Scorpion Portable Controller for Point & ASD Smoke Detector Testers
Scorpion is the solution for testing smoke detectors in buildings with hard-to-access detectors, such as those found in Point and Aspirating Smoke Detector (ASD) systems. Scorpion offers a product for both systems to ensure all smoke detectors can be operational – regardless of location. Scorpion makes testing smoke detectors in lift shafts, warehouses, ceiling voids and secure areas as simple as testing detectors within easy reach.
The Scorpion Portable Controller is used to activate installed Point or ASD Scorpion Testing systems. It uses the SCORP 25 Access point included in each Testing kit to connect remotely, allowing for portable use over multiple sites. Powered by the Solo 770 Battery Batton, available separately.
Point Smoke Detectors vs. Aspirating Smoke Detectors (ASD)
ASD (Aspirating Smoke Detection) and point smoke detectors are two distinct types of smoke detection systems, each with its advantages and applications. Point smoke detectors are the more traditional and widely used type, typically found in residential and commercial buildings. These detectors are installed individually at specific locations, such as ceilings, and rely on smoke particles physically entering their sensing chamber to trigger an alarm. Point smoke detectors are cost-effective and suitable for smaller spaces, but they might have limitations in detecting smoke in large or inaccessible areas.
On the other hand, ASD smoke detectors offer a more advanced and sensitive approach to smoke detection. By actively aspirating air from a network of sampling points, ASD systems can detect smoke particles at their earliest stages, providing an early warning for potential fire hazards. The continuous air sampling reduces the risk of false alarms caused by environmental factors, making ASD systems well-suited for critical environments like data centers, clean rooms, and industrial facilities. While ASD smoke detectors might have higher upfront costs and more complex installations, their ability to cover larger areas and provide early detection makes them ideal for applications where safety and reliability are paramount.