee | 1-1/4 in. x 1 in. x 1-1/4 in. | Blazemaster | V5011R-159
CPVC Reducing Tee | 1-1/4 in. x 1 in. x 1-1/4 in. | Blazemaster | V5011R-159
CPVC Reducing Tee | 1-1/4 in. x 1 in. x 1-1/4 in. | Blazemaster | V5011R-159
CPVC Reducing Tee 1-1/4 in. x 1 in. x 1-1/4 in. | Viking BlazeMaster™ | V5011R-159
Play Button
Overview

Viking BlazeMaster™ 1-1/4 in. x 1 in. x 1 in. SXSXS CPVC Tee

This Viking BlazeMaster™ Tee is manufactured from high-quality, corrosion-resistant chlorinated polyvinyl chloride (CPVC) thermoplastic. Designed specifically for fire sprinkler systems, this SXSXS CPVC fitting is used to connect sections of fire sprinkler pipe and maintain proper system flow. Viking CPVC fire sprinkler products provide a range of advantages over traditional metal systems, including smoother interior surfaces for superior hydraulics, ease of handling, and quicker assembly using readily available tools. BlazeMaster™ CPVC technology has a proven performance history of more than 40 years in fire protection. This fitting features SXSXS and is suitable for both new system installations and approved retrofits.

Applications and Compatibility

This Tee is intended for use in wet pipe fire sprinkler systems for light hazard occupancies per NFPA 13, 13R, and 13D standards, when approved by the Authority Having Jurisdiction (AHJ). It is compatible with SDR 13.5 CPVC fire sprinkler pipe and is designed in accordance with: ASTM F438 for sizes 3/4 in. to 1-1/4 in. (Schedule 40) ASTM F439 for sizes 1-1/2 in. to 3 in. (Schedule 80)

Listings and Approvals

Viking BlazeMaster™ CPVC fittings are: UL Listed (VIWT and VIWT7.EX15419) FM Approved (Class 1635) LPCB Red Book Listed (Certificate 1558a to LPS 1260-2.2) NSF/ANSI 61 and NSF/ANSI 372 Certified for potable water use (Lead Free)

Pressure & Temperature Ratings

Rated Working Pressure: 175 PSI (1,200 kPa) Maximum Service Temperature: 150°F (65°C)

Installation & Storage Guidelines

Install Viking BlazeMaster™ CPVC products using UL-listed and/or FM-approved solvent cements. These products should be stored indoors in original packaging, away from direct sunlight and chemical contaminants such as edible oils, petroleum products, and materials containing plasticizers (e.g., electrical tape or wire insulation). Failure to follow proper storage and installation practices may result in product damage, voided warranty, or system failure.

Warnings

Do not expose this product to incompatible chemicals, including oils, esters, ketones, or petroleum-based substances. Consult chemical compatibility documentation before use.