Grooved Mechanical Tee | GemLock™ | 4 in. x 1 in. | Style 35 | 400-210-02270

SKU:
53-GM-MT-GV-241600
Manufacturer Part Number:
400-210-02270
$20.60
Data Sheet Product Data Sheet

Select Variation

Product not eligible for free ground shipping offer.

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
53-GM-MT-GV-241600
Manufacturer Part Number:
400-210-02270
Manufacturer:
GemLock™
Fitting:
Mechanical Tee
Material:
Ductile Iron
Gasket Material:
EPDM
Style:
Style 35
Finish:
Orange Painted
Size:
4 in. x 1 in.
Size Detail:
4 in. Run Size x 1 in. Grooved Outlet
Maximum Working Water Pressure:
300 PSI
UL Listed:
Yes
FM Approved:
Yes
Weight:
3.23 lbs.
Outlet Type:
Grooved

Grooved Mechanical Tee | GemLock™ | 4 in. x 1 in. | Style 35 | 400-210-02270

Grooved Mechanical Tee | GemLock™ | 4 in. x 1  in. | Style 35 | 400-210-02270
Grooved Mechanical Tee | GemLock™ | 4 in. x 1  in. | Style 35 | 400-210-02270
Grooved Mechanical Tee | GemLock™ | 4 in. x 1  in. | Style 35 | 400-210-02270
Grooved Mechanical Tee | GemLock™ | 4 in. x 1  in. | Style 35 | 400-210-02270
Overview

GemLock™ Grooved Mechanical Tee

GemLock™ is a leader in the grooved pipe market – their grooved fittings are reliable and faster to install than welding threading, or flanging, resulting in drastically lower installation costs comparatively. GemLock™ grooved fittings provide a clean, consistent, and strong connection for optimal water flow when used with compatible products. The Victaulic™ pipe fitting equivalent to this product is the Victaulic™ Mechanical Tee Grooved Style 920. Gruvlok fitting equivalent: 7046 Grooved Mechanical Tee. The Style 35 has replaced the Style 15.

Mechanical Branchlet provides a direct branch connection at any location along the pipe run without welding. A hole cut along the center line of pipe will receive the hole locator collar to secure the outlet. A pressure responsive EPDM gasket molded to suit the run pipe insures leak tight joints. Cross type connections can be made utilizing upper housings only. Refer to the datasheet for Hole Diameter.

GemLock™ Grooved Mechanical Tees are made of durable, high-strength ductile iron conforming to ASTM A536, with every lot metallurgically tested for compliance. Pressure Ratings of GemLock™ Grooved Mechanical Tees are tested to a maximum operating pressure of 300 PSI*.

*Maximum pressure includes surges and maximum end loads from all internal and external forces, to which a joint could be subject under normal working conditions. This rating provides a nominal safety factor of 1.5 times working pressure based on standard weight steel pipe. Maximum working pressure may be subjected to a one-time field test of 1.5 times the figures indicated.

GemLock™ Grooved Mechanical Tee Listings, Approvals, and Other Information

Each Grooved Mechanical Tee is made by GemLock™, a New York-based manufacturer of fire sprinkler grooved ductile iron pipe fittings, HVAC, plumbing and grooved tubing. All GemLock™ grooved piping system fittings are UL Listed and FM Approved. Refer to installations and groove specifications when assembling any grooved product.

The gasket included with this product is constructed of specially compounded rubber polymers with low compressions set properties. The sealing efficiency of gaskets is such that the gasket forms an initial seal as it is stretched over the pipe ends. As the housing segments are installed, the gasket seals to create a leak-tight joint. The seal becomes even stronger from internal downward pressure on the lips of the gasket. The gasket seals under vacuum conditions up to 10inHg (-0.35 Bar). Gaskets are pre-lubricated at a minimum but should be lubed more for ease of assembly and optimal performance. For lubricant, refer to the accessories on this product page.

All bolts and nuts used in GemLock™ fittings are either oval neck track bolts constructed of Carbon Steel conforming to ASTM A183 with minimum tensile strength of 110,00 PSI or square neck carriage bolts made of Steel with Zinc Coating (Galvanized) conforming to ASTM A446 with 120,000 PSI minimum tensile strength.  Nuts are made of Carbon Steel conforming to ASTM A194.

All GemLock™ Ductile Iron mechanical grooved tees conform to ASTM A536 Grade 65-45-12. Allowable pipe end separation is for cut groove pipe for roll groove; figures will be one-half of the values listed at time of initial pressurization.

 

Reviews
No reviews yet
Product Alternatives