Tyco™ TY3311 Model TY-L Horizontal Sidewall Sprinkler | SR | 5.6K | Brass | 165F | 53-113-1-165

SKU:
TY3311BR165
Manufacturer Part Number:
53-113-1-165
$63.61
$35.91
  • Fire Sprinkler Wrench | Tyco™ W-Type 9 | Standard | 56-000-1-849 | QRFS™ | Hero
  • Fire Sprinkler Wrench | Tyco™ W-Type 10 | Recessed | 56-000-1-948 | Hero
  • Tyco™ Style 20 Escutcheon | Chrome | 1/2 in. Sprinkler | QRFS™ | Hero
  • Tyco™ Style 20 Escutcheon | White | 1/2 in. Sprinkler | QRFS™ | Hero
  • Tyco™ Style 20 Escutcheon | Brass | 1/2 in. Sprinkler | QRFS™ | Hero

FAST SHIPPING: In stock items ship SAME DAY if ordered before 3PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
TY3311BR165
Manufacturer Part Number:
53-113-1-165
Manufacturer:
Tyco™
SIN:
TY3311
Model:
TY-L
Head Type:
Horizontal Sidewall
Finish:
Brass
Finish Detail:
Natural Brass
Size:
1/2 in.
Size Detail:
1/2 in. NPT Sprinkler
K Factor:
5.6K
Response Type:
Standard Response (SR)
Temperature:
165F
Heat Element:
Fusible Link
Coverage:
Standard Coverage
Material:
Brass Frame, Bronze Deflector
Corrosion Resistant:
No
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
Yes
Occupancy Type:
Light, Ordinary Hazard
Maximum Working Water Pressure:
175 PSI
Escutcheon Type:
Surface Mounted
Sourced Location:
USA
Length:
1.57 in. (39.878 mm)
Width:
1.57 in. (39.878 mm)
Height:
2.63 in. (66.802 mm)
Weight:
0.3 lbs. (0.14 kg)

Tyco™ TY3311 Model TY-L Horizontal Sidewall Sprinkler | SR | 5.6K | Brass | 165F | 53-113-1-165 | QRFS™ | Hero

Overview

Tyco™ Model TY-L Horizontal Sidewall Fire Sprinkler Head

Sprinkler Identification Number (SIN): TY3311

This Horizontal Sidewall sprinkler features a Brass finish and a 165°F (73°C) temperature.

This Tyco™ Model TY-L Horizontal Sidewall Fire Sprinkler is a standard response, standard coverage sprinkler, activating at 165°F (73°C) with a 5.6 K-Factor, and is rated for light, ordinary hazard occupancies. Each Horizontal Sidewall head features a heat-sensitive fusible link assembly, standard 1/2 in. NPT threads, and a Brass frame with Bronze deflector.

This is a standard response, standard coverage, Horizontal Sidewall sprinkler with a maximum working water pressure of 175 PSI. Using a heat-activated fusible link assembly, this automatic fire sprinkler opens when ambient temperatures reach the listed activation temperature, effectively containing the spread of fire.

The TY3311 is installed as a Horizontal Sidewall or recessed Horizontal Sidewall using one of Tyco™’s approved Style 20 escutcheons. Refer to the manufacturer data sheet for installation instructions with the approved Tyco™ escutcheon(s).

Tyco™ Horizontal Sidewall Fire Sprinkler (TY3311) Sprinkler Head Listings and Approvals

Each sprinkler head is made by Tyco™, a global leader in fire protection manufacturing for nearly 100 years. When installed properly, this TY3311 maintains the following listings and approvals: UL, C-UL, FM
Refer to the datasheet for listings and approvals in specific temperatures and/or applications.

The Tyco™ Horizontal Sidewall Sprinkler TY3311 is designed for NFPA 13. Apply the listed areas of coverage and minimum water supply requirements as shown in the datasheet. This Horizontal Sidewall sprinkler head has a maximum working pressure of 175 PSI (12.1 BAR) and connects to wet pipe fire protection systems.

Tyco™ TY3311 Automatic Fire Sprinkler Installation and Accessories

During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional installation and storage information.

  • 280F Not Approved for Recessed Installation

Listed TY3311 Accessories include:

Recessed Escutcheons:

  • Style 20 

Sprinkler Wrenches:

  • W-Type 9 Standard Sprinkler Wrench
  • W-Type 10 Recessed Sprinkler Wrench

Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page.

Available Sprinklers:

165F Brass 5.6K 1/2 in. NPT - TY3311BR165
165F Chrome 5.6K 1/2 in. NPT - TY3311CH165

212F Brass 5.6K 1/2 in. NPT - TY3311BR212
212F Chrome 5.6K 1/2 in. NPT - TY3311CH212

280F Brass 5.6K 1/2 in. NPT - TY3311BR280
280F Chrome
5.6K 1/2 in. NPT - TY3311CH280