Viking™ Loose Trim J-1 Alarm Check Valve | Vertical | Flange x Groove | 3 in. NPT | Brass | 11428

SKU:
70-VK-AC-LTB-FG-2222
Manufacturer Part Number:
11428
$2,255.71

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
70-VK-AC-LTB-FG-2222
Manufacturer:
Viking™
Manufacturer Part Number:
11428
Size:
3 in.
Size Detail:
3 in. NPT Alarm Check Valve
Valve Type:
Alarm Check Valve
Trim Type:
Loose Trim
Body Material:
Brass
Connection Type:
Flanged x Grooved
Finish:
Red
Installation:
Vertical
Weight:
20.41 lbs (9.26 kg.)
Maximum Working Pressure:
300 PSI
Minimum Working Temperature:
32F (0 C)
UL Listed:
Yes
FM Approved:
Yes
Other Listings:
cULus Listed, ABS Certified, NYC, LPCB, VdS, CE Certified

Viking™ Loose Trim J-1 Alarm Check Valve | Vertical | Flange x Groove | 3 in. NPT | Brass | 11428

Overview

Viking™ J-1 Alarm Check Valve (Loose Trim, Vertical Trim)

The Viking™ J-1 Alarm Check Valve (Loose Trim) is a dependable alarm check valve designed for wet pipe fire sprinkler systems and intended for vertical installation. Its purpose is to prevent reverse water flow while also initiating alarm operation when sprinkler flow occurs. It is made of Brass and has an 3 in. NPT  Flange x Grooved connection. It's finish is red. During a fire event, the valve opens to allow water to move into the sprinkler system and simultaneously supplies water/pressure to alarm lines to trigger connected alarm devices, providing both fire suppression support and rapid notification.

This Loose Trim configuration is supplied as an unassembled trim package in the box rather than pre-piped on the valve, and the valve is provided without switches (pressure/alarm switches must be ordered separately). The trim must be installed exactly as shown in the manufacturer’s trim arrangement, and all trim components used must be listed for a maximum working water pressure of 300 psi (20.7 bar). A water motor alarm configuration requires a strainer, and for variable pressure water supplies, a retard chamber is required (order separately). The trim also includes provisions for a non-interruptible pressure switch connection intended only for constant-pressure systems; that alarm port cannot be shut off until flow ceases, and a retard chamber may not be installed on that specific non-interruptible port.

The J-1 Alarm Check Valve is rated for a maximum working water pressure of 300 psi and uses Flanged x Grooved connections to support common installation practices. The trim package includes 300 psi pressure gauges, with optional higher-range gauges available where system pressure warrants, supporting proper inspection and testing practices.

The Viking™ J-1 Alarm Check Valve (Loose Trim) carries key third-party approvals and certifications, including UL Listed and FM Approved, along with cULus Listed, ABS Certified, NYC acceptance, LPCB, VdS, and CE Certified listings—supporting use across a wide range of jurisdictions and specifications.

Reviews
No reviews yet
Product Alternatives