Reliable™ SWC Cover Plate | Bright Brass | 135F | 3-5/16 in. OD | 6887131605

SKU:
11-RA-SWC-BP135
Manufacturer Part Number:
6887131605
$49.86
Data Sheet Product Data Sheet

Select Variation

Want It Customized?
Please Note: Cover plates are designed for specific sprinkler heads. Size alone does not guarantee compatibility. To ensure the correct fit, please use our Sprinkler Cover Plate Finder Tool.

  • Buy 50 - 99 and get 2.5% off
  • Buy 100 or above and get 7.5% off

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
11-RA-SWC-BP135
Manufacturer Part Number:
6887131605
Manufacturer:
Reliable™
Model:
SWC
Installation Type:
Push On or Thread On
Adjustment:
1/2 in.
Outer Diameter:
3-5/16 in.
Inner Diameter:
2-3/16 in.
Finish:
Brass
Finish Detail:
Bright Brass
Temperature:
135F
Corrosion Resistant:
No
UL Listed:
Yes
FM Approved:
No
Length:
3.31 in. (84.07 mm)
Width:
3.31 in. (84.07 mm)
Height:
2.5 in. (63.5 mm)
Weight:
0.31 lb. (0.14 kg)

Image may not reflect exact finish | QRFS™

Image may not reflect exact finish | QRFS™
Shown in white finish | QRFS™
Play Button
Overview

Reliable™ SWC Domed Horizontal Sidewall Fire Sprinkler Cover Plate

Reliable™ SWC Bright Brass Fire Sprinkler Domed Cover Plate with 135F (57C) activation temperature. This fire sprinkler cover works with certain Reliable™/RASCO concealed sidewall fire sprinklers.  The SWC domed cover facilitates timely activation of these Reliable™ concealed sidewall fire sprinkler heads with a temperature rating of 135F (57C) or 165 (74C). The outer diameter of this cover is 3-5/16 in. This domed horizontal sidewall cover has a maximum adjustment of 1/2 in. This Reliable™ Model SWC Cover features a finished brass plate to go along with a copper plated steel skirt and steel springs.

The Reliable™ SWC cover plate is a conical concealed cover plate used with compatible horizontal sidewall sprinklers.  It provides a push-on or thread on connection to the sprinkler. This cover plate is available in six finishes. These finishes include White Painted, Chrome, Black Painted, Off White Painted, Bright Brass, and Satin Chrome.  Along with these base finishes, for an additional fee Reliable™ will custom paint this cover in any finish you prefer, so long as the paint is from Benjamin Moore or Sherwin-Williams. Contact QRFS™ customer support for more details.

Reliable™ SWC Cover Plate Sprinkler Head Compatibility and Listings

This Sprinkler Head Cover Plate from Reliable™ may be listed by UL, FM, and/or other organizations depending on the sprinkler it’s being used with. It meets the requirements of a sprinkler assembly per NFPA 13, where approved by the local Authority Having Jurisdiction. It installs by simply pushing or threading the cover into the sprinkler’s frame. The recommended hole diameter when installing sprinkler heads using this cover is 2-5/8 in. and protrudes 1-5/8 in. from the ceiling.

To remove your existing cover plate, gently twist the cover to the left while applying downward pressure by pulling gently as you turn.

When this fire sprinkler cover plate reaches its specified temperature of 135F (57C) or 165 (74C), the solder holding the plate's decorative exterior on the frame melts, and the two separate. For many cover plates, the rated temperature is at least 20F (6.7C) cooler than the sprinkler head's activation temperature, which ensures that the cover plate detaches early enough to allow the sprinkler to activate on time. However, each manufacturer's product line varies slightly, and cover plate temperatures may be closer to or further away from the fire sprinkler's activation temperature. Use only the cover plate approved by the manufacturer for your specific sprinkler.

Reliable™ SWC Cover Plate Finishes, Temperatures, and Listed Accessories

This Reliable™ SWC fire sprinkler dome is readily available in White Painted, and can be ordered in Chrome, Black Painted, Off White Painted, Bright Brass, and Satin Chrome upon request. It is available in two temperatures: 135F (57C) or 165F (74C). This domed cover plate can be adjusted up to 1/2 in. You can choose from all the available options by selecting from the dropdown at the top of the page. Find all related products in the Frequently Bought Together section above.

This Sprinkler Cover Plate fits the following Reliable™ concealed sprinkler heads:

  • R3531
  • R6834
  • RA0362
  • RA1564
  • RA3331
  • RA4862
  • RA5962