Viking™ Domed & Dry Pendent Cover Plate | Ivory | 135F | 3-1/8 in. OD | 12381MA/I

SKU:
11-VK-12381-IV135
Manufacturer Part Number:
12381MA/I
$50.42
Data Sheet Product Data Sheet

Select Variation

Want It Customized?
Please Note: Cover plates are designed for specific sprinkler heads. Size alone does not guarantee compatibility. To ensure the correct fit, please use our Sprinkler Cover Plate Finder Tool.

  • Buy 50 - 99 and get 2.5% off
  • Buy 100 or above and get 7.5% off

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
11-VK-12381-IV135
Manufacturer Part Number:
12381MA/I
Manufacturer:
Viking™
Model:
Domed & Dry Pendent
Label Number:
12382A
Installation Type:
Push On
Adjustment:
1/2 in.
Outer Diameter:
3-1/8 in.
Inner Diameter:
2-3/8 in.
Finish:
Ivory
Finish Detail:
Ivory Painted
Temperature:
135F
Corrosion Resistant:
No
UL Listed:
Yes
FM Approved:
Yes
Length:
3.13 in. (79.5 mm)
Width:
3.13 in. (79.5 mm)
Height:
1.75 in. (44.45 mm)
Weight:
0.21 lb. (0.1 kg)

Viking™ Domed & Dry Pendent Cover Plate | Ivory | 135F | 3-1/8 in. OD | 12381MA/I | Hero | QRFS™

Viking™ Domed & Dry Pendent Cover Plate | Ivory | 135F | 3-1/8 in. OD | 12381MA/I | Hero | QRFS™
Viking™ Domed & Dry Pendent Cover Plate | Ivory | 135F | 3-1/8 in. OD | 12381MA/I | Label | QRFS™
Play Button
Overview

Viking™ Domed & Dry Pendent Fire Sprinkler Cover Plate

Viking™ Domed and Dry Pendent (Label No: 12382A) Ivory Fire Sprinkler Cover Plate with 135F (57C) activation temperature. This fire sprinkler cover works with certain Viking™ pendent fire sprinklers, including certain dry pendents.  The Domed cover facilitates timely activation of these Viking™ fire sprinkler heads with a temperature rating of 135F (57C) or 165F (74C). The outer diameter of this cover is 3-1/8 in. This Viking™ cover plate is available with a 1/2 in. adjustment.

The Viking™ Domed & Dry Pendent cover plate is a cover plate used with compatible sprinklers.  It provides a push-on connection into the sprinklers cup. This cover plate is available in five finishes. These finishes include Painted White, Polished Chrome, Polished Brass, Ivory Painted, and Black Painted.  Along with these base finishes, for an additional fee Viking™ will custom paint this cover in any finish you prefer. Contact QRFS™ customer support for more details.

Viking™ Domed & Dry Cover Plate Sprinkler Head Compatibility and Listings

This Sprinkler Head Cover Plate from Viking™ may be listed by UL, FM, and/or other organizations depending on the sprinkler it’s being used with. It meets the requirements of a sprinkler assembly per NFPA 13, where approved by the local Authority Having Jurisdiction. It installs by simply pushing the cover into the sprinkler’s frame, and can be adjusted up to 1/2 in. The recommended hole diameter when installing sprinkler heads using this cover is 2-5/8 in.

To remove your existing cover plate, gently twist the cover to the left while applying downward pressure by pulling gently as you turn.

When this fire sprinkler cover plate reaches its specified temperature of 135F (57C) or 165 (74C) the solder holding the plate's decorative exterior on the frame melts, and the two separate. For many cover plates, the rated temperature is at least 20F (6.7C) cooler than the sprinkler head's activation temperature, which ensures that the cover plate detaches early enough to allow the sprinkler to activate on time. However, each manufacturer's product line varies slightly, and cover plate temperatures may be closer to or further away from the fire sprinkler's activation temperature. Use only the cover plate approved by the manufacturer for your specific sprinkler.

Viking™ Domed & Dry Pendent Cover Plate Finishes, Temperatures, and Listed Accessories

These Viking™ Domed & Dry Pendent sprinkler system cover plates are available in Painted White, Polished Chrome, Polished Brass, Ivory Painted, and Black Painted. It is available at a temperature of 135F (57C) or 165F (74C). You can choose from all the available options by selecting from the dropdown at the top of the page. Find all related products in the Frequently Bought Together section above.

Viking™ is a leader in the fire protection manufacturing industry, with a variety of sprinkler heads, escutcheons, and cover plates.

This Sprinkler Cover Plate fits the following Viking™ concealed sprinkler heads:

  • VK102
  • VK190
  • VK192
  • VK194
  • VK196
  • VK202
  • VK302
  • VK352
  • VK353
  • VK614
  • VK616
  • VK618
Reviews
No reviews yet
Product Alternatives