Tyco™ Style F Institutional Fire Sprinkler Escutcheon
Tyco™ P/N: 56-314-4-010
(Institutional Sprinkler Head Sold Separately)
Tyco™ RAVEN Style F Escutcheon in Painted White Finish and 3 in. Outer Diameter, for use with Tyco™ RAVEN Flush Institutional Sprinkler Heads. This One-piece Tyco™ Escutcheon features a Carbon Steel metal design and Slip-On installation, allowing the escutcheon to slide easily onto the sprinkler adapter and body while holding it securely in place. A properly installed escutcheon looks great while ensuring on-time sprinkler activation & compliance!
This Tyco™ Style F Escutcheon is available in multiple finishes, matching the finish of your Tyco™ Institutional Sprinkler. Available finishes include Painted White, Painted Grey, and Chrome. These escutcheons are also available in two materials, Carbon Steel and Stainless Steel. These escutcheons must be installed with the manufacturer-defined institutional fire sprinkler heads. See list below to check for sprinkler head compatibility.
The Tyco™ Style F Institutional Escutcheon ring guarantees proper sprinkler head activation by covering the gap left by a hole saw when a fire sprinkler is installed. Keep your system compliant by using the listed fire sprinkler escutcheon for your sprinkler.
Tyco™ Institutional Escutcheon Compatibility, Listings, and Other Information
The Tyco™ Style F Escutcheon is designed for use with a variety of Tyco™ Flush Institutional Sprinkler Heads. When installed properly, these flush escutcheons provide a low-profile appearance that complements the flush, tamper-resistant design of your RAVEN Institutional Sprinkler Head.
When combined with a listed sprinkler head, this flush escutcheon may carry listings from UL, FM, and/or other organizations, depending on the sprinkler it is installed with. Refer to the specific sprinkler’s technical datasheet for specific approvals. Whether you’re installing a new fire sprinkler system or just need a fire sprinkler escutcheon replacement, be sure that it works with your model sprinkler!
Tyco™ Style F Escutcheons for RAVEN Institutional Spriklers:
Tyco™ Style F Escutcheon for RAVEN Institutional Sprinklers | Carbon Steel | White | 3 in. Diameter | 56-314-4-010
Tyco™ Style F Escutcheon for RAVEN Institutional Sprinklers | Carbon Steel | Grey | 3 in. Diameter | 56-314-7-010
Tyco™ Style F Escutcheon for RAVEN Institutional Sprinklers | Stainless Steel | White | 3 in. Diameter | 56-318-4-010
Tyco™ Style F Escutcheon for RAVEN Institutional Sprinklers | Stainless Steel | Grey | 3 in. Diameter | 56-318-7-010
Tyco™ Style G Escutcheons for RAVEN Institutional Spriklers:
Tyco™ Style G Escutcheon for RAVEN Institutional Sprinklers | Carbon Steel | White | 4 in. Diameter | 56-312-4-010
Tyco™ Style G Escutcheon for RAVEN Institutional Sprinklers | Carbon Steel | Grey | 4 in. Diameter | 56-312-7-010
Tyco™ Style G Escutcheon for RAVEN Institutional Sprinklers | Stainless Steel | White | 4 in. Diameter | 56-319-4-010
Tyco™ Style G Escutcheon for RAVEN Institutional Sprinklers | Stainless Steel | Grey | 4 in. Diameter | 56-319-7-010
This Sprinkler Escutcheon fits the following Tyco™ RAVEN Institutional sprinkler heads:
TY3281
TY3381
TY3282
TY3382