Reliable™ RA1314 Pendent Sprinkler | SR | 5.6K | Chrome | 286F | F56P3CN

SKU:
RA1314CH286
Manufacturer Part Number:
F56P3CN
$17.16
Data Sheet Product Data Sheet

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
RA1314CH286
Manufacturer Part Number:
F56P3CN
Manufacturer:
Reliable™
SIN:
RA1314
Model:
F156
Head Type:
Pendent
Finish:
Chrome
Finish Detail:
Chrome
Size:
1/2 in.
Size Detail:
1/2 in. NPT Sprinkler
K Factor:
5.6K
Response Type:
Standard Response (SR)
Temperature:
286F
Heat Element:
Glass Bulb
Coverage:
Standard Coverage
Material:
Brass Frame, Brass/Bronze Deflector
Corrosion Resistant:
No
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
Yes
Occupancy Type:
Light/Ordinary Hazard
Maximum Working Water Pressure:
250 PSI
Escutcheon Type:
Recessed or Surface Mounted
Sourced Location:
USA
Length:
1.00 in. (25.4 mm)
Width:
1.00 in. (25.4 mm)
Height:
2.25 in. (57.15 mm)
Weight:
0.14 lbs. (0.07 kg)
System Type:
Wet

Reliable™ RA1314 Pendent Sprinkler | SR | 5.6K | Chrome | 286F | F56P3CN | QRFS™ | Hero

Reliable™ RA1314 Pendent Sprinkler | SR | 5.6K | Chrome | 286F | F56P3CN | QRFS™ | Hero
Reliable™ RA1314 Pendent Sprinkler | SR | 5.6K | Chrome | 286F | F56P3CN | QRFS™ | Front
Reliable™ RA1314 Pendent Sprinkler | SR | 5.6K | Chrome | 286F | F56P3CN | QRFS™ | Deflector
Overview

Reliable™ Model F156 Standard Response Pendent (RA1314) Fire Sprinkler Head

Sprinkler Identification Number (SIN): RA1314

This Reliable™ Model F156 Pendent Fire Sprinkler is a standard coverage pendent sprinkler, activating at 286F (141C) with a 5.6 K-Factor, and is rated for Light and Ordinary Hazard occupancies. Each pendent head features a heat-sensitive glass bulb assembly, standard 1/2 in. NPT threads, and a brass frame with a brass/bronze deflector.

This is a standard response, standard coverage, pendent sprinkler with a maximum working water pressure of 250 PSI (17 BAR). The RA1314 Model F156 Sprinkler features a durable and low-profile appearance.

Using a heat-activated glass bulb assembly, this automatic fire sprinkler opens when ambient temperatures reach 286F (141C), drenching the area surrounding a fire to keep it in its place of origin. The RA1314 is installed exposed or recessed using one of Reliable™’s adjustable F1 escutcheons, offering flexibility of installation, inspection, and testing without shutting down your fire sprinkler system. Refer to the manufacturer data sheet for installation instructions with the approved Reliable™ escutcheon(s).

Reliable™ Model F156 Fire Sprinkler RA1314 Sprinkler Head Listings and Approvals

Each F156 sprinkler is made by Reliable™, a global leader in fire protection manufacturing for over 100 years. When installed properly, this RA1314 fire sprinkler head maintains listings and approvals: cULus, FM, LPCB, VdS, EC, UKCA
Refer to the datasheet for listings and approvals in specific temperatures and/or applications.

When using Reliable™ Pendent Sprinkler RA1314 for systems designed to NFPA 13, apply the listed areas of coverage and minimum water supply requirements shown in the manufacturer datasheet. This pendent sprinkler head has a maximum working pressure of 250 PSI (17 BAR) and connects to wet piping systems.

RA1314 Pendent Sprinkler Installation and Other Information

During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional installation and storage information.

This pendent sprinkler features a Chrome finish and 286F (141C) temperature. Available finish options include Brass, Chrome, White, and Black. White Polyester Finish (White), and Black Polyester Finish (Black) are UL Listed as corrosion resistant. Temperature options include 135F (57C), 155F (68C), 200F (93C), 286F (141C), 360F (182C). Finish and temperature combinations available in the “Options” section at the top of this product page.



Available Reliable™ RA1314 Pendent Sprinklers:

Reliable™ RA1314 Pendent Sprinkler | SR | 5.6K | White | 135F | F56P0W
Reliable™ RA1314 Pendent Sprinkler | SR | 5.6K | Brass | 135F | F56P0BN
Reliable™ RA1314 Pendent Sprinkler | SR | 5.6K | Chrome | 135F | F56P0CN

Reliable™ RA1314 Pendent Sprinkler | SR | 5.6K | White | 155F | F56P1WN
Reliable™ RA1314 Pendent Sprinkler | SR | 5.6K | Brass | 155F | F56P1BN|
Reliable™ RA1314 Pendent Sprinkler | SR | 5.6K | Chrome | 155F | F56P1CN

Reliable™ RA1314 Pendent Sprinkler | SR | 5.6K | Brass | 175F | F56P5BN
Reliable™ RA1314 Pendent Sprinkler | SR | 5.6K | Chrome | 175F | F56P5CN
Reliable™ RA1314 Pendent Sprinkler | SR | 5.6K | White | 175F | F56P5W

Reliable™ RA1314 Pendent Sprinkler | SR | 5.6K | Brass | 200F | F56P2BN
Reliable™ RA1314 Pendent Sprinkler | SR | 5.6K | Chrome | 200F | F56P2CN
Reliable™ RA1314 Pendent Sprinkler | SR | 5.6K | White | 200F | F56P2WN

Reliable™ RA1314 Pendent Sprinkler | SR | 5.6K | Brass | 286F | F56P3BN
Reliable™ RA1314 Pendent Sprinkler | SR | 5.6K | Chrome | 286F | F56P3CN
Reliable™ RA1314 Pendent Sprinkler | SR | 5.6K | White | 286F | F56P3WN

Reliable™ RA1314 Pendent Sprinkler | SR | 5.6K | Brass | 360F | F56P6BN
Reliable™ RA1314 Pendent Sprinkler | SR | 5.6K | Chrome | 360F | F56P6CN
Reliable™ RA1314 Pendent Sprinkler | SR | 5.6K | White | 360F | F56P6WN

Reviews
No reviews yet
Product Alternatives