Round Pitot Gauge Kit with Notched and Straight Plastic Blades

SKU
02PITU
Round Pitot Gauge Kit with Notched and Straight Plastic Blades contains everything needed to measure water flows from fire hose nozzles, fire hydrants, and other water-based systems. Includes round pitot handle, 1 notched and 1 straight plastic blade, 2 1/2" (63.5 mm) gauge, foam-lined case, and sealing tape.
As low as $149.95
Part NumberConstruction (Tube)Tube LengthTotal Length
02PITUNickel Plated Brass8" (203 mm)10.5" (267 mm) with Notched Blade
Gauge SizeGauge Pressure & Gauge Pressure RangeGauge AccuracyOptional Features
2 1/2" (63.5 mm) Dial with 1/4" (6.35 mm) NPT Pressure Connection200 PSI, Choice of 8 Gauge Ranges1% Mid-Range AccuracyGauge NIST Certification
Kit ContentsAvailability
Round Pitot Handle, Plastic Notched Blade, Plastic Straight Blade, Pressure Gauge, Thread Seal Tape, Foam-Lined CaseUsually ships within 24 hours

Product Description

Pitot Gauge Kit with Plastic Blades is the most accurate, efficient and economical way to measure discharge from fire hose nozzles, fire hydrants, or other open orifices. Includes two plastic pitot blades—one straight blade and one notched blade—and a machined-brass round-handle tube.

Brass quick-connect fittings join the included gauge to the tube with stainless steel locking balls, making it easy to rotate the gauge with little torque required.

This Pitot Gauge Kit with Plastic Blades includes a 2 1/2" (63.5 mm) dial with a 1/4" (6.35 mm) NPT pressure connection. Gauge readings can be converted to GPM using a pitot gauge theoretical discharge conversion table.

Each gauge is liquid-filled and available in one of eight dial ranges:

Dial RangesMajor #'d GraduationsMinor GraduationsSmallest Graduations
0-60 psi1051
0-100 psi10-2
30-0-100 psi10-2
0-160 psi20102
0-200 psi20102
30-0-200 psi20102
0-300 psi50105
30-0-300 psi50105

The pitot tube in each Pitot Gauge Kit with Plastic Blades has a built-in air chamber to negate any need for an air bleeder. This chamber also dampers gauge needle movements under pulsation for enhanced accuracy.

The Pitot Gauge Kit with Plastic Blades also includes a roll of thread seal tape, and a foam-lined carrying case. For $40 more, the included 2 1/2" (63.5 mm) pressure gauge arrives tested and certified to standards established by the National Institute of Standards and Technology (NIST) to meet the exacting standards of accuracy demanded by clients in the U.S. Navy, Army, and aviation industries, amongst others.

More Information

Pitot Gauge Theoretical Discharge Conversion Table. Used to convert PSI readings to GPM. Conversion accuracy depends on an accurate measurement of outlet size and the nozzle or outlet coefficient. 